i Safe MOBILE MTC1A01 IS-TC1A.1 Thermal Imaging Camera User Manual
- June 5, 2024
- i safe MOBILE
Table of Contents
- OPERATING MANUAL SAFETY INSTRUCTIONS
- INTENDED USE
- DEVICE OVERVIEW
- SAFETY
- EX-RELEVANT SAFETY REGULATIONS
- USE IN EXPLOSION HAZARDOUS AREAS
- POSSIBLE USER ERRORS
- SCOPE OF DELIVERY
- INSTALLATION
- INITIATION
- MAINTENANCE/REPAIR
- STORAGE
- RECYCLING
- TRADEMARKS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MTC1A01 IS-TC1A.1 Thermal Imaging Camera
**User Manual
**
OPERATING MANUAL SAFETY INSTRUCTIONS
IS-TC1A.1
MODEL MTC1A01
Document No. 1048MM01REV01
Version: 2022-04-07 (c) 2022
i.safe MOBILE GmbH i.safe MOBILE GmbH
i_Park Tauberfranken 10
97922 Lauda-Koenigshofen
Germany
Tel. +49 9343 60148-0
info@isafe-mobile.com
www.isafe-mobile.com
Template: TEMPMM01REV10
This Operating Manual complies with these standards:
IEC 60079, IEC 82079, ANSI Z535.6 Diese ENGLISH
READ AND UNDERSTAND THE INSTRUCTIONS
PROTECT YOUR LIFE AND READ THE OPERATING MANUAL
This Operating Manual is part of the device IS-TC1A.1 (model MTC1A01). This
Operating Manual provides important information for the safe use of the
device.
- Before using the device, read this Operating Manual carefully and pay particular attention to the “Safety” section and the warnings highlighted with the warning symbol.
- Make sure you have access to this Operating Manual when you need it. You can find the current Operating Manual at www.isafe-mobile.com/en/support/downloads
- Follow all instructions given on the device and on the packaging.
- Follow local safety regulations.
INTENDED USE
The IS-TC1A.1 is an intrinsically safe, rugged Thermal Camera for use in
explosion hazardous areas of Zone 1/21 and 2/22, according to directive
2014/34/EU and IECEx 02. In combination with the IS530.1, the IS-TC1A.1 can
record and display temperatures.
Only use the device as described in this Operating Manual. Any other use is
considered improper and can lead to death, severe injuries, and damage to the
device.
The manufacturer i.safe MOBILE GmbH does not assume any liability for damage
caused by improper use. The warranty expires in the event of improper use.
WARRANTY
You can find the warranty conditions at www.isafe-
mobile.com/en/support/service
EU DECLARATION OF CONFORMITY
You will find the EU declaration of conformity at the end of this Operating
Manual or at www.isafe-mobile.com/en/support/downloads
EX MARKINGS
ATEX:
II 2G Ex ib IIC T4 Gb
II 2D Ex ib IIIC T135°C Db
EU Type Examination Certificate: EPS 21 ATEX 1 197 X
CE-designation: 2004
IECEx:
Ex ib IIC T4 Gb
Ex ib IIIC T135°C Db
IECEx Certificate: IECEx EPS 21.0060X
Temperature range:
-20°C … +60°C (EN/IEC 60079-0)
-10°C … +50°C (EN/IEC 62368-1)
Manufactured by:
i.safe MOBILE GmbH
i_Park Tauberfranken 10 97922
Lauda-Koenigshofen Germany
DEVICE OVERVIEW
- HOLDER: Holder for IS530.1.
- PLUG: Connecting IS530.1.
- MAGNETIC CHARGER PORT: Connection for the i.safe PROTECTOR 3.0 Magnetic Charger Cable (included in the IS530.1 package) for charging the IS530.1.
- CAMERA: Recording temperatures.
SAFETY
Read the “Safety” section of this Operating Manual carefully before using the
device. If you do not follow these instructions or do not understand them,
this could lead to death, severe injuries, and damage to the device.
USER
Only trained users who are qualified in the use of Ex devices in explosion
hazardous areas and who have read and understood this Operating Manual may use
this device.
EX-RELEVANT SAFETY REGULATIONS
Use of this device assumes that the operator observes the conventional safety regulations and has read and understood Operating Manual, Safety Instructions, and certificate. When used in explosion hazardous areas, the following Safety Instructions must also be complied with:
- To ensure the IP-protection, it has to be ensured that all gaskets are present and functional.
- There must be no large gap between the two halves of the housing.
- The device must be securely fastened to the ISM interface when used in ex-hazardous areas.
- The device may not be exposed to any aggressive acids or alkalis.
- The device may only be used in zones 1, 2, 21, or 22.
- Only accessories approved by i.safe MOBILE GmbH may be used.
USE IN EXPLOSION HAZARDOUS AREAS
DANGER
Improper use can result in death or severe injuries!
- Only use the device in explosion hazardous areas of zones 1/21 and 2/22 or outside of explosion hazardous areas.
- Only connect the device outside explosion hazardous areas to the ISM interface of the IS530.1. Before entering an explosion hazardous area with the device,
- make sure that the device is securely fastened to the ISM interface of the IS530.1,
- make sure that no gap can be seen between the two halves of the device,
- make sure the device is not damaged,
- make sure that all the labels on the device are readable. If you use the device in an explosion hazardous area, read and follow the instructions in the “Possible User Errors” section. Switch off the device immediately and leave the explosion hazardous area without delay if
- malfunctions occur on the device, · you have damaged the housing of the device,
- you have exposed the device to excessive loads,
- or the labels on the device are no longer readable.
POSSIBLE USER ERRORS
DANGER
Improper use can result in death or severe injuries! Follow the instructions
below:
- Do not modify the device structurally.
- Do not expose the device to high temperatures.
- Do not expose the device to strong UV radiation.
- Do not expose the device to processes with high electrical charges.
- Do not expose the device to aggressive acids or bases.
When working in explosion hazardous areas, please note:
- Do not loosen the screws on the device.
- Do not open any interface cover.
- Do not charge the IS530.1.
- Do not open the device.
- Do not damage the device.
SCOPE OF DELIVERY
Your device packaging contains the following:
1 x IS-TC1A.1
1 x Operating Manual Safety Instructions
1 x Screwdriver
INSTALLATION
DANGER
Improper use can result in death or severe injuries! Only connect the device
outside explosion hazardous areas to the ISM interface of the IS530.1.
- Unscrew the cover of the ISM interface (1) located on the IS530.1.
- Push the IS530.1 completely into the holder (2) of the device.
- Attach the plug on top of the ISM interface (3).
- Fix the plug by pressing the rounded end of the plug (4).
- Tighten the screw (5).
- Check whether the plug is correctly and firmly attached to the ISM interface.
- The device can now be used together with the IS530.1 in explosion hazardous areas.
INITIATION
NOTE: The following information applies to IS-TC1A.1 in combination with the IS530.1.
- Download and install the Seek Thermal application from the Google Playstore.
- Open the Seek Thermal application at the IS530.1 and you can start immediately.
CHARGING THE IS530.1
You can charge the IS530.1 via the magnetic charger port on the IS-TC1A.1.
DANGER
An incorrect procedure in explosion hazardous areas poses a risk of death or
severe injuries! Only charge the IS530.1 outside of explosion hazardous areas.
Do not charge the IS530.1 in the vicinity of flammable substances.
NOTICE
Incorrect charging can cause damage to the device.
- Follow the instructions in the,, Charging” section of the IS530.1 operating manual.
- Only charge the IS530.1 using the i.safe PROTECTOR 3.0 Magnetic Charger Cable (included in the IS530.1 package).
- Connect the i.safe PROTECTOR 3.0 Magnetic Charger Cable to the magnetic charger port on the IS-TC1A.1.
POSSIBLE DEVICE PROBLEMS
You can find information on possible device problems and how to rectify them
at www.isafe-mobile.com/en/support/service under the menu item “FAQ”. If you have any
further questions, please contact the i.safe MOBILE repair service at www
.isafe-mobile.com/en/support/service
MAINTENANCE/REPAIR
The device itself has no serviceable parts.
WARNING
Incorrect repairs present a risk of explosion or fire, which can result in
death or severe injuries! Do not open the device or carry out any repairs
yourself.
Contact the i.safe MOBILE repair service at www.isafe-
mobile.com/en/support/service
if the device is not working normally, if the device needs to be repaired or
if a replacement part is required.
RETURN SHIPMENT
Contact the i.safe MOBILE repair service at www.isafe-
mobile.com/en/support/service
DISTRIBUTION PARTNER
You can find the specialist distribution partner responsible for your country
at www.isafe-mobile.com/en/contact
CLEANING
NOTICE Incorrect cleaning can cause damage to the device. Please note the
following when cleaning:
Do not use chemical agents for cleaning. Clean the device with a soft,
moistened antistatic cloth.
STORAGE
NOTICE
Incorrect storage can cause damage to the device. Store the device at ambient
temperatures between +5 °C to +35 °C (41 °F to +95 °F) and a humidity between
10 % to 60 %.
RECYCLING
NOTICE
Incorrect disposal of electronic products, batteries, and packaging material
puts the environment at risk. Please note the following when disposing of
items:
- DO NOT throw away batteries with household waste.
- Always dispose of electronic products, batteries, and packaging material at the appropriate collection points. This way, you prevent uncontrolled waste disposal and promote the recycling of material resources.
You can obtain further information from regional waste disposal companies, state authorities, or the i.safe MOBILE service center responsible for your country or region at www.isafe-mobile.com/en/support/service
TRADEMARKS
i.safe MOBILE and the i.safe MOBILE logo are registered trademarks of the
i.safe MOBILE GmbH. All other trademarks and copyrights are the properties of
their respective owners.
CONTACT/SERVICE CENTRE
FOR FURTHER QUESTIONS PLEASE CONTACT OUR SERVICE CENTRE:
i.safe MOBILE GmbH, i_Park Tauberfranken 10, 97922 Lauda-Koenigshofen, Germany
support@isafe-mobile.com
https://support.isafe-mobile.com
EU DECLARATION OF CONFORMITY
according to directives 2014/34/EU, 2014/30/EU, and 2011/65/EU
(2015/863/EU)
The company i.safe MOBILE GmbH declares under its sole responsibility that the
product to which this declaration relates is in accordance with the provisions
of the following data, directives and standards:
Name & address of the manufacturer in the EU| i.safe MOBILE GmbH
i_Park Tauberfranken 10 97922 Lauda — Koenigshofen Germany
---|---
Description of the devices| Explosion protected thermal camera
type / : IS-TC1A.1
model / : MTC1A01
Ex — marking| CAI 26 Ex ib IIC T4 Gb
CAI 2D Ex ib IIIC T135°C Db
Type examination certificate 2014/34/EU issued by
Applied harmonized standards| EPS 21 ATEX 1 197 X
Bureau Veritas E&E Product Services GmbH Businesspark A96
86842 Tuerkheim, Germany identification number / : 2004
EN IEC 60079-0:2018; EN 60079-11:2012
Conformity statement 2014/30/EU issued by
Applied harmonized standards| Shenzhen Morlab Communications Technology Co.,
Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, Shenzhen ,
GuangDong Province, P. R. China
EN IEC 61326-1:2021
Conformity statement 2015/863/EU amending 2011/65/EU issued by| Shenzhen
Morlab Communications Technology Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, Shenzhen,
GuangDong Province, P. R. China
Applied harmonized standards| IEC 62321-3-1: 2013; IEC 62321-5: 2013;
IEC 62321-4: 2013 + A1: 2017;
IEC 62321-7-1: 2015;
IEC 62321-7-2: 2017;
IEC 62321-6: 2015;
IEC 62321-8: 2017
---|---
CE Marking| 2004
**Lauda – Koenigshofen 09.02.2022
Dirk Amann
Managing Director
WWW.ISAFE-MOBILE.COM
**
References
- Zertifizierte Smartphones, Tablets und Mobiltelefone für IECEx und ATEX Zonen
- Wir beraten Sie weltweit
- Betriebsanleitungen, Produktflyer, Datenblätter uvm.
- Service & Support
- We advise you worldwide
- Datasheets, Manuals, Certificates and Product Folders
- Our service team will be happy to assist you
- I.SAFE MOBILE À L'ÉCHELLE MONDIALE
- Service chez
- Support - Official i.safe MOBILE Support
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>