GENERAL PRECAUTION BEFORE USE
Thank you for purchasing the UNiKA PRO SERIES AUDIO INTERFACE. Before using,
please read this manual carefully and pay attention to every detail that you
must pay attention to. If you use a mixer to connect to this interface, please
turn off the mixer power and +48V phantom power before connecting, and then
turn on the power and phantom power after inserting the signal cables. For
passive models, please do not turn on the phantom power to avoid leakage or
damage the equipment. If using a model with a volume knob, turn the volume
knob to the minimum. During use, please do not plug or unplug the wires
arbitrarily to avoid signal loss. Please refer to the following instructions
for the soldering method of the plugs to ensure the expected level and keep
the signal smooth. If you need further installation or operation guidance,
please directly contact UNiKA’s dealer or distributor, or write to the
following mail address for help:
PRODUCT OVERVIEW
PRO 148 is an active single-channel DI box. Unlike traditional DI, PRO 148
uses +48V phantom power instead of the traditional 9V dry cell battery, so
users can use it on the mixer or external phantom power supply. Power is
supplied to PRO 148, the power supply circuit and the output signal line are
shared, and no additional power cord is required. The +48V indicator is set on
the upper cover. The +48V circuit specially selects the British OEP PT-4 pulse
transformer.
PRO 148 has a built-in UNiKA-PROTM EI30A10E 1+1:1+1 isolation transformer,
which has a special copper foil layer and a dedicated ground layer, which
allows this device to restore high signal/noise ratio and dynamic sound, and
can avoid unnecessary leakage caused by radio frequency interference, ground
interference and potential difference. PRO 148 is especially suitable for
electronic musical instruments, recording studios and fixed installation
projects by using mixers.
The PRO 148 uses a balanced/unbalanced combo socket on the input, and a TRS
through out is convenient for musician to pass the direct signal to the
instrument amplifier. In addition, it is equipped with a 0/-20dB attenuation
switch and LED indicator, which is suitable for various types of audio signals
with high and low impedance. The output terminal is also equipped with a
GND/LIFT button to quickly eliminate ground noise.
CAUTION
This product has undergone rigorous inspection before leaving the factory. If
customers encounter failures during use, please contact your local dealer or
distributor for replacement or repairing, do not disassemble the case or
replace parts by yourself, which will invalidate the warranty.
For details, please refer to the warranty regulations in the enclosed warranty
card, and fill in the details, and get a valid stamp or signature of the
dealer or distributor.
PARAMETER TEST CONDITIONS
In the development and manufacturing process, Audio Precision’s 2700 series
and 500 series are used to test and verify electrical characteristics.
FEATURES
- Power by external +48V phantom power
- Built-in UNiKA-PROTM EI30A10E isolation transformer
- Use British OEP PT-4 1:1 audio pulse transformer in phantom power circuit
- +48V status indicator on the upper cover
- The input socket uses Combo jack
- Use TRS jack as through out terminal
- At 0dB input, the set load impedance is 260KΩ, which can clearly show the high frequency overtones, harmonic and graininess of electric guitars or electric bass
- 50Ω ultra-low impedance output, suitable for various types of mixers and pre-amp equipment
- There is 0dB/-20dB input signal attenuation switch with status indicator
- The output is equipped with a GND/LIFT switch
APPEARANCE PARTS & FUNCTIONS
-
Signal output: XLR terminal, isolated balanced output of the transformer, need to turn on +48V phantom power supply for PRO 148 proper working after connecting to the mixer.
-
Output grounding/floating switch: when the switch is not pressed, the first pin (PIN-1) of XLR is grounded. PIN-1 will be disconnected from ground after pressing. This button should depend on the system. Used in the situation, in order to isolate the ground loop noise or leakage.
-
+48V phantom power indicator: When ISO OUT receive +48V phantom power, the indicator will be shinning the blue color.
-
Signal input: One combo jack be able to input balance and unbalance signal by TRS/TS and XLR plug.
-
Input attenuation switch: Provide 0/-20dB two option, when inputting signals of various impedances and levels.
It can be attenuated by 20dB to avoid overload or clipping. -
Attenuation active indicator: When the PAD attenuation switch is pressed (-20dB), the indicator light will be shinning the yellow color.
-
Signal through out: TRS socket, convenient for musicians musical instrument speakers or other DI and peripheral equipment.
ISO TRANSFORMER SCHEMATIC
PULSE TRANSFORMER SCHEMATIC
INPUT PAD ATTENUATION
The most widely used DI box is to connect electronic musical instruments,
sound source of A/V equipment and computers, convert their output signals into
balanced signals and then extend the transmission distance.
The most ideal state is to set the attenuator to 0dB position (button up) for
musical instrument. For some other type of signals, you can press the button
to make the signal is attenuated by 20dB to avoid clipping caused by signal
overload.
When the button is pressed, the PAD indicator on the right will light up.
POWER SUPPLY
PRO 148 is an active DI box and requires +48V phantom power. It can work normally when it is powered, but no additional power supply is required. Just use balanced wires to connect the device to the mixer’s input channel, and turn on the +48V power switch of the mixer, similar to connect a condenser microphone to the mixer.
When the +48V power supply is suppling properly, the +48V ACTIVE indicator light on the upper cover will light up.
Before connecting the device, do not turn on the +48V switch of the mixer.
ELIMINATING GROUND LOOP NOISE
The built-in channel independent balanced isolation transformer has solved the
potential difference leakage problem. When the system causes a ground loop due
to poor wiring, the noise can be eliminated through the GND/LIFT button.
The GND/LIFT button determines whether pin 1 of the output XLR is grounded,
grounded when it bounces,
and disconnected from ground when pressed.
CONNECTION GUIDE
SPECIFICATIONS
-
Circuit principle
Active low-noise op-amp with Transformer balance output -
Input connector
1 x Combo -
Thru connector
1 x TRS -
Input pad switch/indicator
0/-20dB push button with LED -
Power supply
+48V Phantom power through output connector with LED indicator on top cover -
Output connector
1 x Male XLR through ISO Transformer -
Output GND/LIFT switch
Push button -
Input impedance
260KΩ / 0dB, 50KΩ/-20dB -
Output impedance
50Ω -
Max. input level before clipping
+ 10dB -
Max Output level
+ 10dB -
Frequency response
20Hz-20KHz, +0.3/+0.6dB -
S/N ratio @20Hz~20KHz un-weight
95dB
-
T.H.D. @1KHz 0dBV output
<0.02% -
Transformer Ratio
1:1+1:1 -
Chassis
1.6mm/1.2mm steel cabinet and chassis -
Surface finished
Durable complex painting -
Dimension (W x D x H)
78 x 124 x 46 mm -
Weight
0.56kg -
Shipping weight
0.59kg -
Packing per carton
20pc/12.40kg -
Shipping dimension per carton
305 X 283 X 195 mm
EU DECLARATION OF CONFORMITY
Equipment
- Product name: Single active direct box
- Model: PRO-148
- EAN Code: 4711064410181
Manufacturer
- Manufacturer: UNiKA Electronic Co.,Ltd.
- Address: 6F, No.168, Xinhu 2nd Roadn, Nei-Hu, Taipei, Taiwan
- This declaration of conformity is issued under the sole responsibility of the manufacturer.
- Object of the declaration, Product: Direct box for musical instrument and A/V device.
- The object of the declaration described in point 4 is in conformity with the relevant Union harmonisation legislation2014/30/EU The Electromagnetic Compatibility Directive
- 6. References to the relevant harmonised standards used, or references to the specifications in relation to which conformity is declared: EMI
- EN 55032:2015: IEC 61000-4-3:2006+A1:2007+A2:2010
- EN 61000-3-3:2014: IEC 61000-4-42012
- EN 61000-3-3:2013: IEC 61000-4-5:2014+A1:2017
- EMS: IEC 61000-4-6:2013/CORE1:2015
- EN 55035:2017: IEC 61000-4-8:2009
- IEC 61000-4-2:2008 : IEC 61000-4-11:2-4+A1:2017
- Where applicable, the above equipment will be tested and revision of existent certificate by WH Technology Corp. (TAF Accreditatio Number:2954) for compliance With EMC requirements set forth in the EUROPEAN COUNCIL DIRECTIVE 2014/30/EU and the technical standards mentioned above. The results of testing in this report apply only to the product/system, which was tested. Other similar equipment will not necessarily produce the same results due to production tolerance.
- The technical file is available from the manufacturer at the address above