i safe MOBILE IS-TH1xx.1 Barcode Scanner User Manual

June 5, 2024
i safe MOBILE

IS-TH1xx.1 Barcode Scanner
User Manual

PRODUCT DESCRIPTION

Document No. 1040MM01REV00
Version: 2021-04-06
(c) 2021 i.safe MOBILE GmbH
i.safe MOBILE GmbH
i_Park Tauberfranken 10
97922 Lauda-Koenigshofen
Germany
Tel. +49 9343/60148-0
[email protected]
www.isafe-mobile.com

INTRODUCTION

This document contains information and safety regulations that are to be observed without fail for the safe operation of the device IS-TH1xx.1 (Model MTHA10 / MTHA11) under the described conditions. Non-observance of this information and instructions can have serious consequences and/or may violate regulations.
Please read the manual and these safety instructions before using the device. In case of any doubt, the German version shall apply.
The current EU declaration of conformity, certificates, safety instructions, and manuals can be found at www.isafe-mobile.com or requested from i.safe MOBILE GmbH.

RESERVATION

The content of this document is presented as it currently exists. i.safe MOBILE GmbH does not provide any explicit or tacit guarantee for the accuracy or completeness of the content of this document, including, but not restricted to, the tacit guarantee of market suitability or fitness for a specific purpose unless applicable laws or court decisions make liability mandatory.
i.safe MOBILE
GmbH reserves the right to make changes to this document or to withdraw it any time without prior notice. Changes, errors, and misprints may not be used as a basis for any claim for damages. All rights reserved.
i.safe MOBILE GmbH cannot be held responsible for any data or other loss and direct or indirect damages caused by any improper use of this device.

EX-SPECIFICATIONS

The device IS-TH1xx.1 is suitable for use in potentially explosive atmospheres classified zone 1/21 and 2/22 in accordance with directives 2014/34/EU and 2014/53/EU, as well as the IECEx scheme.

ATEX:
II 2G Ex ib op is IIC T4 Gb
II 2D Ex ib op is IIIC T135°C Db
EU Type Examination Certificate:
EPS 20 ATEX 1 203 X
CE-designation: 2004| Temperature range:
-20°C … +60°C (EN/IEC 60079-0)
-10°C … +50°C (EN/IEC 62368-1)
---|---
IECEx:
Ex ib op is IIC T4 Gb
Ex ib op is IIIC T135°C Db
IECEx Certificate: IECEx EPS 20.0075X| Manufactured by:
i.safe MOBILE GmbH
i_Park Tauberfranken 10
97922 Lauda-Koenigshofen
Germany

EU-DECLARATION OF CONFORMITY

The EU declaration of conformity can be found at the end of this manual.

NAME CONCEPT

The two “xx” in IS-TH1xx.1 are placeholders. The IS-TH1xx.1 comes in two variants with different scan ranges and scan engines:

name (model) scan range scan engine
IS-TH1MR.1 (MTHA10) mid-range Zebra SE4750 (MR)
IS-TH1ER.1 (MTHA11) extended range Zebra SE4850 (ER)

FAULTS AND DAMAGES

If there is any reason to suspect that the safety of the device has been compromised, it must be withdrawn from use and removed from any ex-hazardous areas immediately.
Measures must be taken to prevent any accidental restarting of the device. The safety of the device may be compromised, if, for example:

  • Malfunctions occur.
  • The housing of the device shows damage.
  • The device has been subjected to excessive loads.
  • The device has been stored improperly.
  • Markings or labels on the device are illegible.

We recommend that a device displaying errors or in which an error is suspected be sent back to i.safe MOBILE GmbH to be checked.

EX-RELEVANT SAFETY REGULATIONS

Use of this device assumes that the operator observes the conventional safety regulations and has read and understood the manual, safety instructions, and certificate.
When used in ex-hazardous areas, the following safety regulations must also be complied with:

  • The device may be connected only outside ex-hazardous areas to the IS530.1 via the ISM interface.
  • To ensure the IP-protection, it has to be ensured that all gaskets are present and functional.
  • There must be no large gap between the halves of the housing.
  • The device must be securely fastened to the ISM interface when used in ex-hazardous areas.
  • The device may not be exposed to any aggressive acids or alkalis.
  • The device may only be used in zones 1/21 and 2/22.
  • Only accessories approved by i.safe MOBILE GmbH may be used.

FURTHER SAFETY ADVISES

CAUTION
Laser Light. Do not stare into beam class 2 laser product 630 – 680 nm, 1 mW.

  • Do not put the device in environments with excessive temperatures.
  • Do not use the device in areas where regulations or legislation prohibit its use.
  • Do not expose the device to strong magnetic fields, such as are emitted from induction ovens or microwaves.
  • Do not attempt to open or repair the device. Improper repair or opening can lead to the destruction of the device, fire or explosion. Only authorized personnel are allowed to repair the device.
  • Observe all corresponding laws that are in force in the respective countries regarding the use of devices while operating a vehicle.
  • Please power off the device before cleaning the device.
  • Do not use any chemical cleaning agents to clean the device. Use a damp and anti-static soft cloth for cleaning.
  • The user alone is responsible for any and all damages and liabilities caused by malware downloaded when using the network or other data-exchange functions of the device. i.safe
  • MOBILE GmbH cannot be held responsible for any of those claims.

WARNING
i.safe MOBILE GmbH will not assume any liability for damages caused by disregarding any of these advices or by any inappropriate use of the device.

MAINTENANCE/REPAIR

Please note any legal requirements for periodic inspection.
The device itself has no user-serviceable parts. It is recommended to perform inspections according to the safety regulations and advice. If there is a problem with the device, please contact your vendor or consult the service center. If your device is in need of repair, you can either contact the service center or your vendor.

PRODUCT DESCRIPTION (see illustration on page 2)

  1. HOLDER: Holder for IS530.1
  2. PLUG: Connecting IS530.1
  3. SCAN BUTTON: Scanning barcodes.
  4. EYELET: Eyelet for the hand strap.

INSTALLATION

WARNING
The device may be connected only outside ex-hazardous areas to the IS530.1 via the ISM interface!

  • Unscrew the cover of the ISM interface (1) located on the IS530.1.
  • Push the IS530.1 completely into the holder (2) of the device.
  • Unscrew the screw (3).
  • Loosen the plug (4).
  • Attach the plug on top of the ISM interface (5).
  • Fix the plug by pressing the rounded end of the plug (6).
  • Tighten the screw (7).
  • Check whether the plug is correctly and firmly attached to the ISM interface.

The device can now be used together with the IS530.1 inside ex-hazardous areas.

RECYCLING

The crossed-out wheeled bin symbol on your product, battery, literature, or packaging reminds you that all electrical and electronic products, batteries, and accumulators must be taken to separate collections at the end of their working life. This requirement applies to the European Union. Do not dispose of these products as unsorted municipal waste. Always return your used electronic products,  batteries, and packaging materials to dedicated collection points. This way you help prevent uncontrolled waste disposal and promote the recycling of materials. More detailed information is available from the product retailer, local waste authorities, national producer responsibility organizations, or your local i.safe MOBILE GmbH representative.
Correct Disposal of this product. This marking indicates that this product should not be disposed other household wastes throughout the EU.
To prevent possible harm to the environment or humans from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources.
To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmentally safe recycling.

TRADEMARKS

  • i.safe MOBILE and the i.safe MOBILE logo are registered trademarks of the i.safe MOBILE GmbH.

CONTACT/SERVICE CENTER

FOR FURTHER QUESTIONS PLEASE CONTACT OUR SERVICE CENTER:
i.safe MOBILE GmbH, i_Park Tauberfranken 10, 97922 Lauda-Koenigshofen, Germany
[email protected]
www.isafe-mobile.com/service

EU – Declaration of Conformity
according to directives 2014/34/EU, 2014/30/EU, 2014/35/EU, and 2011/65/EU (2015/863/EU)
The company i.safe MOBILE GmbH declares under its sole responsibility that the product to which this declaration relates is in accordance with the provisions of the following data, directives and standards:

Name & address of the manufacturer in the EU| i.safe MOBILE GmbH
i _Park Tauberfranken 10
97922 Lauda — Koenigshofen, Germany
---|---
Description of the devices| Trigger Handle
type / IS-TH1MR.1 and IS-TH1ER.1
model / MTHA10 and MTHAll
Ex — marking| 112G Ex ib op is IIC T4 Gb
II 2D Ex ib op is IIIC T135°C Db
Type examination certificate 2014/34/EU issued by
Applied harmonized standards| EPS 20 ATEX 1 203 X
Bureau Veritas E&E Product Services GmbH Businesspark A96
86842 Tuerkheim, Germany
identification number / 2004
EN 60079-0:2018; EN 60079-11:2012; EN 60079-28:2015
Conformity statement 2014/30/EU, 2014/35/EU, and 2015/863/EU amending 2011/65/EU issued by Applied harmonized standards| Shenzhen TCT Testing Technology Co., Ltd. 1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Baoan District, Shenzhen, Guangdong, China
EN 55032:2015; EN 55035:2017; EN 62368-1:2014+A11:2017; IEC 62321-2:2013;
IEC 62321-3-1:2013; IEC 62321-5:2013; IEC 62321-4:2013 + AMD1 2017;
IEC 62321-7-1:2015; IEC 62321-7-2:2017;
IEC 62321-6:2015; IEC 62321-8:2017; EN 60825-1:2014; EN62471:2008

EU-DECLARATION OF CONFORMITY

CE Marking 2004

Lauda- Koenigshofen 07.04.2021 Dirk Amann
Managing Director

WWW.ISAFE-MOBILE.COM

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

i safe MOBILE User Manuals

Related Manuals