KASTA KMCAP-CT-W Clipsal30 Mech -Hpm Linea & Excel Instruction Manual
- June 5, 2024
- KASTA
Table of Contents
KASTA KMCAP-CT-W Clipsal30 Mech -Hpm Linea & Excel
APP Installation
Visit www.kasta.com.au or your app store to download the free KASTA app. iOS: requires iOS 9.0 or later. Android: requires Android 4.4 or later. Devices must support Bluetooth 4.0
Important Safety Information
- This product must be installed by a licensed electrician in accordance with all the requirements of AS/NZS 3000 (current edition) and other relevant Standards and Regulations. Electricity MUST be disconnected prior to installation. Failure to do so may result in serious injury and or loss of life.
- Indoor use only. Not suitable for damp or explosive environments.
- Complies to Australian Standards AS/NZS 60950.1:2015, AS/NZS CISPR 15.
- No user-serviceable parts inside.
FEATURES
- Mains powered curtain control module
- Compatible with standard bidirectional 4-wire motors (2 Active, 1 Neutral, 1 Earth).
- Single-phase 240AC max. or 24VDC max. power.
- Simple 7 wire connection – A, N, Com, Open, Close, S1, S2.
- Install in conjunction with an appropriately rated momentary action mechanism to S1 and S2.
- Can be paired with KASTA remote switches for either single button operation or two-button operation (8x maximum).
- Smart functions via phone/tablet with the app such as schedules, timers, scenes and groups.
- Built-in overvoltage and overcurrent protection.
- To prevent a reduction in Bluetooth ® signal strength, install away from metal objects.
FUNCTION SETUP
First, calibrate curtain using KASTA app.
S1 CONNECTION
ON/PAUSE: 1 CLICK
Open or pause curtain.
OPEN UNTIL RELEASED: LONG PRESS
Curtain opens until button is released. S2 CONNECTION
ON/PAUSE: 3 CLICKS
Close or pause curtain.
CLOSE UNTIL RELEASED: LONG PRESS
Curtain closes until button is released. S1, S2 CONNECTION or RESET BUTTON
**DELAY TO OFF: 3 CLICKS***
Curtain will automatically close after set time.
PAIRING MODE: 6 CLICKS
Enter pairing mode for multi-way control. Lights will pulse.
FACTORY RESET: 9 CLICKS
Restores all settings back to factory.
TECHNICAL SPECIFICATIONS
- Operating Temp: -20ºc to 40ºc
- Supply: 220-240V AC 50Hz
CONNECTION DIAGRAM