EBECO Cableflex 11 Cable Kit Installation Guide

June 1, 2024
EBECO

EBECO Cableflex 11 Cable Kit

EBECO-Cableflex-11-Cable-Kit-product-image

Specifications

  • Cable Kit 500: 100 W, 8.9 m
  • Cable Kit 200: 150 W, 13.5 m
  • Cableflex 11:

Product Information

The Cable Kit 200/500 Cableflex 11 is designed for electric local space heating and complies with eco design regulations. It offers various heat output options and temperature control features.

Product Usage Instructions

Installation

  1. Ensure the surface is suitable for installation (concrete surface recommended).
  2. Lay out the Cable Kit according to the desired heat output.
  3. Use the provided Cable Clips, Cable Boards, Tape, Sensor Tube, and Adhesive Sticks for installation.
  4. Prime the surface if necessary before installation.
  5. Place the sensor and connection cables appropriately.

Control Options

  • Room temperature control with or without electronic features
  • Adaptive start control
  • Open window detection
  • Distance control detection

Maintenance

  • Regularly check the system for any damages or malfunctions.
  • Clean the surface and cables as needed to ensure optimal performance.

FAQ

  • Q: Can I install the Cable Kit on any type of flooring?
    A: It is recommended to install the Cable Kit on concrete surfaces for best results.

  • Q: What are the different control options available with the Cable Kit?
    A: The Cable Kit offers room temperature control with various features such as electronic control, adaptive start control, open window detection, and distance control detection.

Cable Kit 200/500
Cableflex 11

INSTALLATION INSTRUCTIONS

garantera.ebeco.se

Ecodesign

Information requirements for electric room heaters
In accordance with the ecodesign requirements for room heaters according to Regulation EU 2015/1188EBECO-Cableflex-11-Cable-Kit-fig-
\(2\) EBECO-Cableflex-11-Cable-Kit-fig-
\(3\)

EBECO AB
Lärjeågatan 11
SE-415 02 Gothenburg, SWEDEN
Phone +46 31 707 75 50
ebeco.com
info@ebeco.se

Welcome!
Thank you for choosing Ebeco. We hope you will be happy with your underfloor heating system for many years to come. For the guarantee to apply, the product must be installed and used as described in this manual. It is therefore important that you read the manual.

If you have any questions, please contact us at Ebeco. Call 031-707 75 50 or send an email to info@ebeco.se . You’ll find more information at ebeco.se.

Important

The underfloor heating system is a high voltage system and must thus be installed according to applicable regulations by an authorised electrician. For the guarantee to apply, the guarantee certificate must be correctly and completely filled in, and signed by an authorised electrician.
May only be installed indoors.

  • The heating cable must not be cut. Furthermore, it may neither be crossed nor installed with spacing of less than 5 cm.
  • The connection cable may be cut.
  • The thermostat’s sensor cable may be cut.
  • The cable must be measured for resistance and insulation as per the instructions. Document the values in our web app, Garantera Ebeco, or in the guarantee certificate.
  • Either a diagram or photo of the cable routing must be documented.
  • The sign Heating Cable Installed must be posted at the main junction box.
  • Heating must be regulated with Ebeco’s EB-Therm thermostats.
  • The system must be connected to 230 V via a 30-mA earth fault circuit breaker.
  • The heating cable must not be run under stationary furnishings, such as kitchen counters, closets, inner walls, etc. because this produces elevated temperatures.
  • In wet rooms, the heating cable must be run under a sealing layer.
  • Wait 4 weeks after applying screed before turning on the heat. This gives the screed time to dry properly.
  • In rooms with wooden floors the Room and floor thermostat function must always be used.
  • When laying on reinforcement mesh, the cable must be laid on the top of the reinforcement mesh.
  • The maximum permissible heat resistance of the floor material is 0.16 m² K/W.

Subflooring

  • The heating cable is laid on floor constructions of concrete, plaster or chipboard and must then be screened with a suitable levelling compound.
  • When applying screed on EPS concrete/cement, a reinforcement mesh is required in between as a spacer before the heating cable is laid.
  • On uninsulated concrete floors against the ground, additional insulation is always recommended. Also, that the heating is not switched off completely during the summer to counteract moisture rising.

Flooring materials

  • Cable Kit/Cableflex can be installed under tiles and natural stone floors, wood and laminate floors and linoleum.
  • When screeding, the heating cable must be laid in a minimum screed layer with a suitable levelling compound as follows:
    • Tile/natural stone floor 5 mm
    • Wood/laminate flooring, 10 mm
    • Linoleum 15 mm
  • See the applicable industry regulations for exact instructions regarding floor construction, screeding, sealing layers, tiling, jointing etc. Please contact your dealer for answers to specific questions.

Recommendations and Max. output depending on criteria and needs:

EBECO-Cableflex-11-Cable-Kit-fig-24 The output requirement of the room is governed by how well insulated it is, its air circulation and outdoor temperature.

  • Industry guidelines for wood/laminate and linoleum on underfloor heating

  • General conditions: The maximum permissible surface temperature is 27°C. This also applies under carpets and furniture.

  • Coverage:
    Note that with all covering of wood/laminate and linoleum floors laid on underfloor heating, there is a risk:

    • Of overtemperature in the floor
    • That the temperature in the room becomes too low
  • Coverings include: carpets, beds without ventilated bases, bookshelves with fully-covering bottom, kitchen cabinets etc.

Specifications

Only on concrete subflooring

EBECO-Cableflex-11-Cable-Kit-fig- \(5\)

Materials and accessories

EBECO-Cableflex-11-Cable-Kit-fig- \(6\)

Accessories

  • Cable Clip (89 609 58)
  • Cable Board (89 601 80)
  • Tape (89 353 49)
  • Sensor hose (89 605 41)
  • Adhesive sticks (16 939 93)

Compare with the contents in your kit. Check the label on the cable reel to ensure that you have received the correct cable length.

Plan the installation

Because the heating cable may neither be cut nor crossed, installation must be carefully planned so that the cable is correct for the room. Use the metre marking on the cable after half the installation to make any adjustments to c/c distances and to avoid surplus heating cable once the calculated area has been covered.

Calculate the c/c distance
Do as follows to find the exact c/c distance for cable laying. Calculate the room’s floor area. Subtract for fixed furnishings, such as cabinets and counters, so that you obtain the free floor area. Divide the free floor area by the cable length to obtain the c/c distance. Depending on the c/c distance, output varies per square metre. In the table, Specifications, you can see the output for various c/c distances.

Location of sensor and connection cables

  1. Cable Kit includes a spiral tube with sealed ends.
    The thermostat’s sensor cable is inserted in the spiral tube.

  2. The sensor cable’s termination may not be covered by carpets or furnishings.

  3. The underfloor heating cable has a 2.5-metre connection cable. It is run in a VP tube/plastic tube designed for electrical materials (not included).

  4. The joint for the connection cable and termination may not be placed in or adjoining any shower spaces/floor drains. For supplementary kits, both cold cables must be run up and connected in parallel in the thermo-stat.

  5. The spiral tube and the pipe are placed next to each other in a recess in the wall.
    If necessary, a recess for the spiral tube is made in the floor between two heating cables, ending 30 – 60 cm from the wall. The joint between the heating and connecting cable should be embedded and must not be laid in the wall or in a conduit, nor should it be bent. The nearest bend must be at least 10 cm from the joint (see picture).

Installation

  1. The reel bracket simplifies work. Place the reel bracket in the perforated hole under the bottom of the package. Lift the reel onto the reel bracket and place a weight on the package cover. When you pull the cable, the reel will now revolve.
  2. Perform the first insulation and resistance measurement of the cable. Fill in the test report or use Garantera on your smartphone.EBECO-Cableflex-11-Cable-Kit-fig- \(13\)

Prepare the subfloor

  1. Ensure that the floor is firmly in place, does not sag and is free from dirt and old floor coverings. Prime the floor surface with Ebeco Primer + (89 605 50) or similar and let it dry.
  2. Mark the c/c dimensions of the heating cable. Distance to the wall must be the loop’s c/c dimensions divided by two.EBECO-Cableflex-11-Cable-Kit-fig- \(14\)
    The heating cable can be attached with either hot melt adhesive, tape (89 353
  1. or Cable Clip (89 609 58) for mesh 2.5 mm. Adhesive is used in the figures. Follow the instructions in general.
    Adhesive is preferable for uneven surfaces. Secure the cable with drops of adhesive instead of complete bonding. The lowest application temperature for tape is +18°C, otherwise adhesion is reduced.
    In rooms where the underfloor heating cables are to be installed on 2.5 mm mesh, Cable Clip is the ideal accessory. Cable Clip is easily attached to the mesh. The heating cable is then installed directly in the clip.
  1. Pull out the first length of heating cable and secure it. The distance to the wall must be the c/c dimensions of the loop divided by two.

  2. This is how the heating cable should be laid around floor drains and similar. Leave space for the floor drain grille. NB! At least 20 cm distance between drain and heating cable! The cable may not be installed under fixed furnishings, such as toilet bowls. It can be advantageous to secure toilet bowls with silicone instead of screws.

  3. Fastening of heating cable must be done with c/c 20 cm.

  4. Perform other insulation and resistance measurements and fill in the test report or Garantera on your smartphone. Document the location of the cable with a photo.

  5. Cover the floor with a suitable floor filler. Keep in mind that the cable must be under the sealing layer in wet rooms.

  6. If possible, after applying screed, alternatively after flooring has been laid, perform a third insulation and resistance measurement of the heating cable. Fill in the test report or use Garantera on your smartphone.

For tiles, wait 4 weeks after installation before turning on the heat.

Energy-saving tips!
Ebeco Cable Board is an insulation board especially designed for Cable Kit/Cableflex under tiled and natural stone floors. It has grooves for laying the heating cable and consequently provides quick and uniform positioning of the heating cable without the need of manually measuring centre-to-centre distances. The insulation board’s properties make the underfloor heating system extremely responsive to adjustments. Compared to the reference installation (60s-70s house with an uninsulated floor construction of 15 cm thick concrete slab on the ground), Cable Board provides an energy saving of up to 45%. On concrete surfaces, it can be used both in wet rooms and dry areas. On wooden surfaces, it may only be used in dry areas and then replaces the plasterboard in the floor construction. In wet rooms with wooden subfloors, Ebeco Thermo Board is recommended.

Test report (Cable Kit 200/500, Cableflex 11)

| Before laying| After fixation| After floor covering
---|---|---|---
Product| Resistance value| Insulation value| Resistance value| Insulation value| Resistance value*| Insulation value
E-no.: ……………….| | | | | |
E-no.: ……………….| | | | | |
E-no.: ……………….| | | | | |
E-no.: ……………….| | | | | |

Min. insulation value 10 MΩ at min. 500 V test voltage.
*Tolerance -5 % – +10 %

Products

EBECO-Cableflex-11-Cable-Kit-fig- \(22\)

Is installed in the following spaces:EBECO-Cableflex-11-Cable-Kit-fig-
\(23\)

  • Extended 25 year guarantee and documenting made easier with Garantera
  • Do you want to avoid the bother of filling in and keeping track of these pages? Garantera is a service that makes things a little easier for authorised installation technicians. The service allows you to document measurement data, save installation photos and create a digital guarantee certificate to send to the customer. Read more about the service and get started at garantera.eboco.se.

The installation is documented with photos/drawings

  • Electrical installation performed by:
    • Company: ………………………………………………………..
    • Date: …………………………………………………………. . . . ..
    • Installer (block capitals): ………………………………… ……
    • Signature: ………………………………………………………..

Terms of Guarantee

Cable Kit, Cableflex, Thermoflex Kit, Thermoflex, Foil Kit, Foil 230 V and Multiflex 20

  • Ebeco AB provides a 12-year guarantee for material faults to heating cables/foil including supplied accessories and insulation board in Cable Kit, Thermoflex Kit, Thermoflex, Foil Kit, Foil 230 V and Multiflex 20-cable, hereafter referred to as the “Products”.

  • Should material faults occur to the Products during the period of the guarantee, Ebeco AB agrees to repair or replace the Products without cost to the purchaser. Ebeco AB also undertakes to restore the floor to its original condition after performed repair or replacement. To be able to rectify the fault, the purchaser must have saved or have access to 1 m² of the original flooring material.

  • Ebeco AB provides a 5-year product guarantee for the supplied thermostat.

  • The guarantee only applies under the condition that installation of the Products is performed by an authorised electrician in accordance with applicable regulations and the installation instructions issued by Ebeco. And that one of the following requirements is met:

    • The installation is performed using and documented in Ebeco’s service, Garantera.
      Or

    • This guarantee certificate including the test report is completed in full, and along with material specifications or an invoice, signed by the electrician who performed the installation. Furthermore, there must be photos that show the Products in their entirety after installation but before covering, or alternatively, a detailed drawing of the end connections and joints of the Products as well as the exact locations of floor sensors.

  • The guarantee does not apply to installations performed by non-authorised electricians or if a non-authorised electrician has made modifications or repairs. Furthermore, the guarantee does not apply to faults that have occurred as a result of use of improper materials and floor constructions, or as a result of incorrect installation. Damage caused by vandalism, fire, lightning or water, or damage caused by carelessness, abnormal use or as a result of accidents, is not covered either.

  • To make a guarantee claim, the following applies: Ebeco AB must be notified before any action is taken. Furthermore,
    a guarantee certificate with an accompanying invoice for installation or material specification and a completed and signed test report must be presented.

Extend the guarantee to 25 years with Garantera

  • Ebeco’s digital service, Garantera, documents all heating cable installations in a simple, safe and structured way. An installation made using Garantera automatically gets an extended 25 year guarantee for material defects. The extended guarantee only applies if the product has been installed together with an applicable control system and by an authorised electrician.
  • A digital guarantee certificate is e-mailed from Garantera to the user, who is then responsible for saving it and being able to present it in the event of a guarantee claim.
  • A product guarantee of 5 years applies to the thermostat.
  • EBECO AB
  • Martin Larsson, CEO

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals