Drywall screwdriver | TBS 710 E |
---|---|
Art. No | 58132 |
Service connection | 230 V ~ 50 Hz |
Rated input | 710 W |
No-load speed | 0-4000 min -1 |
Tool reception | 6,35 mm |
Torque max. | 9,8 Nm |
Weight | 1,6 kg |
Noise details
Sound pressure level LpA| 85 dB (A)
Sound power level LWA| 96 dB (A)
Measured according to EN 60745; Uncertainty K = 3 dB (A)
Wear ear protectors!
Vibration details
Vibration total values (triaxial vector sum) deter- mined according to EN
60745
Screwing: Vibration emission
value ah
| 0,79 m/s2
Uncertainty K = 1,5 m/s2
WARNING: The vibration emission level will vary because of the ways in
which a power tool can be used and may increase above the level given in this
information sheet.
The vibration emission level may be used to compare one tool with another It
may be used for a preliminary assessment of exposure. An accurate estimate of
the vibratory load
should also take into account the times when the tool is shut down or when it
is running but not actually in use. This may significantly reduce the
vibratory load over the total working period. Identify additional safety
measures to protect the operator from the effects of vibration such as:
maintain the tool and the accessories, keep the hands warm, organization of
work patterns.
Read and understand the operating instructions before using the appliance. Familiarise with the control elements and how to use the appliance properly. Abide by all the safety measures stated in the service manual. Act responsibly toward third parties. The operator is responsible for accidents or risks to third parties. Persons over 16 years of age can only work on the appliance. An exception includes youngsters trained in order to reach knowledge under supervision of the trainer during occupational education. In case of any doubts about connection and operation refer please to our customer center.
Specified Conditions Of Use
The drywall screwdriver is exclusively intended for fastening gypsum and wooden plasterboards in interior construction. Do not use this product in any other way as stated for normal use. Not observing general regulations in force and instructions from this manual does not make the manufacturer liable for damages.
Emergency procedure
Conduct a first-aid procedure adequate to the injury and summon qualified medical attendance as quickly as possible. Protect the injured person from further harm and calm them down. If you seek help, state the following pieces of information: 1. Accident site, 2. Accident type, 3. Number of injured persons, 4. Injury type(s)
WARNING Read all safety warnings and all instructions. Failure to follow
the warnings and instructions may result in electric shock, fire and/or
serious injury.
Save all warnings and instructions for future reference.
Screwdriver safety warnings
Hold power tool by insulated gripping surfaces, when performing an operation where the fastener may contact hidden wiring or its own cord. Fasteners contacting a „live“ wire may make exposed metal parts of the power tool „live“ and could give the operator an electric shock.
Additional Safety and Working Instructions
Please only use screws specifically made for interior construction and the appropriate bit. Wear ear protectors. Exposure to noise can cause hearing loss. The dust produced when using this tool may be harmful to health. Do not inhale the dust. Wear a suitable dust protection mask. Clamp your workpiece with a clamping device. Unclamped workpieces can cause severe injury and damage. Do not use the device near flammable liquids or gases. Risk of fire and explosion in case of short circuit. Always keep the connection cable from the working area of the device. Always guide the cable back-wards, away from the device! Please turn the device immediately off when the tool used gets blocked! Do not turn the device on again when the tool is still blocked. This could cause bounce back with a high reaction moment. Deter-mine and remove the cause of the blocking of the tool used while respecting the safety instructions. The possible causes may be:
- it is tilted in the workpiece to be machined
- it has pierced through the material to be machined
- the power tool is overloaded
Mains Connection
NOTE:
Operation is only allowed with a safety switch against stray current (RCD max.
stray current of 30mA).
Connect only to single-phase AC system voltage as indicated on the rating plate. It is also possible to connect to sockets without an earthing contact as the design conforms to safety class II. Only plug-in when machine is switched off.
Maintenance
WARNING
Unplug the machine before any work on it.
Repairs and works specified in these Instructions may only be performed by
qualified authorized staff. Use only original accessories and original spare
parts. Keep the device, in particular the air vents, clean at all times. Never
spray water on the device body! Do not clean the plastics with solvents,
flammable or toxic fluids. For cleaning, use a damp cloth only.
Caution! If the power cord of the appliance gets damaged, it must be
replaced by the manufacturer or its customer service or a similarly qualified
person to avoid danger.
Only a regularly maintained and treated appliance can serve as a satisfactory
aid. Insufficient maintenance and care can lead to unforeseen accidents and
injuries. If necessary, a list of spare parts can be found at www.