PRODUCT SPECIFICATIONS

SPECIFICATIONS

120 V, 60 Hz
Duct diameter – 4 in.
SPECIFICATIONS

Sound output – 2.0 Sones
Power consumption – 27.6 W
Weight – 13 lbs.

TYPICAL INSTALLATION

AKICON BPT14-80CL Bathroom Ventilation Fan with Light-fig
1

PACKAGE CONTENTS

AKICON BPT14-80CL Bathroom Ventilation Fan with Light-fig
2

PART DESCRIPTION QUANTITY
A Fan housing 1
B Light/rim assembly 1
PART DESCRIPTION QUANTITY
--- --- ---
C Glass globe 1
D LED light bulbs 2

HARDWARE CONTENTS (not actual size)

SAFETY INFORMATION

READ AND SAVE THESE INSTRUCTIONS
Please read and understand this entire manual before attempting to assemble, operate or install the product.

  1. Always disconnect the power supply prior to servicing the fan, motor or junction box.
  2. Follow all local building, safety and electrical codes, as well as NEC (National Electrical Code) and OSHA (Occupational Safety and Health Act).
  3. Electric service supply must be 120 volts, 60Hz.
  4. This unit must be properly grounded.
  5.  Do not bend or kink the power wires.
  6. Exercise care to not damage existing wiring when cutting or drilling into walls or ceilings.
  7.  Do not use this fan with any solid state control device. Such as a remote control, dimmer switch, or certain timers. Mechanical timers are not solid state devices.
  8.  This ventilation fan is approved for use over a bathtub or shower when installed in a GFCI protected circuit. Do not use fans over a bathtub or shower that are not approved for that application and marked accordingly.
  9. Do not install in a cooking area.
  10. Do not use to exhaust hazardous or explosive vapors.
  11. Fans should always be vented to the exterior and in compliance with local codes.
  12. Do not install in a ceiling with insulation greater than R40.
  13.  Duct work should be installed in a straight line with minimal bends.
  14. Duct work size must be the same size as the discharge and should not be reduced. Reducing the duct size, may increase fan noise.
  15.  Prior to servicing or cleaning this unit, shut off power supply at the panel and lock to prevent the power from being turned on. If the panel cannot be locked, clearly mark the panel with a warning tag to prevent the power from being turned on.
  16.  Use this unit in the manner intended by the manufacturer. If you have any questions, please call the manufacturer.

PREPARATION

WARNING: Turn off electricity at breaker box before beginning installation.
Carefully remove unit from carton.
Before beginning assembly of product, make sure all parts are present. Compare parts with package contents list and hardware contents. If any part is missing or damaged, do not attempt to assemble the product.

Check area above installation location to be sure that wiring can run to the planned location and that
Inspect duct work and wiring before proceeding with installation.
Before installation, provide inspection and future maintenance access at a location that will not interfere with installation work.
Do not attempt to install this fan in a wall or vaulted ceiling. This fan is for standard horizontal ceiling installation only.
You may need the help of a second person to install this fan: one person on the attic side and one on the room side.
Tools required for assembly (not included): Electric Drill, Drill Bits, Phillips Screwdriver, Utility Knife
Other supplies you will need (not included): Duct Tape
Note: Installations may vary depending on how the previous bath fan was installed. Supplies necessary for the installation of your bath fan are not all included; however, most are available at your local home improvement or hardware store

DIMENSIONS

Ceiling Opening (L) Ceiling Opening (W) Ceiling Opening (H)
8-1/2 in. 8-5/16 in. 6-11/16 in.

WIRING DIAGRAM

QUICK CONNECTOR INSTRUCTIONS
To be sold only with installation instructions.
WARNING: Wiring must comply with all appliable electrical codes. Turn OFF power before removing or installing connectors.
WARNING: COPPER TO COPPER ONLY. Do not use aluminum wire.
CAUTION: Accessory part (quick connector) should meet installation instructions below.
NOTE: The connector is reusable on solid wires of the same wire gage or smaller. Do not reuse the connector on stranded wires.

  • Strip wires 3/8 in. – 1/2 in.
  • Grip the wire firmly and push the stripped end of the wire into the open port of the connector. Use only one conductor per port.
  • Verify the stripped end of the wires is fully inserted to the back of the connector.

NEW CONSTRUCTION ASSEMBLY INSTRUCTIONS

AKICON BPT14-80CL Bathroom Ventilation Fan with Light-fig
6 AKICON BPT14-80CL Bathroom Ventilation
Fan with Light-fig 16 AKICON
BPT14-80CL Bathroom Ventilation Fan with Light-fig 17 AKICON BPT14-80CL Bathroom Ventilation Fan with Light-
fig 18

EXISTING CONSTRUCTION ASSEMBLY INSTRUCTIONS

AKICON BPT14-80CL Bathroom Ventilation Fan with Light-fig
19 4. Mount the fan housing (A) to joist using the long wood screws (AA) on both sides.

Hardware Used

  • Long wood screw

5. Remove wiring box cover (5.1). Pull the house wires through the wire box cover hole. Using a quick connector, secure 120 V AC house wiring from the wall switch to the fan as shown in the wiring diagram on page 5. 14 AWG is the smallest conductor that should be used for branch-circuit wiring.
Carefully push the connected wires back into the wiring box housing. Reattach the wiring box cover (5.1). CAUTION: If the electrical wires do not match the colors listed, you must determine what each house wire represents before connecting. You may need to consult an electrical contractor to determine safely.

6. Install a circular 4 in. duct (6.1) (not included) and secure it with duct tape or clamps (neither included).
Finish ceiling work. Ceiling hole should be aligned with edge of fan housing (A).

7. Plug light/rim assembly (B) into the fan housing (A). 8. Slide light/rim assembly (B) onto threaded studs (8.1).Secure with wing nuts (BB).

Hardware Used

  • Wing nut

9. Screw two LED light bulbs (D) into the light/rim assembly (B).

10. Place glass globe (C) up to the light/rim/assembly (B). Align the three rim locking clips on the light/rim assembly (B) with the indents on the glass globe (C). Push glass globe (C) into the light/rim assembly (B) and rotate clock-wise until glass globe stops (open to close distance is 5-3/16″) to lock into place.

AKICON BPT14-80CL Bathroom Ventilation Fan with Light-fig
13CARE AND MAINTENANCE

WARNING: Disconnect power supply before servicing. See SAFETY INFORMATION before proceeding. Routine maintenance should be done at least once a year.

  • Wash grille with mild soap and water, dry with a cloth.
  • Remove excess dirt and dust from the fan housing with a vacuum cleaner.
  •  Do not use solvents, thinner or harsh chemicals for cleaning the fan.
  •  Do not allow water to enter the motor.
  •  Do not immerse resin parts in water over 140º F.

TROUBLESHOOTING

PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION




The fan seems louder than it should

| CFM too great| Be sure the CFM rating on the fan matches the size of your room


Damper not working properly or damaged

| Check damper to ensure it is opening and closing properly. If the damper has become damaged, please call Customer Service
Bend in duct too close to fan discharge| Be sure you do not have any sharp bends in duct closer than 18 in. to the fan discharge
****| Use recommended size ducting to reduce fan noise
Fan housing not securely attached| Be sure the fan is securely attached to your ceiling joists





The fan is not clearing the room

| ****


| Be sure a door or window is slightly ajar or draw air out of the room without enough




| Be sure the CFM rating on the fan matches the requirements for your room size

NOTE: Using a tissue is not an accurate method for determining if the fan is operating properly. If the fan clears steam from the room within approximately 15 minutes of completing your shower, then the fan is operating properly.

LIMITED 5-YEAR WARRANTY

This warranty does not cover products that have been abused, altered, damaged, misused, cut or worn. This warranty does not cover use in commercial applications. Use only manufacturer-supplied genuine warranty repair replacement parts to repair this fan. Use of non-genuine repair parts will void your warranty. The manufacturer DISCLAIMS all other implied or express warranties including all warranties of   have other rights that vary from state to state.

This warranty is limited to the replacement of defective parts only. Labor charges and/or damage incurred during installation, repair, replacement as well as incidental and consequential damages connected with the above are excluded. Any damage to this product as a result of neglect, misuse, accident, imporper installation or use other than the purpose SHALL VOID THIS WARRANTY.

Shipping costs for return product as part of a claim on the warranty must be paid for by the customer.

Inquiries regarding warranty claims can be directed to 1-302-213-4406,1-302-526-0542, 8 a.m. – 6 p.m., EST , Monday – Thursday, 8 a.m. – 5 p.m., EST, Friday.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

AKICON User Manuals

Related Manuals