AKICON AK-SW-FLHT Humidity Switch User Guide

June 1, 2024
AKICON

AKICON Logo Humidity Switch User Guide
Model No. AK-SW-FLHT

Specifications

Type Humidity Switch
Model AK-SW-FLHT
Rated Voltage 100-240VAC 50/60Hz
Fan 2(2)A
LED Max 50W each way
Product Size 4.923.151.48 Inch
Time Range 50%-90%
Humidity Range 5-60 Minutes

AKICON AK-SW-FLHT Humidity Switch - Specifications

Operation

  1. Open the cover plate to set the humidity and time values.
  2. When humidity and/or time is set, please refer to the mode description in the table on the back of the page.
  3. If humidity and time values are not set, you need to manually turn ON/OFF the fan.

AKICON AK-SW-FLHT Humidity Switch - Operation

Wiring Diagram

Use wire-nuts to connect switch wires to your home wires according to remark of switch wires. Confirm whether the wire are connected tightlyAKICON AK-SW-
FLHT Humidity Switch - Wiring Diagram

WARNING

  • Turn off power at circuit breaker before installation.
  • A neutral wire is needed to power the switch.
  • Use COPPER WIRE ONLY.
  • If you are not sure about any part of these instructions, consult an electrician.

Operating Mode Descriptions

Modes| Humidity| Time| When/Where to USE| Situation 1| Situation 2| Situation 3
---|---|---|---|---|---|---
OFF| ON (50%-90%)| OFF| ON (5- 60Min.)
Auto Mode – A
(Humidity sensing takes the
dominant role)| | √| | √| For bathrooms, shower rooms, laundry rooms, and areas where significant changes in humidity can occur.| When the environmental humidity exceeds the set value, the exhuast fan will turn ON; when the humidity falls below the set value, the fan will turn OFF after 5 minutes.| When the fan is manually turned OFF during operation, the humidity sensor pauses for 10 minutes. If the humidity is higher than the set value after 10 minutes, the fan will turn ON. If it’s below the set value, the fan will turn OFF after 5 minutes.| If the fan is manually turned ON
again within a stationary period
of 10 minutes, the fan will operate based on the set time value. If the humidity is below the set humidity value after the set time value, the fan will be turned off.
Auto Mode – B
(Humidity sensing takes the
dominant role)| | √| √| | For bathrooms, shower rooms, laundry rooms, and areas where significant changes in humidity can occur.| When the environmental humidity exceeds the set value, the exhuast fan will turn ON; when the humidity falls below the set value, the fan will turn OFF after 5
minutes.| When the fan is manually turned OFF during operation, the  umidity sensor pauses for 10 minutes. If the humidity is higher than the set value after 10 minutes, the fan will turn ON. If it’s below the set value, the fan will turn OFF after 5 minutes.| If the fan is manually turned ON
again within a stationary period
of 10 minutes, the fan will turn
ON. It will stay on until you manually turn the fan OFF.
Manual Mode – A| √| | | √| Basements, bathrooms, and rooms requiring regular ventilation.| The fan needs to be manually turned ON, and the fan will
stay ON according to the set time value.| |
Manual Mode – B| √| | √| | Any time you want to turn the fan ON/OFF.| The fan needs to be manually
turned ON/OFF.| |

LIMITED 3 YEAR WARRANTY

This device is warranted to be free of material and workmanship defects for 3 years from the date of purchase. Original receipt or proof of purchase from an authorized retailer must be presented upon warranty claim. ALL claims must be verified and approved by Akicon, Inc.
Warranties from other Akicon products may vary. This warranty i s nontransferable and does not cover normal wear and tear or any malfunction, failure, or defect resulting from misuse, abuse, neglect, alteration, modif i cation, or improper installation.