EBECO EB500 Electric Floor Heating Thermostat Instruction Manual
- June 6, 2024
- EBECO
Table of Contents
EB-Therm 500
MANUAL
EB500 Electric Floor Heating Thermostat
Important!
The underfloor heating system is a main voltage installation and must
therefore be installed by an authorised electrician in accordance with the
current national regulations.
This is EB-Therm 500
EB-Therm 500 is a thermostat that is equipped with a 1.8″ TFT colour
display and capacitive touch screen for easy and clear navigation.
The EB-Therm 500 has several energy saving programmes with individually
adjustable times and temperatures. The adaptive function means that the
thermostat collects data from the time it is started up and uses this to
calculate when to turn on. A PI controller keeps temperature fluctuations to a
minimum, which gives an even heat.
The EB-Therm includes a ventilation function that turns the heat off for 15
minutes if it detects that the temperature drops by more than three degrees in
less than one minute.
EB-Therm 500 is wifi-ready. By purchasing the EB-Connect WiFi accessory, you
can easily control the heat with our Ebeco Connect app or the open API. The
WiFi module is available at your nearest retailer. The app can be downloaded
from Google Play and App Store.
Included in the package
- Front for ELKO Plus/RS
- Front for Schneider Exxact
- Frame
- Thermostat
- Foor sensor
- Connection clamp Manual
Fitting the EB-Therm 500
EB-Therm 500 should not be placed so it is exposed to direct sunlight and
draughts because these can affect the thermostat functions. Take into account
the thermostat IP class when fitting.
The floor sensor is fitted in a spiral tube placed at the height of the floor
surface.
The end of the hose must be sealed in order to simplify replacement of the
floor sensor.
Fit the EB-Therm in a 65 mm junction box. Ensure the box is flush with the
wall or alternatively the tiles.
- Lift the front panel and frame by pushing a screwdriver into the groove on the underside, see picture. Lift the front panel upwards until you hear a “click”.
- Connect according to the instructions on the back of the thermostat. The protective conductor for incoming supply and heating cable is connected using a connection clamp in the box.
- Fit the thermostat in the box, with the arrow pointing upwards. Insert the thermostat in the junction box and fasten with existing screws.
- Replace the front panel by first hooking it into the lower part, see picture. Then push in the upper part of the front with your thumb until you hear a “click”.
Changing the front cover
- Lift the front panel and frame by pushing a screwdriver into the groove on the underside, see picture. Lift the front panel upwards until you hear a “click”.
- Use a screwdriver to gently loosen the front panel.
- Fit a new front and push until you hear a “click”.
Getting started
The EB-Therm 500 has a built-in start-up guide that takes you through each
step in a simple way. When energizing the thermostat for the first time, the
system will guide you through the most common and important settings that are
required. You should wait four weeks after applying filler before the floor
heating is turned on.
This gives the filler time to dry properly.
The thermostat will automatically count down and turn on the floor heating
when four weeks have passed.
If you have any questions regarding the usage of EB-Therm 500, please contact
us at Ebeco at any time. Call +46 31 707 75 50 or send an e-mail to
info@ebeco.se.
The touch surfaces
The EB-Therm 500 has a number of touchsurfaces on the front of the thermostat.
These surfaces are illuminated and are outside the screen itself.
- On/off/to home screen
- Scroll up/to the right
- Menu/confirm
- Scroll down/to the left
- Go back one step
The menus
The thermostat’s menus and features are listed below, along with explanations.
Main menu: Program
Not selected| If no program is selected, the ther- mostat provides constant
heat.| Preset to 22 °C. Adjustable 5–35 °C.
---|---|---
Week| Preset times and temperatures.
Individually adjust-able.| Mon–Fri
Wake up 06:00,
22 °C
Leave 08:00, 17 °C
Return 15:00, 22 °C
Sleep 23:00, 17 °C.
Sat–Sun
Wake up 07:00, 22 °C
Sleep 23:00, 17 °C
Office| Preset times and temperatures.
Individually adjust- able.| Mon–Fri 08:00, 22 °C
17:00, 17 °C
Timer| Active
Standby (can be deactivated)
Operating time| Preset to 22 °C. Adjustable 5–35 °C.
Preset to 17 °C Adjustable (Off) 5–35 °C
Preset to 4 h Adjustable 0–99 h
Remote control (requires remote control on, see menu for install- ers on page
29)| Active
Standby (can be deactivated)
After-heating| Preset to 22 °C. Adjustable 20–35 °C.
Preset to 17 °C. Adjustable (Off) 5–35 °C.
Preset to 0 h Adjustable 0–12 h
Resetting| Software reset|
Main menu: Energy consumption
Week
Time & kWh
| | Shows the week, kWh and number of hours.
---|---|---
Month Time & kWh| | Shows the month, kWh and number of hours.
Year
Time & kWh| | Shows the year, kWh and number of hours.
Operation (14 days)| Displayed as a bar graph.| The bars indicate the
operating period per day.
Main menu: Settings
WiFi| Select net- work.
WPS
Reset account| Displays the selected network and connection status.
Wireless Protected Setup
Restoring connection to app.
---|---|---
Time & date| Set the time and date| WiFi: set the time zone.
Language| Set the desired lan- guage.| Swedish English Norwegian Finnish
German
Screen saver| Screen saver with three dif- ferent styles.| Preset Time & temp.
Adjustable Time & date No (off)
Keypad lock| On/Off| Preset to Off
Summer time| On/Off| Preset to On
Adjusts clock automati- cally for summer time.
Main menu: Installer
System info | Displays the settings and calibrations. |
---|---|
Applications | Hotel |
Preset to 25 °C
Adjustable 20–27 °C
Standby
Preset to 15 °C
Adjustable (Off) 5–20 °C
After-heating
Preset to 2 h
Adjustable 0–4 h
Interval
Min. Preset to 22 °C
Adjustable 20–23 °C
Max. Preset to 27 °C
Adjustable 22–30 °C
Automatic lock function
Activated remote control
access locks the thermostat.
Screen saver Temp. & time
Remote control| On/Off
If the remote control is turned on Remote control is displayed below the menu
“Programme”. Requires a 230 V signal on remote access (see
page 23).
Comfort heating (low output heat)| On/Off
Preset to 25/20 °C
Adjustable 5–27 °C
See program “Residence” for periods and other temperatures.
Power control| Displayed as a %
Pause/running time 20 min (in cycles).
The current temperature is shown in the display.
Ground heating| On/Off
Preset to 8 °C/Off
See program “Timer”. The current outdoor temperature is shown in the display.
Sensors| Sensor selection| Floor sensor| Tile/stone
Room sensor| Tile/stone
Room sensor + limited floor
Max. (overheating)
Preset to 30 °C
Adjustable 27–35 °C
Min. (comfort)
Preset to 5 °C
Adjustable (Off )
5–25 °C| Wood/laminate/
vinyl
Floor sensor + limit.
room
Max (room restriction)
Preset to 25 °C
Adjustable 20–27 °C| Tile/stone wood/laminate/ vinyl
Sensor type| NTC 2 kΩ
NTC 10 kΩ
NTC 12 kΩ
NTC 15 kΩ
NTC 22 kΩ
NTC 33 kΩ
NTC 47 kΩ
NTC 100 kΩ| As a guide, the current temperature
for each sensor type is displayed.
Calibra-tion| Floor sensor
Room sensor| If required the respective sensors can be
calibrated.
Important!
In rooms exposed to solar radiation (large windows), we recommend the function
“room and floor thermostat”.
In rooms with wooden floors the function “room and floor thermostat” must
always be used.
Main menu: Installer (continued)
Installed effect| Preset to 500 W.
Adjustable.| Required to display energy consumption.
---|---|---
Features| Adaptive function| On/Off (preset On) Read more on page 20.
Ventilation function| On/Off (preset On) Read more on page 20.
Delayed start Operating time limitation| Should heating be started in 4 weeks
time? OK/No
Operating
time limitation| The underfloor heating is turned off for x minutes per hour.
Preset to Off Adjustable 1–15 min
Reset| Reset all|
Save data| Saving energy consumption. Other settings will be reset.
Operating information
The thermostat display shows the operating information under the setpoint.
Operating information
Right now| Display of the current temp and sensors.|
---|---|---
After X: XX (time in hours
until setpoint is reached)| Set| Set point reached.
Limited| Maximum or minimum limitation is activated. The function is activated
under Sensor selection. Read more on page 30.
Ventilation| The ventilation function turns the heat off for 15 minutes if it
detects that the temperature drops by more than three degrees in less than one
minute.
Troubleshooting
When a fault occurs, the EB-Therm 500 turns the heating off. The display then
shows an error code.
E1 Short circuit room sensor.
E2 Interruption room sensor.
E3 Short circuit floor sensor.
E4 Interruption floor sensor.
E5 Internal sensor fault.
E6 Internal over temperature
Please note that the floor heating system is a high voltage system and any
faults must therefore be rectified by an authorised electrician.
Test values for floor sensors
For control measurement of the floor sensor, the following values for Ebeco
standard sensor NTC 10 kΩ apply.
Temperature | Resistance |
---|---|
10 °C | 18.0 kΩ |
15 °C | 14.7 kΩ |
20°C | 12.1 kΩ |
25 °C | 10.0 kΩ |
30°C | 8.3 kΩ |
Connection voltage | 230 VAC ±10% 50–60 Hz |
--- | --- |
Air temp. range | +5 °C to +35 °C |
Floor temp. range | +5 °C to +35 °C |
Temp. limiter | +5 °C to +35 °C |
Breaking capacity | 3680 W/16 A/230 VAC |
Connection cable | max 2.5 mm² |
Load | Cos φ = 1 |
Conn. difference | ± 0.3 °C |
Power reserve | 36 h |
Sensor cable | 3 m, NTC 10 kΩ |
Maximum length | 50 m, 2 x 1.5 mm² |
sensor cable | 36 x 29 mm |
Display dim. | 87 x 87 x 39 mm |
Thermostat dim | Schneider Exxact, |
For frame system | ELKO Plus/RS |
Colour | White |
Enclosure class | IP21 |
Approval | CE, S |
Protection class | Class II, reinforced insulation (EN 60730) |
Thank you for choosing Ebeco. Good luck with the use of your EB-Therm 500 and
floor heating unit. We hope you will enjoy it for a long time to come.
For the guarantee to apply, the product must be installed and used as
described in this manual. It is therefore important that you read the manual.
This applies both to those who install the EB-Therm 500 and those who use it.
You’ll also find troubleshooting information and technical data.
Warranty
Ebeco AB provides a 5-year product warranty for material defects for the
EBTherm 500. For more detailed warranty terms, see
ebeco.com.
EBECO AB
Lärjeågatan 11
415 02 Göteborg SWEDEN
+46 31 707 75 50
info@ebeco.se
ebeco.se
Manual EB500 240305
Read User Manual Online (PDF format)