POLAR GH332 G-Series Silver Undercounter Fridge with 2 GN Drawers Instruction Manual

June 5, 2024
Polar

POLAR GH332 G-Series Silver Undercounter Fridge with 2 GN Drawers Instruction Manual

Safety Instructions

  • Position on a flat, stable surface.
  • A service agent/qualified technician should carry out installation and any repairs if required. Do not remove any components or service panels on this product.
  • Consult Local and National Standards to comply with the following:
    • Health and Safety at Work Legislation
    • BS EN Codes of Practice
    • Fire Precautions
    • IEE Wiring Regulations
    • Building Regulations
  • O NOT use jet/pressure washers to clean the appliance.
  • DO NOT use the appliance outside.
  • DO NOT use this appliance to store medical supplies.
  • DO NOT stand or support yourself on the base, drawers or doors.
  • DO NOT allow oil or fat to come into contact with the plastic components or door seal. Clean immediately if contact occurs.
  • Always carry, store and handle the appliance in a vertical position and move by holding the base of the appliance.
  • Always switch off and disconnect the power supply to the unit before cleaning.
  • Keep all packaging away from children. Dispose of the packaging in accordance with the regulations of local authorities.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
  • If the power cord is damaged, it must be replaced by a POLAR agent or a recommended qualified technician in order to avoid a hazard.
  • Polar recommend that this appliance should be periodically tested (at least annually) by a Competent Person. Testing should include, but not be limited to: Visual Inspection, Polarity Test, Earth Continuity, Insulation Continuity and Functional Testing.
  • POLAR recommend that this product is connected to a circuit protected by an appropriate RCD (Residual Current Device).

Caution Risk of Fire

  • Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance.
    Warning: Keep all ventilation openings clear of obstruction. Unit should not be boxed in without adequate ventilation.

  • Warning: Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.

  • Warning: Do not damage the refrigerant circuit.

  • Warning: Do not use electrical appliances inside the food storage compartments of the appliance, unless they are the type recommended by the manufacturer.

Product Description

GH332 – Polar G-Series Refrigerated counter with 2 Drawers
GH333 – Polar G-Series Refrigerated Saladette Single Door

Introduction

Please take a few moments to carefully read through this manual. Correct maintenance and operation of this machine will provide the best possible performance from your POLAR product.

Pack Contents

The following is included:

  • POLAR Refrigerator
  • Instruction manual
  • Shelf guides (GH333)
  • Shelves (GH333)
  • Gastronorm spacer bars (GH333)

POLAR prides itself on quality and service, ensuring that at the time of packaging the contents are supplied fully functional and free of damage.

Should you find any damage as a result of transit, please contact your POLAR dealer immediately.

Installation

Note: If the unit has not been stored or moved in an upright position, let it stand upright for approximately 12 hours before operation. If in doubt allow to stand.

  1. Remove the appliance from the packaging.
    Make sure that all protective plastic film and coatings are thoroughly removed from all surfaces.

  2. To optimize performance and longevity, ensure a minimum clearance of 2.5cm is maintained between the unit and walls and other objects, with a minimum 5cm clearance on the top.
    NEVER LOCATE NEXT TO A HEAT SOURCE.
    Note:
    Before using the appliance for the first time, clean the interior with soapy water.
    The appliance is supplied with feet by default. However, castors can be supplied as an option. Castors can be ordered using the code of AJ489.

  3. Set the brakes on the castors to keep the appliance in position. Or, Level the appliance by adjusting the screw feet.

Fitting the Shelves (GH333)

  1. Place one set of shelf guides on either side of the cabinet at the desired height.
  2. Slide the shelf into place.
  3. Slide the floor shelf in place.

GN Pan Layout (GH333)

Note

  • Use the spacer bars provided to fill any gaps (they are not required to support each GN pans).
  • Always close the lid when not in use.
  • The appliance is not intended for the long term storage of food.

Operation

Storing Food
To get the best results from your POLAR appliance, follow these instructions:

  • Only store foodstuffs in the appliance when it has reached the correct operating temperature.
  • Do not place uncovered hot food or liquid inside the appliance.
  • Wrap or cover food where possible.
  • Do not obstruct the fans inside the appliance.
  • Avoid opening the doors for prolonged periods of time.
  • Condensation will form in refrigeration with frequent opening of the doors and on hot humid days, please ensure condensation is allowed to drain properly or is wiped dry.

Turn On

  1. Ensure the power switch is set to [O] and turn on at the socket.
  2. Switch on the Power [I]. The current temperature within the appliance is displayed.

Control Panel

Set the Operating Temperature

  1. Hold the SET button for 3 seconds. The value of the current set point will be displayed.
  2. Press the or buttons to display the required temperature.
  3. Press the SET button to store the temperature.

Manual Defrost

  • The appliance will automatically run a defrost cycle every six hours.
  • To manually defrost the appliance: Press and hold the defrost button “aux” for 2 seconds to begin a manual defrost. The defrost light illuminates.

Cleaning, Care & Maintenance


Defrost appliance at least every 3 months, more often if required.
Switch off and disconnect from the power supply before cleaning.

  • Clean the interior of the appliance as often as possible.
  • Do not use abrasive cleaning agents. These can leave harmful residues.
  • Clean the door seal with warm soapy water.
  • Always wipe dry after cleaning.
  • Do not allow water used in cleaning to run through the drain hole into the evaporation pan.
  • Take care when cleaning the rear of the appliance. Sharp edges can cut.
  • A POLAR agent or qualified technician must carry out repairs if required.

Condenser Cleaning

  • The condenser is part of the refrigeration system. The condenser requires monthly cleaning.
  • Always disconnect power supply before carrying out Routine Maintenance.
  • Failure to clean the condenser will reduce the performance and life of your Polar unit and may invalidate your warranty.
  • These models have a removable filter which can be cleaned with a vacuum cleaner.

Troubleshooting

If your POLAR appliance develops a fault, please check the following table before making a call to the Helpline or your POLAR dealer.

Fault Probable Cause Solution
The appliance is not working The unit is not switched on Check the unit is

plugged in correctly and switched on
Plug or lead are damaged| Call POLAR agent or qualified Technician
Fuse in the plug has blown| Replace the fuse
Power supply| Check power supply
The appliance turns on, but the temperature is too high/low| Too much ice on the evaporator| Defrost the appliance
Condenser blocked with dust| Clean the Condenser
Doors are not shut properly| Check doors are shut and seals are not damaged
Appliance is located near a heat source or air flow to the condenser is being interrupted| Move the refrigerator to a more suitable location
Ambient temperature is too high| Increase ventilation or move appliance to a cooler position
Unsuitable foodstuffs are being stored in the appliance| Remove any excessive hot foodstuffs or blockages to the fan
Appliance is overloaded| Reduce the amount of food stored in the appliance
The appliance is leaking water| The appliance is not properly levelled| Adjust the screw feet to level the appliance (if applicable)
The discharge outlet is blocked| Clear the discharge outlet
Movement of water to the drain is obstructed| Clear the floor of the appliance (if applicable)
The water container is damaged| Call POLAR agent or qualified Technician
The drip tray is overflowing| Empty the drip tray (if applicable)
The appliance is unusually loud| Loose nut/screw| Check and tighten all nuts and screws
The appliance has not been installed in a level or stable position| Check installation position and change if necessary

Technical Specifications


Model

| ****

Voltage

| ****

Power

| ****

Current

| Temperature Range| Net Capacity (Litres)| ****

Refrigerant

| Dimensions H x W x D mm| Weight (kg)
---|---|---|---|---|---|---|---|---
GH332| 230V 50Hz| 100W| 1.2A| 2°C ~ 8°C| 65| R600a 45g| 868.5 x 478 x 700| 46
GH333| 230V 50Hz| 125W| 1.2A| 2°C ~ 8°C| 109| R600a 45g| 857.5 x 438 x 700| 36

Electrical Wiring

POLAR appliances are supplied with a 3 pin BS1363 plug and lead.

The plug is to be connected to a suitable mains socket.

POLAR appliances are wired as follows:

  • Live wire (coloured brown) to terminal marked L
  • Neutral wire (coloured blue) to terminal marked N
  • Earth wire (coloured green/yellow) to terminal marked E

This appliance must be earthed.

If in doubt consult a qualified electrician.

Electrical isolation points must be kept clear of any obstructions. In the event of any emergency disconnection being required they must be readily accessible.

Disposal

EU regulations require refrigeration product to be disposed of by specialist companies who remove or recycle all gasses, metal and plastic components.

Consult your local waste collection authority regarding disposal of your appliance. Local authorities are not obliged to dispose of commercial refrigeration equipment but may be able to offer advice on how to dispose of the equipment locally.

Alternatively call the POLAR helpline for details of national disposal companies within the EU.

Compliance

The WEEE logo on this product or its documentation indicates that the product must not be disposed of as household waste. To help prevent possible harm to human health and/or the environment, the product must be disposed of in an approved and environmentally safe recycling process. For further information on how to dispose of this product correctly, contact the product supplier, or the local authority responsible for waste disposal in your area.

POLAR parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international, independent, and federal authorities.

POLAR products have been approved to carry the following symbol:

All rights reserved. No part of these instructions may be produced or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written permission of POLAR.
Every effort is made to ensure all details are correct at the time of going to press, however, POLAR reserve the right to change specifications without notice.

DECLARATION OF CONFORMITY

Equipment Type Model

Refrigerated Counter with 6 drawers
Refrigerated Counter with 9 drawers Refrigerated Saladette, Single Door| Freezer Saladette, Single Door with Castors Saladette with 2 GN Drawers
Single Door Saladette Preparation Counter| FA440 (-E & -A)
FA441 (-E & -A)
FA442 (-E & -A)| FA443 (-E & -A)
GH332 (-E & -A)
GH333 (-E & -A)
Application of Territory Legislation & **Council Directives(s)**

| Machinery Directive 2006/42/EC
Supply of Machinery (Safety) Regulations 2008
EN 60335-1:2012 +A11:2014 +A13:2017 +A1:2019
+A4:2019 +A2:2019
EN 60335-2-89:2010 +A1:2016 +A2:2017
EN 62233:2008
Electro-Magnetic Compatibility (EMC) Directive

2014/30/EU – recast of 2004/108/EC
Electromagnetic Compatibility Regulations 2016
(S.I. 2016/1091)
EN 55014-1: 2017 +A11:2020
EN55014-2:2015
EN IEC 61000-3-2: 2019
EN 61000-3-3:2013 +A1:2019
Restriction of Hazardous Substances Directive
(RoHS) 2015/863 amending Annex II to Directive
2011/65/EU
Restriction of the Use of Certain Hazardous
Substances in Electrical and Electronic
Equipment Regulations 2012 (S.I. 2012/3032)

| Electrical Safety
IEC 60335-1:2010 +A1:2013 +A13:2016

IEC 60335-2-89:2010 +A1:2012 +A2:2015

EN 62233:2008

Electromagnetic Compatibility

EN 55014-1: 2017 +A11:2020

EN55014-2:2015

EN IEC 61000-3-2: 2019

EN 61000-3-3:2013 +A1:2019

Producer Name| Polar

I, the undersigned, hereby declare that the equipment specified above conforms to the above Territory Legislation, Directive(s) and Standard(s).

12 th August 2021

| |
Ashley Hooper| Eoghan Donnellan| Nerida Pearse
Technical & Quality Manager| Commercial Manager/ Importer| Commercial Manager/ Responsible Supplier
Fourth Way,
Avonmouth, Bristol, BS11 8TB United Kingdom| 42 North Point
Business Park
New Mallow Road Cork Ireland| 15 Bagdally Road, Campbelltown

NSW 2560

UK|

+44 (0)845 146 2887

---|---
Eire
NL| 040 – 2628080
FR| 01 60 34 28 80
BE-NL| 0800-29129
BE-FR| 0800-29229
DE| 0800 – 1860806
IT| N/A
ES| 901-100 133
PT| [email protected]

QR Code
http://www.polar-refrigerator.com/

GH332-GH333_ML_A5_v1_20210930

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Polar User Manuals

Related Manuals