AKICON AK-SW-FLHT Humidity Switch User Guide
- June 1, 2024
- AKICON
Table of Contents
Humidity Switch User Guide
Model No. AK-SW-FLHT
Specifications
Type | Humidity Switch |
---|---|
Model | AK-SW-FLHT |
Rated Voltage | 100-240VAC 50/60Hz |
Fan | 2(2)A |
LED | Max 50W each way |
Product Size | 4.923.151.48 Inch |
Time Range | 50%-90% |
Humidity Range | 5-60 Minutes |
Operation
- Open the cover plate to set the humidity and time values.
- When humidity and/or time is set, please refer to the mode description in the table on the back of the page.
- If humidity and time values are not set, you need to manually turn ON/OFF the fan.
Wiring Diagram
Use wire-nuts to connect switch wires to your home wires according to remark of switch wires. Confirm whether the wire are connected tightly
WARNING
- Turn off power at circuit breaker before installation.
- A neutral wire is needed to power the switch.
- Use COPPER WIRE ONLY.
- If you are not sure about any part of these instructions, consult an electrician.
Operating Mode Descriptions
Modes| Humidity| Time| When/Where to USE| Situation
1| Situation 2| Situation 3
---|---|---|---|---|---|---
OFF| ON (50%-90%)| OFF| ON (5- 60Min.)
Auto Mode – A
(Humidity sensing takes the
dominant role)| | √| | √| For bathrooms, shower rooms, laundry rooms, and
areas where significant changes in humidity can occur.| When the environmental
humidity exceeds the set value, the exhuast fan will turn ON; when the
humidity falls below the set value, the fan will turn OFF after 5 minutes.|
When the fan is manually turned OFF during operation, the humidity sensor
pauses for 10 minutes. If the humidity is higher than the set value after 10
minutes, the fan will turn ON. If it’s below the set value, the fan will turn
OFF after 5 minutes.| If the fan is manually turned ON
again within a stationary period
of 10 minutes, the fan will operate based on the set time value. If the
humidity is below the set humidity value after the set time value, the fan
will be turned off.
Auto Mode – B
(Humidity sensing takes the
dominant role)| | √| √| | For bathrooms, shower rooms, laundry rooms, and
areas where significant changes in humidity can occur.| When the environmental
humidity exceeds the set value, the exhuast fan will turn ON; when the
humidity falls below the set value, the fan will turn OFF after 5
minutes.| When the fan is manually turned OFF during operation, the umidity
sensor pauses for 10 minutes. If the humidity is higher than the set value
after 10 minutes, the fan will turn ON. If it’s below the set value, the fan
will turn OFF after 5 minutes.| If the fan is manually turned ON
again within a stationary period
of 10 minutes, the fan will turn
ON. It will stay on until you manually turn the fan OFF.
Manual Mode – A| √| | | √| Basements, bathrooms, and rooms requiring regular
ventilation.| The fan needs to be manually turned ON, and the fan will
stay ON according to the set time value.| |
Manual Mode – B| √| | √| | Any time you want to turn the fan ON/OFF.| The fan
needs to be manually
turned ON/OFF.| |
LIMITED 3 YEAR WARRANTY
This device is warranted to be free of material and workmanship defects for 3
years from the date of purchase. Original receipt or proof of purchase from an
authorized retailer must be presented upon warranty claim. ALL claims must be
verified and approved by Akicon, Inc.
Warranties from other Akicon products may vary. This warranty i s
nontransferable and does not cover normal wear and tear or any malfunction,
failure, or defect resulting from misuse, abuse, neglect, alteration, modif i
cation, or improper installation.