AKICON AK1390N3-W Bathroom Ventilation Fan with Light User Guide

June 16, 2024
AKICON

AKICON logo USE AND CARE GUIDE
AK1390N3-W/B/SAKICON AK1390N3 W Bathroom Ventilation Fan with
Light

Bathroom Ventilation Fan with Light
READ AND SAVE THESE INSTRUCTIONS
Questions, problems, missing parts? Before returning to the store, call AKICON Customer Service
8 a.m.-6 p.m.,EST, Monday-Friday
TOLL FREE: +1 (888) 828 2025
service@akiconshop.com
AKICONSHOP.COM

PRODUCT SPECIFICATIONS

SPECIFICATIONS
120 V, 60 Hz
Power consumption – 26 W
Duct diameter – 4 in.
Weight – 2.8KG
Sound output – 1.5 Sones
LED Light – 15W
CCT – 2700K/4000K/5500K
Lumen-1000lm
Night Light – 5W

TYPICAL INSTALLATION

AKICON AK1390N3 W Bathroom Ventilation Fan with Light -
INSTALLATION

PACKAGR CONTENTS

AKICON AK1390N3 W Bathroom Ventilation Fan with Light - PACKAGE
CONTENTS

PART DESCRIPTION QUANTITY
A Fan housing 1
B Duct adaptor 1
C Light components 1

HARDWARE CONTENTS (not actual size)

SAFETY INFORMATION

READ AND SAVE THESE INSTRUCTIONS
Please read and understand this entire manual before attempting to assemble, operate or install the product.

  1. Always disconnect the power supply prior to servicing the fan, motor or junction box.
  2. Installation work must be carried out by a qualified person(s) in accordance to all local and safety codes including the rules for fire-rated construction.
  3. Follow all local building, safety and electrical codes, as well as NEC (National Electrical Code) and OSHA (Occupational Safety and Health Act).
  4. Electric service supply must be 120 volts, 60HZz.
  5. This unit must be properly grounded.
  6. Do not bend or kink the power wires.
  7. Exercise care to not damage existing wiring when cutting or drilling into walls or ceilings.
  8. Sufficient air supply is required for proper combustion and the exhaustion of gases through the chimney (flue) of fuel burning equipment to prevent back-drafting. See the standards of NFPA (National Fire Protection Association) and ASHRAE (American Society for Heating Refrigeration and Air Conditioning Engineers) and the local building code authorities.
  9. Donotuse this fan with any solid state control device. Such as a remote control, dimmer switch, or certain timers. Mechanical timers are not solid state devices.
  10. This ventilation fan is approved for use over a bathtub or shower when installed in a GFCI protected circuit. Do not use fans over a bathtub or shower that are not approved for that application and marked accordingly.
  11. Do not install in a cooking area.
  12. Do not use to exhaust hazardous or explosive vapors.
  13. Fans should always be vented to the exterior and in compliance with local codes.
  14. Do not install in a ceiling with insulation greater than R40.
  15. Duct work should be installed in a straight line with minimal bends.
  16. Duct work size must be the same size as the discharge and should not be reduced. Reducing the duct size, may increase fan noise.
  17. Prior to servicing or cleaning this unit, shut off power supply at the panel and lock to prevent the power from being turned on. If the panel cannot be locked, clearly mark the panel with a warning tag to prevent the power from being turned on.
  18. Use this unit in the manner intended by the manufacturer. If you have any questions, please call the manufacturer (customer service number located on first page).
  19. The fan is intended to be mounted at least 7 ft. (2.1 m) above the floor.

PREPARATION

WARNING: Turn off electricity at breaker box before beginning installation.
Carefully remove unit from carton.
Before beginning assembly of product, make sure all parts are present. Compare parts with package contents list and hardware contents. If any part is missing or damaged, do not attempt to assemble the product.
Check area above installation location to be sure that wiring can run to the planned location and that duct work can be run and the area is sufficient for proper ventilation.
Inspect duct work and wiring before proceeding with installation.
Before installation, provide inspection and future maintenance access at a location that will not interfere with installation work.
Do not attempt to install this fan in a wall or vaulted ceiling. This fan is for standard horizontal ceiling installation only.
You may need the help of a second person to install this fan: one person on the attic side and one on the room side.
Tools required for assembly (not included): Electric Drill, Drill Bits, Phillips Screwdriver, Utility Knife Other supplies you will need (not included): Duct Tape
Note: Installations may vary depending on how the previous bath fan was installed. Supplies necessary for the installation of your bath fan are not all included; however, most are available at your local home improvement or hardware store.

DIMENSIONS

Ceiling Opening (L) Ceiling Opening (W)
7-1/2 in. 7-3/4 in.

WIRING DIAGRAM

AKICON AK1390N3 W Bathroom Ventilation Fan with Light - WIRING
DIAGRAM

QUICK CONNECTOR INSTRUCTIONS
To be sold only with installation instructions.
WARNING: Wiring must comply with all appliable electrical codes. Turn OFF power before removing or installing connectors.
WARNING: COPPER TO COPPER ONLY. Do not use aluminum wire.
CAUTION: Accessory part (quick connector) should meet installation instructions below.
NOTE: The connector is reusable on solid wires of the same wire gage or smaller. Do not reuse the connector on stranded wires.

  • Strip wires 3/8 in. – 1/2 in.
  • Grip the wire firmly and push the stripped end of the wire into the open port of the connector. Use only one conductor per port.
  • Verify the stripped end of the wires is fully inserted to the back of the connector.

AKICON AK1390N3 W Bathroom Ventilation Fan with Light -
INSTRUCTIONS

NOTE: Important wire information. Maximum temperature rating 221°F (105°C). 600 volts maximum for building wire and 1,000 volts maximum for building wire and 1,000 volts maximum in signs and lighting fixtures.
The acceptable wire range includes: Solid: 12-18 AWG.

NEW CONSTRUCTION ASSEMBLY INSTRUCTIONS

NEW CONSTRUCTION — ATTACHING TO THE JOIST
BEFORE INSTALLATION -— Turn off power source. Review all safety precautions.

  1. Place the fan housing (A) next to a ceiling joist or wall stud (1.1). The fan housing (A) should be level and perpendicular to the joist or wall stud (1.1). Allow for thickness of ceiling board (1.2) used in your application. DO NOT flush mount to joist or wall stud (1.1). Bottom of fan housing (A) should be flush with the ceiling board (1.2).

  2. Mount the fan housing (A) to joist using the long wood screws (AA) on both sides.AKICON AK1390N3 W Bathroom Ventilation Fan with Light - ASSEMBLYHardware Used

  3. Attach the adaptor B to the housing A

  4. Remove wiring box cover (4.1). Pull the house wires through the wire box cover hole. Using a quick connector, secure 120 V AC house wiring from the wall switch to the fan as shown in the wiring diagram on page 5. 14 AWG is the smallest conductor that should be used for branch-circuit wiring.
    Carefully push the connected wires back into the wiring box housing. Reattach the wiring box cover (4.1).
    CAUTION: If the electrical wires do not match the colors listed, you must determine what each house wire represents before connecting. You may need to consult an electrical contractor to determine safely.AKICON AK1390N3 W
Bathroom Ventilation Fan with Light - ASSEMBLY 1

  5. Install a circular 4 in. duct (5.1) (not included) and secure it with duct tape or clamps (neither included).Finish ceiling work. Ceiling hole should be aligned with edge of fan housing (A).

  6. AKICON AK1390N3 W Bathroom Ventilation Fan with Light - ASSEMBLY 2Plug the fan motor plug into the fan housing(4 hole to 4 hole). Plug the LED light panel plug into the housing as well.(2 hole to 2 hole)

  7. AKICON AK1390N3 W Bathroom Ventilation Fan with Light - ASSEMBLY 3Attach LED light panel C by pinching the mounting springs andinserting them into the narrow rectanqular slots in the fanhousing. Turn on power source. Test the unit.

EXISTING CONSTRUCTION ASSEMBLY INSTRUCTIONS

Installing the fan housing in an existing building REQUIRES AN ACCESSIBLE AREA (attic or crawl space) above the planned installation location and existing duct and wiring.
BEFORE INSTALLATION -— Turn off power source. Review all safety precautions. Remove existing fan.

  1. Measure the opening to ensure it is large enough to accommodate the new fan housing (7-1/2 in. x 7-1/4 in.).

  2. If this fan is not replacing an old fan, be sure to cut a 7-1/2 in. x 7-3/4 in. opening for the fan housing.AKICON AK1390N3 W Bathroom Ventilation Fan with Light - ASSEMBLY 4

  3. Place the fan housing (A) next to a ceiling joist or wall stud (3.1). The fan housing (A) should be level and perpendicular to the joist or wall stud (3.1). Allow for thickness of ceiling board (3.2) used in your application. DO NOT flush mount to joist or wall stud (3.1). Bottom of fan housing (A) should be flush with the ceiling board (3.2).AKICON AK1390N3 W Bathroom Ventilation Fan with Light - ASSEMBLY 5

  4. Mount the fan housing (A) to joist using the long wood screws (AA) on both sides.
    Hardware UsedAKICON AK1390N3 W Bathroom Ventilation Fan with Light -
ASSEMBLY 10

  5. Remove wiring box cover (5.1). Pull the house wires through the wire box cover hole. Using a quick connector, secure 120 V AC house wiring from the wall switch to the fan as shown in the wiring diagram on page 5. 14 AWG is the smallest conductor that should be used for branch- circuit wiring. Carefully push the connected wires back into the wiring box housing. Reattach the wiring box cover (5.1).AKICON AK1390N3 W Bathroom Ventilation Fan with Light - ASSEMBLY 7 CAUTION: If the electrical wires do not match the colors listed, you must determine what each house wire represents before connecting. You may need to consult an electrical contractor to determine safely.

  6. Install a circular 4 in. duct (6.1) (not included) and secure it with duct tape or clamps (neither included).
    Finish ceiling work. Ceiling hole should be aligned with edge of fan housing (A).

  7. Plug the fan motor plug into the fan housing(4 hole to 4 hole). Plug the LED light panel plug into the housing as well.(2 hole to 2 hole)AKICON AK1390N3 W Bathroom Ventilation Fan with Light - ASSEMBLY 8

  8. Attach LED light panel C by pinching the mounting springs andinserting them into the narrow rectanqular slots in the fanhousing.Turn on power source. Test the unit.AKICON AK1390N3 W Bathroom Ventilation Fan with Light - ASSEMBLY 9

CARE AND MAINTENANCE

WARNING: Disconnect power supply before servicing. See SAFETY INFORMATION before proceeding.
Routine maintenance should be done at least once a year.

  • Wipe grille with a dry cloth.
  • Remove excess dirt and dust from the fan housing with a vacuum cleaner.
  • Do not use solvents, thinner or harsh chemicals for cleaning the fan.
  • Do not allow water to enter the motor.
  • Do not immerse resin parts in water over 140º F.

TROUBLESHOOTING

PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
The fan seems louder than it should CFM too great Be sure the CFM rating on

the fan matches the size of your room
Damper not working properly or damaged| Check damper to ensure it is opening and closing properly. If the damper has become damaged, please call Customer Service
Bend in duct too close to fan discharge| Be sure you do not have any sharp bends in duct closer than 18 in. to the fan discharge
Fan discharge reduced to fit smaller duct| Use recommended size ducting to reduce fan noise
Fan housing not securely attached| Be sure the fan is securely attached to your ceiling joists
The fan is not clearing the room| Insufficient intake airflow within room| Be sure a door or window is slightly ajar or opened to allow airflow. The fan is not able to draw air out of the room without enough airflow to draw from
Insufficient CFM|  Be sure the CFM rating on the fan matches the requirements for your room size
NOTE: Using a tissue is not an accurate method for determining if the fan is operating properly. If the fan clears steam from the room within approximately 15 minutes of completing your shower, then the fan is operating properly.

LIMITED 3 -YEAR WARRANTY

lf this product fails due to a defect in materials or workmanship at any time during the first ONE years of ownership, the manufacturer will replace it free of charge, postage-paid at their option. This warranty does not cover products that have been abused, altered, damaged, misused, cut or worn. This warranty does not cover use in commercial applications. Use only manufacturer-supplied genuine warranty repair replacement parts to repair this fan. Use of non- genuine repair parts will void your warranty. The manufacturer DISCLAIMS all other implied or express warranties including all warranties of merchantability and/or fitness for a particular purpose. As some states do not allow exclusions or limitations on an implied warranty, the above exclusions and limitations may not apply. This warranty gives you specific legal rights, and you may have other rights that vary from state to state.
This warranty is limited to the replacement of defective parts only. Labor charges and/or damage incurred during installation, repair, replacement as well as incidental and consequential damages connected with the above are excluded. Any damage to this product as a result of neglect, misuse, accident, imporper installation or use other than the purpose SHALL VOID THIS WARRANTY.
Shipping costs for return product as part of a claim on the warranty must be paid for by the customer.
Inquiries regarding warranty claims can be directed to +1 (888) 828 2025, 8 a.m. -6p.m., EST , Monday Thursday,
8a.m.-5p.m., EST, Friday.

AKICON logoPrinted in China