EBECO F-10 Splice Kit Instruction Manual

June 12, 2024
EBECO

EBECO F-10 Splice Kit

Product Information

The product is a splice kit, specifically designed for use with F-10, T-18, and T-18 CT cables. It is used for joining cables together and ensuring proper insulation and connection.

Product Usage Instructions

  1. Slide both shrink tubings provided onto the cables. Use 1 piece of 12 mm shrink tubing with a length of 180 mm and 1 piece of 9 mm shrink tubing with a length of 110 mm.
  2. Strip off 60 mm of the outer sheath of the cable, and cut away the earth, leaving a maximum of 10 mm.
  3. Twist the earth wire and secure it in place with an uninsulated terminal.
  4. Strip away 30 mm of the inner insulation from the cable.
  5. Make 2 cuts in the semi-conductor material leading to the conductors.
  6. Pull the conductors apart or cut between them.
  7. Slide on both 3 mm shrink tubings and then the 9 mm shrink tubing, following the illustration provided. The 9 mm shrink tubing should be 15 mm long.
  8. Heat the shrink tubings with a hot air gun, and then squeeze them together between the conductors using a flat plier.
  9. Strip 6 mm off the conductors.
  10. Repeat steps 2 to 9 with the other cable.
  11. Splice the cables together using the insulated shrink-tubing terminals. Heat the splice with a hot air gun so that the shrink tubings shrink and the adhesive is pressed out.
  12. Pull 9 mm of shrink tubing over the splice and heat it. Use a piece of 9 mm shrink tubing with a length of 110 mm.
  13. Insulation test the cable, ensuring a minimum of 10 M resistance.
  14. Always heat the shrink tubings until the adhesive is pressed out. Do not lay a spliced cable inside a water pipe.
  15. Wrap electrical tape over the splice to make it even.
  16. Pull 12 mm of shrink tubing over the splice and heat it. Use a piece of 12 mm shrink tubing with a length of 180 mm.

For further assistance or inquiries, you can contact Ebeco at:

Package Contents

  • 1 pc 12 mm shrink tubing, L=180 mm
  • 1 pc 9 mm shrink tubing, L=110 mm
  • 2 pc 9 mm shrink tubings, L= 15 mm
  • 4 pc 3 mm shrink tubings, L= 25 mm
  • 2 pc insulated crimp terminals 1,5 mm²
  • 2 pc uninsulated terminals 1,5 mm²

Mounting Instructions

  1. Slide both shrink tubings on the cables.
    • 1 pc 12 mm L = 180 mm
    • 1 pc 9 mm L = 110 mm
  2. Strip off 60 mm of the outer sheath, and cut away the earth leaving a maximum of 10 mm.
  3. Twist the earth, and squeeze in place an uninsulated terminal.
  4. Strip away 30 mm of the inner insulation
  5. Make 2 cuts in the semi-con-ductor material leading to the conductors.
  6. Pull the conductors apart or cut between the conductors.
  7. Slide on both 3 mm shrink tubings and then the a 9 mm skrink tubing, 15 mm long according to the illustration.
  8. Heat with a hot air gun, and then squeeze together between the conductors with a flat pliers.
  9. Strip 6 mm off the conductors.
  10. Repeat the step 2 to 9 with the other cable.
  11. Splice the cables together with the insulated shrink tubing terminals. Heat with a hot air gun so that the shrink tubings shrink and the adhesive is pressed out.
  12. Pull 9 mm of shrink tubing over the splice, and heat.
    • 1 pc 9 mm L = 110 mm
  13. Splice the earth together with a 1.5 mm² piece of insulating cable.
  14. Wrap electrical tape over the splice to make it even.
  15. Pull 12 mm of shrink tubing over the splice, and heat.
    • 1 pc 12 mm L = 180 mm
  16. Insulation tests the cable, min 10 MΩ.
    Always heat the shrink tubings until the adhesive is pressed out. Do not lay a spliced cable inside a water pipe.

EBECO Heating solutions

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

EBECO User Manuals