Congratulations on purchasing this device. Please read the following instructions carefully and follow them to prevent possible damages. We assume no liability for damage caused by disregard of the instructions and improper use. Scan the QR code to get access to the latest user manual and more product information.

TECHNICAL DATA

Item number| 10028655, 10030099, 10030212,

10030213

---|---
Power supply| 220-240 V ~ 50/60 Hz
Note : You can purchase an activated carbon filter separately for this cooker hood under item number 10029644. Please visit our website: www.hifi- tower.co.uk

SAFETY INSTRUCTIONS

  • Thank you for purchasing this cooker hood. Please read the instruction manual carefully before you use the cooker hood, and keep it in a safe place.
  • The installation work must be carried out by a qualified electrician or competent person. Before you use the cooker hood, make sure that the voltage (V) and the frequency (Hz) indicated on the cooker hood are exactly the same as the voltage and the frequency in your home.
  • The manufacturer and the agent will not bear any responsibility for the damage caused by inappropriate installation and usage.
  • Children under the age of 8 must not use the cooker hood.
  • The appliance is not intended for commercial use, but only for household and similar environments.
  • The cooker hood and its filter mesh should be cleaned regularly in order to keep it in good working order.
  • Before cleaning, switch the power off at the main supply.
  • Clean the cooker hood according to the instruction manual and keep the cooker hood from the danger of burning.
  • Prohibit putting the cooker hood by fire.
  • If the appliance does not function normally, contact the manufacturer or a specialist company.
  • This device may be only used by children 8 years old or older and persons with limited physical, sensory and mental capabilities and / or lack of experience and knowledge, provided that they have been instructed in use of the device by a responsible person who understands the associated risks.
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • If the range hood is used at the same time as appliances burning gas or other fuels, the room must be adequately ventilated.
  • Do not flambé under the range hood. Accessible parts may become hot when used with cooking appliances.

Important hints on installation

  • The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels (not applicable to appliances that only discharge the air back into the room).
  • Regulations concerning the discharge of air have to be fulfilled.

Important notes about the extraction mode
WARNING
Risk of poisoning from exhaust gases sucked back. Never operate the device in extraction mode simultaneously with an open fl ue appliance when there is not adequate airfl ow guaranteed.

Open fl ue combustion equipment (for example, gas, oil, wood or coal-fi red heaters, tankless water heaters, water heaters) pulls combustion air from the room and runs it through an exhaust pipe or chimney to the outside. In the extraction mode, indoor air is removed from the kitchen and the adjacent rooms – without suffi cient air intake this creates a vacuum. Toxic gases from the chimney or extraction fl ue can thereby be sucked back into the living spaces.

  • Always ensure that a suffi cient supply of fresh air is guaranteed and that the air can circulate.
  • An air supply / extractor box alone does not ensure compliance with the limit value.

Safe operation is only possible when the negative pressure in the room where the appliance is located does not exceed 4 Pa (0.04 mbar). This can be achieved when the air required for combustion can fl ow through openings that are not closable, for example in doors, windows, in conjunction with an air supply / extractor box or through other technical measures. In any case, consult a qualifi ed chimney sweep who can assess the entire ventilation of your house and propose appropriate measures for adequate ventilation. If the hood is used exclusively in the recirculation mode, unrestricted operation is possible.

Important note on disassembly of the device

  • Disassembly is similar to installation/assembly in reverse order.

  • Take a second person to help you during disassembly to avoid injuries.

MOUNTING

  1. The distance between the cooking surface and the lowest edge of the cooker hood must be at least 65 cm.
  2. Once the height is defined, install the anchoring in the appropriate place. To do this, you must first drill holes, and then fasten the anchorage to the wall with the screws. (You will need a drill, suitable drill bits, dowels and screws).
  3. After the anchoring is fixed, according to the similar procedure, attach the inside bracket for the fireplace facing. Make sure that the distance is correct (please measure the distance), because the fireplace facing will be fixed to the bracket later.
  4. Fix the outside clamp for the chimney facing to the outside of the facing and check that the inside chimney facing can move freely in height. 5.
  5. Place the hood on the anchors (fasteners).
  6. Set the correct height of the inner chimney facing so that the brackets match and fix them. Then you can fix the hood with the safety screws.

KLARSTEIN-10028655-Lorea-60cm-Range-Hood-1

OPERATION

Before operating the device for the first time after proper installation, please connect the hood to the mains (please observe the generally valid safety instructions).

Control panel keys

KLARSTEIN-10028655-Lorea-60cm-Range-Hood-2

TROUBLESHOOTING

Fehler Mögliche Ursache Lösung
Light on, but motor does not work. The leaf blocked. Get rid of the

blocking.
The capacitor damaged.| Replace capacitor.
The motor jammed bearing

damaged.

| Replace motor.
The internal with of motor off or a bad smell from the motor.| Replace motor.
Light does not work, motor does not work.| Light damaged.| Replace lights.
Power cord looses.| Connect the wires as per the electric diagram.
Insufficient

suction.

| The distance between the body and the gas top too long.| Readjust the distance.
Too much ventilation from

open doors or windows.

| Choose a new place and resemble the machine.

PRODUCT DATA SHEET

Information according to Regulation (EU) No. 65/2014
Measurement and calculation methods according to EN 61591:1997+A1:2006+A2:2 011+A11:2014+A12:2015

Item number 10028655, 10030099, 10030212, 10030213
Description Symbol
Annual Energy Consumption AEChood
Energy Efficiency class  
Fluid Dynamic Efficiency FDEhood
Fluid Dynamic Efficiency class  
Lighting Efficiency LEhood
Lighting Efficiency class  
Grease Filtering Efficiency GFEhood
Grease Filtering Efficiency class  

air flow at minimum and maximum speed in normal use, intensive or boost excluded|  | 178,8 / 291,3| m³/h
air flow at intensive or boost

setting

|  | –| m³/h
airborne acoustical A-weighted sound power emissions at minimum and maximum speed available in normal use|  | 55 / 60| dB
airborne acoustical A-weighted sound power emissions at intensive or boost setting|  | –| dB
power consumption in off mode| Po| 0,49| W
power consumption in standby mode| Ps| –| W
Contact details| Chal-Tec GmbH, Wallstraße 16, 10179, Berlin, Germany
Item number| 10028655, 10030099, 10030212, 10030213
---|---
Description| Symbol| Value| Unit
Annual Energy Consumption| AEChood| 28| kWh/Jahr
Time increase factor| f| 1,6|
Fluid Dynamic Efficiency| FDEhood| 12,2|
Energy Efficiency Index| EEIhood| 68|
Measured air flow rate at best efficiency point| QBEP| 93,2| m³/h
Measured air pressure at best

efficiency point

| PBEP| 172| Pa
Maximum air flow| Qmax| 299,3| m³/h
Measured electric power input at

best efficiency point

| WBEP| 48,6| W
Nominal power of the lighting system| WL| 3,4| W
Average illumination of the lighting system on the cooking surface| Emiddle| 79| Lux
Measured power consumption in standby mode| Po| –| W
Measured power consumption

off mode

| Ps| 0,49| W
Sound power level| LWA| 52 / 58| dB
Contact details| Chal-Tec GmbH, Wallstraße 16, 10179, Berlin, Germany

NOTES ON ENVIRONMENTAL PROTECTION

  • During cooking, make sure that there is sufficient air supply so that the cooker hood can operate efficiently and with low operating noise.
  • Adjust the fan speed to the amount of steam produced during cooking. Use the intensive mode only when necessary. The lower the fan speed, the less energy is consumed.
  • If large amounts of steam are produced during cooking, select a higher fan speed in good time. If the cooking steam has already dispersed in the kitchen, the cooker hood must be operated longer.
  • Switch off the cooker hood when you no longer need it.
  • Switch off the lighting when you no longer need it.
  • Clean the filter at regular intervals and replace it if necessary to increase the effectiveness of the ventilation system and prevent fire hazards.
  • Always put the lid on when cooking to reduce cooking steam and condensation.

DISPOSAL CONSIDERATIONS
If there is a legal regulation for the disposal of electrical and electronic devices in your country, this symbol on the product or on the packaging indicates that this product must not be disposed of with household waste. Instead, it must be taken to a collection point for the recycling of electrical and electronic equipment. By disposing of it in accordance with the rules, you are protecting the environment and the health of your fellow human beings from negative consequences. For information about the recycling and disposal of this product, please contact your local authority or your household waste disposal service.

MANUFACTURER & IMPORTER (UK)

Manufacturer: Chal-Tec GmbH, Wallstrasse 16, 10179 Berlin, Germany. Importer for Great Britain: Berlin Brands Group UK Ltd PO Box 1145 Oxford, OX1 9UW United Kingdom

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals