ZEBRONICS AD801 Contactless Infrared Thermometer User Manual

June 5, 2024
ZEBRONICS

zebronics logo

ZEBRONICS AD801 Contactless Infrared Thermometer

Scope of Application

Used by families and medical departments when measuring body temperature

Precautions

  • Please read this manual carefully before use, and make sure the battery is installed
  • It is forbidden to immerse the forehead temperature gun in a, liquid, and is forbidden to use it in an excessively high or low temperature environment a long time.
  • It is forbidden to collide, fall, mix with sharp objects, and dismantle by yourself.
  • Do not use in strong electromagnetic interference environment
  • Put the forehead temperature gun out of the reach of children.
  • The measurement results can’t replace the doctor’s diagnosis.

Features

  • Contactless infrared Thermometer
  • Easy to use device with Large LCD Display
  • High Temperature Indication
  • Intelligent 3 color backlight prompt to identify fever
  • High Accuracy & Rapid Operation

Product Performance, Major Structural Components

Specifications
  • Measurement mode: Non-Contact
  • Display size: H 28.1mm,W 25.3mm+/- 0.2 mm.
  • Range of measurement : 34°C – 42°C
  • Measuring distance : 3cm – 5cm
  • Measuring time : 1 s
  • Accuracy : ±0.2°C
  • Memory data : 32 sets
  • Relative humidity : :::;85%
  • Barometric pressure : 70kPa – 106kPa
  • Auto Shutdown : 30s
  • Operating ambient: 16° c – 40° c
  • temperature: DC 3V (AAA battery x 2)
  • Power Source: 43 x 77 x 149 mm
  • Product Dimensions(Wx D x H)
  • Product Weight: 110g (without battery)

Function

This product measures the body temperature by collecting the infrared thermal radiation from the human forehead. Its operation is simple and sanitary, and its measurement is fast and accurate. The user only needs to point the detector head at the forehead and press the trigger button. In one second, the user can quickly and accurately measure the body temperature, which can be used by families and medical departments.

Installation and Usage Instructions

  1. Infrared Detector
  2. LCD
  3. Down
  4. Up
  5. Mode
  6. Trigger Button
  7. Battery Cover

Instructions for Use

Display Icon Definition
Switch Between Body and Object Temp

Short press the Mode button to switch between body temp and object temp.

Check Previously Measured Temperature

Short press the Up/Down button to check previously measured temperature.

Adjust Temperature

Long press the Mode button to enter F1 setting visible on display. Use the Up and Down buttons (short press) and adjust the temperature value gradually.

Adjust Maximum Temperature Alert

From main display, long press the Mode button to enter F1 setting, now short press the Mode button to enter F2 setting. Short press the Up/Down buttons to increase or decrease the maximum temperature alert. (By default, the maximum temperature alert is set at 38°C. You can either decrease till 37°C or increase till 39°C, gradually. If the temperature reaches the specified value, an alert will be notified. (°C); to (°F) < > (°F) to (0() From main display, long press Mode button to enter F1 setting, short press Mode button to enter F2 mode and repeat short press again to enter F3 setting for (0C)(°F) adjustment. Now short press Up/Down button to change (0C)(°F) unit. Tone On/Off: Enter F4, then short press Up/Down button to On or Off the tone. This can be identified with icon on display.
Note:

  • Power ON the display with the trigger button and then proceed for the temperature measurement.
  • Adjust temperature option is recommended to be done only when required. It is not advised to change the values unnecessarily, as it can affect the measurement values.
  • Confirm that the measurement mode above the screen is body temperature mode (non object temperature mode).
  • Align the forehead temperature gun probe with the middle of the forehead and keep it vertical, with a distance of about 3-5 cm. Press the trigger button to start the measurement. After about 1 second, the screen display the measurement value.
Warm Tips
  1. Before and after use, please keep the sensor and probe cavity clean.
  2. Please place the forehead temperature gun in a temperature stable environment for use. When ambient temperature changes greatly (eg. from indoor to outdoor), please place for about thirty minutes after measurement.
  3. Do not begin to measure body temperature immediately after measuring the temperature of an object at very high or very low temperature. Please place it for ten minutes.
  4. When the measurement object comes from a place that is quite different from the measured ambient temperature, it should stay in the test environment for at least five minutes.
  5. Try not to measure in the forehead blowing, drenching water, sweating, coating, smear cosmetics, etc.

Object Surface Temperature Measurement

  • Adjust the temperature measurement mode to the object temperature.
  • Aim the thermometer probe at the measuring target and keep it vertical, the distance is about 3-5 cm press the measuring key, display the temperature after about 1 second, or device will turn off automatically after 30 seconds.
Warm Tips
  1. The range of measurement of the temperature measurement mode of the object 0°(-100°(.
  2. This function measures the object surface temperature and does not represent the object core temperature.
  3. The emissivity of different materials may be different (refer to the emissivity of materials), and the measured temperature will deviate slightly from the actual temperature.
  4. When the measured value is less than 0°C, bright red backlight, display ‘Lo’.
  5. When the measurement is higher than 100°C, bright red backlight, display ‘Hi’.

Product Maintenance and Maintenance Methods

  • Because the product is a reusable device, please pay attention to the cleaning process after use.
  • Please keep the inner cavity of sensor and probe clean, otherwise it will affect the measurement accuracy.
  •  Surface cleaning: wipe dirt with clean soft cloth or cotton stick with a little medical spray.
  • Cleaning inner cavity of the sensor and probe: gently wipe the inner cavity of the head or the top of the sensor with a clean soft cloth or cotton stick with a little medical sprinkler. When the alcohol is completely volatile.

Storage Conditions, Methods

Device must be kept clean and kept in dry place. Don’t put the electronic forehead temperature gun in a place with electric shock. Do not store the electronic forehead temperature gun in an extreme temperature environment above 55°C ro below -10°C and humidity above 85%.

Transport Conditions, Methods

The transportation process should prevent rain, heavy fall and so on, can not be transported in the extreme temperature environment above 55° ( or below -10° c humidity above 85%.
ISO 9001:2015 Certified Company
www.zebronics.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ZEBRONICS User Manuals

Related Manuals