ADJ 200 ENCORE BURST OUTDOOR Fixture Light User Manual

June 5, 2024
ADJ

ADJ 200 ENCORE BURST OUTDOOR Fixture Light

GENERAL INFORMATION

INTRODUCTION
This fixture has been designed to perform reliably for years when the information in this manual are followed. Please read and understand all the instructions and guidelines carefully and thoroughly before operating this unit. This manual contains important information regarding safety, installation, use, and maintenance.
UNPACKING
Each fixture has been thoroughly tested and shipped in perfect operating condition. Carefully check the outer shipping carton for signs of any damage that may have occurred during shipping. If the outer carton appears to be damaged, carefully inspect the fixture for damage and be sure all included accessories have arrived intact. In the event damage has been found and/or parts are missing, please contact our customer support team for further instructions. Please do NOT return this fixture to your dealer without first contacting customer support at the number listed below. Please do NOT discard the outer shipping carton in the trash. Please recycle whenever possible.
CUSTOMER SUPPORT: Contact ADJ Service for any product-related service and support needs. Also visit forums.adj.com with questions, comments or suggestions.
ADJ SERVICE USA – Monday – Friday 8:00am to 4:30pm PST
Voice: 800-322-6337 | Fax: 323-582-2941 | support@adj.com
ADJ SERVICE EUROPE – Monday – Friday 08:30 to 17:00 CET
Voice: +31 45 546 85 60 | Fax: +31 45 546 85 96 | support@adj.eu
REPLACEMENT PARTS please visit parts.adj.com
WARRANTY RETURNS
All returned service items, whether under warranty or not, must be freight pre-paid and accompanied by a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package. A brief description of the problem, as well as the R.A. number, must also be written down on a piece of paper and included in the shipping container. If the unit is under warranty, you must provide a copy of your proof of purchase invoice. Items returned without an R.A. number clearly marked on the outside of the package will be refused and returned at customer’s expense. You may obtain an R.A. number by contacting customer support.

LIMITED WARRANTY (USA ONLY)

  • ADJ Products, LLC hereby warrants, to the original purchaser, ADJ Products, LLC products to be free of manufacturing defects in material and workmanship for a prescribed period from the date of purchase (see specific warranty periods below). This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought.
  • For warranty service you must obtain a Return Authorization number (RA#) before sending back the prod-uct–please contact ADJ Products, LLC Service Department at 800-322-6337. Send the product only to the ADJ Products, LLC factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, ADJ Products, LLC will pay return ship-ping charges only to a designated point within the United States. If the entire instrument is sent, it must be shipped in its original package. No accessories should be shipped with the product. If any accessories are shipped with the product, ADJ Products, LLC shall have no liability whatsoever for loss of or damage to any such accessories, or for the safe return thereof.
  • This warranty is void if the serial number has been altered or removed; if the product is modified in any manner which ADJ Products, LLC concludes, after inspection, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the ADJ Products, LLC factory unless prior written authorization was issued to purchaser by ADJ Products, LLC; if the product is damaged because not properly maintained as set forth in the instruction manual.
  • This is not a service contract, and this warranty does not include maintenance, cleaning or periodic checkup. During the period specified above, ADJ Products, LLC will replace defective parts at its expense with new or refurbished parts and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of ADJ Products, LLC under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of ADJ Products, LLC. All products covered by this warranty were manufactured after August 15, 2012, and bear identifying marks to that effect.
  • ADJ Products, LLC reserves the right to make changes in design and/or improvements upon its products without any obligation to include these changes in any products theretofore manufactured. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with products described above. Except to the extent prohibited by applicable law, all implied warranties made by ADJ Products, LLC in connection with this product, including warranties of merchantability or fitness, are lim-ited in duration to the warranty period set forth above. And no warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after said period has expired. The consumer’s and/or Dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall ADJ Products, LLC be liable for any loss or damage, direct or consequential, arising out of the use of, or inability to use, this product. This warranty is the only writ-ten warranty applicable to ADJ Products, LLC Products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.

LIMITED WARRANTY PERIODS

  • Non-LED Lighting Products = 1-Year (365 Days) (Including Special Effect Lighting, Intelligent Lighting, UV lighting, Strobes, Fog Machines, Bubble Machines, Mirror Balls, Par Cans, Trussing, Lighting Stands, Power/Data Distribution, etc. excluding LED and lamps)
  • Laser Products = 1-Year (365 Days) (excluding laser diodes which have a 6-Month Limited Warranty)
  • LED Products = 2-Year (730 Days) (excluding batteries that have a 180-Day Limited Warranty) PLEASE NOTE: 2-Year (730 Days) Limited Warranty ONLY applies to products purchased within the USA.
  • StarTec Series = 1-Year (365 Days) (excluding batteries that have a 180-Day Limited Warranty)
  • ADJ DMX Controllers = 2 Year (730 Days)
  • American Audio Products = 1 Year (365 Days)

SAFETY GUIDELINES

This fixture is a sophisticated piece of electronic equipment. To guarantee smooth operation, it is important to follow all instructions and guidelines in this manual. ADJ is not responsible for injury and/or damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. Only qualified and/or certified personnel should perform installation of this fixture and only the original rigging parts (omega brackets) included with this fixture should be used for install-lation. Any modifications to the fixture and/or the included mounting hardware will void the original manufacturer’s warranty and increase the risk of damage and/or personal injury.

  • PROTECTION CLASS 1 – FIXTURE MUST BE PROPERLY GROUNDED.
  • THERE ARE NO USER-SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY REPAIRS YOURSELF, AS DOING SO WILL VOID YOUR MANUFACTURER’S WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURER’S WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.
  • DO NOT PLUG THE FIXTURE INTO A DIMMER PACK! NEVER OPEN THIS FIXTURE WHILE IN USE! DISCONNECT FIXTURE FROM POWER BEFORE SERVICING! NEVER TOUCH THE FIXTURE DURING OPERATION, AS IT MAY BE HOT! KEEP FLAMMABLE MATERIALS AWAY FROM THE FIXTURE!
  • NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE! RETINA INJURY RISK – MAY INDUCE BLINDNESS! SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
  • MAXIMUM EXTERNAL SURFACE TEMPERATURE: 185° F (85° C) MAXIMUM AMBIENT TEMPERATURE: 104° F (40° C)
  • DO NOT TOUCH the fixture housing during operation.
  • Turn OFF the power and allow approximately 15 minutes for the fixture to cool down before serving.
  • DO NOT shake fixture, avoid brute force when installing and/or operating fixture.
  • DO NOT operate the fixture if the power cord is frayed, crimped, damaged and/or if any of the power cord connectors are damaged and do not insert into the fixture securely with ease.
  • NEVER force a power cord connector into the fixture. If the power cord or any of its connectors are damaged, replace it immediately with a new one of a similar power rating.
  • DO NOT block any air ventilation slots. All fan and air inlets must remain clean and never blocked.
  • Allow approx. 6” (15cm) between the fixture and a wall for proper cooling.
  • When installing fixtures in a suspended environment, always use mounting hardware that is at least M10 x 25 mm, and always install fixtures with an appropriately rated safety cable.
  • Always disconnect fixture from the main power source before performing any type of service and/or cleaning procedure.
  • Only handle the power cord by the plug end, and never pull out the plug by tugging the wire portion of the cord.
  • During the initial operation of this fixture, light smoke or smell may emit from the interior of the fixture. This is a normal process and is caused by excess paint in the interior of the casing burning off from the heat associated with the lamp and will decrease gradually over time.
  • Consistent operational breaks will ensure fixtures will function properly for many years.
  • In the event that the fixture needs to be returned for servicing, use only the original packaging and materials to transport the fixture.

MAINTENANCE GUIDELINES

DISCONNECT POWER BEFORE PERFORMING ANY MAINTENANCE!

CLEANING
Frequent cleaning is recommended to ensure proper function, optimized light output, and extended life. The frequency of cleaning depends on the environment in which the fixture operates: damp, smoky, or particularly dirty environments can cause a greater accumulation of dirt on the fixture’s optics. Clean the external lens surface regularly with a soft cloth to avoid dirt/debris accumulation.
NEVER use alcohol, solvents, or ammonia-based cleaners.
MAINTENANCE
Regular inspections are recommended to ensure proper function and extended life. There are no user-serviceable parts inside this fixture. Please refer all other service issues to an authorized Elation service technician. Should you need any spare parts, please order genuine parts from your local Elation dealer. Please refer to the following points during routine inspections:

  • A detailed electrical check by an approved electrical engineer every three months, to make sure the circuit contacts are in good condition and prevent overheating.
  • Be sure all screws and fasteners are securely tightened at all times. Loose screws may fall out during normal operation, resulting in damage or injury as larger parts could fall.
  • Check for any deformations on the housing, color lenses, rigging hardware, and rigging points (ceiling, suspension, trussing). Deformations in the housing could allow for dust to enter the fixture. Damaged rigging points or unsecured rigging could cause the fixture to fall and seriously injure a person(s).
  • Electric power supply cables must not show any damage, material fatigue, or sediments.

NEVER remove the ground prong from the power cable.

FIXTURE OVERVIEW

ADJ 200 ENCORE BURST OUTDOOR Fixture Light-
fig1

INCLUDED ITEMS

  • Omega Bracket
  • Yoke Bracket Kit
  • Power Cable

INSTALLATION INSTRUCTIONS

IPX4 RATED
An IP-rated lighting fixture is commonly installed in outdoor environments and has been designed with an enclosure that effectively protects the ingress (entry) of external foreign objects such as dust and water. The International Protection (IP) rating system is commonly expressed as “IP” (Ingress Protection) followed by two numbers (i.e. IP20) where the numbers define the degree of protection. The first digit (Foreign Bodies Protection) indicates the extent of protection against particles entering the fixture, and the second digit (Water Protection) indicates the extent of protection against water entering the fixture.
An IPX4-rated lighting fixture has been designed for temporary outdoor environments. It has NOT been tested to protect against the ingress of dust (X) but has been tested to protect from splash of water in any direction (4).
PERMANENT OUTDOOR AND/OR MARINE/COASTAL INSTALLATIONS
Please note although this fixture is IP rated, this fixture is NOT suitable for permanent outdoor and/or marine environment installations. Installing this fixture in permanent outdoor and/or marine environment installation may cause corrosion and/or excessive wear to the interior and/or exterior components of the fixture. Damages and/or performance issues resulting from installation in a permanent outdoor and/or marine environment installation will void the manufacturer’s warranty and will NOT be subject to any warranty claims and/or repairs.

  • FLAMMABLE MATERIAL WARNING
    Keep fixture at least 5.0 feet (1.5m) away from flammable material and/or pyrotechnics.

  • ELECTRICAL CONNECTIONS
    A qualified electrician should be used for all electrical connections and/or installations.

  • ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH A NON-CONDUCTIVE DIELECTRIC GREASE (AVAILABLE AT MOST ELECTRICAL SUPPLIERS) TO PREVENT WATER INGRESS/CONDENSATION AND/OR CORROSION.

  • USE CAUTION WHEN POWER LINKING FIXTURES OF DIFFERING MODEL TYPES, AS THE POWER CONSUMPTION OF THESE DIFFERING MODELS MAY EXCEED THE MAXIMUM POWER OUTPUT RATING OF THIS FIXTURE. CHECK THE SILK SCREEN FOR MAX AMPERAGE.

DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO!

Fixtures MUST be installed following all local, national, and country commercial electrical and construction codes and regulations. Before rigging/mounting a single fixture or multiple interconnected fixtures to any metal truss/structure or placing the fixture(s) on any surface, a professional equipment installer MUST be consulted to determine if the metal truss/structure or surface is properly certified to safely hold the combined weight of the fixture(s), clamps, cables, and accessories. The maximum ambient operating temperature is 104°F. (40°C) Fixture(s) should be installed in areas outside walking paths, seating areas, or away from areas where unauthorized personnel might reach the fixture by hand. NEVER stand directly below the fixture(s) when rigging, removing or servicing. Overhead fixture installation must always be secured with a secondary safety attachment, such as an appropriately rated safety cable that can hold 10 times the weight of the fixture. Allow approximately 15 minutes for the fixture to cool down before serving.

TO MAINTAIN IP RATING INTEGRITY, ALL UNUSED CONNECTION RUBBER CAPS MUST BE SEALED.ADJ 200 ENCORE BURST OUTDOOR Fixture Light-fig2

OVERHEAD RIGGING
Overhead rigging requires extensive experience, including calculating working load limits, installation material being used, and periodic safety inspection of all installation material and the fixture, among other skills. If you lack these qualifications, DO NOT attempt the installation yourself. Improper installation can result in bodily injury and property damage.
OMEGA BRACKET
The included Omega Bracket can be attached to either of the long edges (for a “horizontal” orientation). The best edge to attach the bracket to will depend on the desired installation. Follow the installation steps below.

OMEGA BRACKET MUST BE USED WHEN CONNECTING FIXTURES TOGETHER!

  1. Attach the Omega Bracket to the fixture using 2 of the 4 included interlocking pins.
  2. To remove the interlocking pins, push in the spring-loaded pin, and turn clockwise or counter-clockwise until it releases from the fixture.
  3. Slide the bracket into the alignment holes on the fixture.
  4. Insert 2 interlocking pins into the fixture holes, making sure the pins go completely through the fixture and into the bracket. With the pins completely inserted, push the pins towards the fixture and turn clockwise or counter-clockwise to lock them into place.
  5. Confirm both pins and the bracket are secure before mounting the fixture with an appropriately rated professional grade rigging clamp. ADJ 200 ENCORE BURST OUTDOOR Fixture Light-fig3

YOKE BRACKET KIT
The included Yoke Bracket Kit can be attached to the fixture using the included hardware. Follow the installation steps below.

  1. Attach the Yoke Bracket to the fixture using the included hardware.
  2. Adjust the bracket into the desired position, then tighten the adjustment knobs securely.
  3. Mount the fixture with an appropriately rated professional-grade rigging clamp. ADJ 200 ENCORE BURST OUTDOOR Fixture Light-fig4

CONNECTING FIXTURES TOGETHER
The fixture includes a unique interlocking system that allows multiple fixtures to be connected together horizontally, using the 4 included spring- loaded interlocking pins on each fixture. Follow the installation steps below.

OMEGA BRACKET MUST BE USED WHEN CONNECTING FIXTURES TOGETHER!

  1. Attach the Omega Bracket to the first fixture as described on the previous page.
  2. Push out the spring-loaded bracket on the top and bottom edges of each fixture, then slide fixtures together and align the holes on both spring-loaded brackets on both fixtures.
  3. Insert interlocking pins into the fixture holes, pushing pins completely through and turning clockwise or counter-clockwise to lock into place.
  4. Repeat steps 5 and 6 to attach additional fixtures horizontally.
  5. Confirm Omega Bracket on top fixture. Each fixture must be mounted with its own appropriately rated professional grade rigging clamp. ADJ 200 ENCORE BURST OUTDOOR Fixture Light-fig5

MAXIMUM NUMBER OF CONNECTING FIXTURES = 10
Each set of 10 fixtures must be attached to a structure that can support 10x the total weight of the entire assembly (10 x combined weight of 10 fixtures and any associated hardware and accessories). The first fixture in the chain must be attached to the structure using the Omega Bracket and an appropriately rated professional grade rigging clamp.

OMEGA BRACKET MUST BE USED WHEN CONNECTING FIXTURES TOGETHER!ADJ 200
ENCORE BURST OUTDOOR Fixture Light-fig6

SAFETY CABLES
Each fixture includes a Safety Cable attachment loop on the back. All fixtures installed in an overhead configuration MUST always be secured with a dedicated secondary safety attachment, such as an appropriately rated safety cable that can hold 10 times the weight of the fixture.

  • WHEN INSTALLING THE FIXTURE IN A SUSPENDED ENVIRONMENT, ALWAYS ATTACH AN INDEPENDENT SAFETY CABLE BETWEEN THE TRUSS/STRUC-TURE AND THE FIXTURE IN ORDER TO ENSURE THAT THE FIXTURE WILL NOT FALL IF THE CLAMP OR INTERLOCKING PINS FAIL!
  • NEVER DAISY CHAIN MULTIPLE SAFETY CABLES TOGETHER BETWEEN MULTIPLE FIXTURES! EACH FIXTURE MUST HAVE ITS OWN INDEPENDENT SAFETY CABLE, AS SHOWN IN THE IMAGE BELOW! ADJ 200 ENCORE BURST OUTDOOR Fixture Light-fig7

ADJUSTING LED LENS POSITION DEGREE
The LED lens position can easily be adjusted manually from the default 0-degree position to 7.5+ or 15+ degrees (UP) and -7.5 and -15.0 degrees (DOWN). Simply push the LED lens array either UP or DOWN by hand until the desired angle is achieved. The LED lens array movement can be adjusted by loosening or tightening the small screw on the side of the fixture using a matching size hex key (not included). ADJ 200 ENCORE BURST OUTDOOR Fixture
Light-fig8

SYSTEM MENU
The fixture includes an easy-to-navigate system menu where fixture settings can be adjusted via the LCD control panel located on the back of the fixture. (see image below) To access the system menu press and hold the MENU button for 3 seconds. The LCD Menu Control Display will shut OFF automatically about 1 minute from the last button press.

MENU Select the program function
DOWN Go forward in the selected function
UP Go backward in the selected function
ENTER Confirm selected function

ADJ 200 ENCORE BURST OUTDOOR Fixture Light-fig9

Address: DMX-512 Address Setting.
Select “Add,” then press the ENTER button. When the display begins to blink, use the DOWN and UP buttons to change the DMX-512 address (001-512). Once the address has been selected, press the ENTER button to confirm, or press the MENU button to exit without making any change. The system will return to the main menu after 8 seconds of inactivity.
Chen: Channel Mode.
Select “ChNd,” then press the ENTER button. Use the DOWN and UP buttons to select the channel mode from the following options:

  • 1-Channel Mode
  • 2-Channel Mode
  • 2A-Channel Mode
  • 3-Channel Mode
  • 4-Channel Mode
  • 6-Channel Mode

Once you have made your selection, press the ENTER button to confirm, or exit to the main menu without making any changes by pressing the MENU button. The system will return to the main menu after 8 seconds of inactivity.

dINd: Dimmer Curve.
Select “dINd,” then press the ENTER button. Use the DOWN and UP buttons to select from the fol-lowing dimmer curves:

  • Standard
  • Stage
  • TV
  • Architec
  • Theatre
  • Stage2

Once you have made you selection, press the ENTER button to confirm, or press the MENU but-ton to exit without making any changes. The system will return to the main menu after 8 seconds of inactivity.

Und: Tungsten Filament Effect.
Select “Und,” then press the ENTER button. Use the DOWN and UP buttons to select “on” or “off.” Once you have made your selection, press the ENTER button to confirm, or press MENU to exit without making any changes.
dNSt: DMX State.
Select “dNSt,” then press the ENTER button. Use the DOWN and UP buttons to select from the following options:

  • “bLNd”: Blackout
  • “HoLd”: Hold last state
  • “NAnd”: Manual mode

Once you have made your selection, press the ENTER button to confirm, or press MENU to exit without making any changes.

  • faq: Dimming Frequency.
    Select “FAeq,” then press the ENTER button. Use the DOWN and UP buttons to scroll through the available frequency settings (900 Hz, 1000 Hz, 1100 Hz, 1200 Hz, 1300 Hz, 1400 Hz, 1500 Hz, 2500 Hz, 4000 Hz, 5000 Hz, 10000 Hz, 15000 Hz, 20000 Hz, or 25000 Hz). Press ENTER to confirm your selection, or press MENU to exit without making changes.

  • Gann: Gamma Correction.
    Select “Gann,” and press the ENTER button. Use the DOWN and UP buttons to scross through the available gamma correction settings (No, 2.0, 2.2, 2.4, 2.6, or 2.8). Press ENTER to confirm your selection, or press MENU to exit without making changes. Please note that the 2.6 gamma cor-rection setting was added with software update version 1.3.

  • Disp: Display Invert.
    Select “dISP,” and press the ENTER button. Use the DOWN and UP buttons to scroll between
    “Disp” (normal orientation) or “dSIP” (inverted orientation). Press ENTER to confirm your selection, or press MENU to exit without making changes.

  • NAND: Manual Mode.
    Select “NAnd,” and press the ENTER button. Use the DOWN and UP buttons to select the bright-ness (dxxx) or strobe (Sxxx). Please note that strobe is only available when the device is set to 4-Channel Mode or 6-Channel Mode. Press ENTER to confirm your selection, then use the DOWN and UP buttons to adjust the value between 000 – 255. Press ENTER again to confirm your selection, or press MENU to exit without making changes.

  • teSt: Auto Test.
    Select “teSt,” and press the ENTER button. The unit will now run a built-in self-test program. Press the MENU button to return to the main menu, or wait ten seconds for the system to automatically return to the main menu.

  • tENP: Temperature Display.
    Select “ten,” and press the ENTER button. The device will now display the current temperature reading of the device. Press MENU to return to the main menu.

  • Fri: Fixture Hours.
    Select “FhrS,” and press the ENTER button. The device will now display the number of run time hours that have been logged. Press MENU to return to the main menu.

  • ver: Software Version.
    Select “ver,” and press the ENTER button. The device will now display the current software version of the unit. Press the MENU button to return to the main menu.

  • dEF: Factory Setting.
    Select “dEF,” and press the ENTER button. Use the DOWN and UP buttons to scroll to either “YeS” to restore the device to factory settings, or “no” to exit without making changes. Press the ENTER button to confirm your selection.

DIMMING CURVEADJ 200 ENCORE BURST OUTDOOR Fixture Light-
fig10

The fixture includes 6 different dimming curve modes which can selected from either the system menu or via DMX. The graph below provides details on each dimming curve mode.

DMX CHANNEL FUNCTIONS AND VALUES

CHANNEL| DMX VALUE|

FUNCTION

---|---|---
1CH| 2CH| 2ACH| 3CH| 4CH| 6CH
1| 1| | 1| 1| | 000 – 255| Master Dimmer – Left & Right Pixels, 0-100%
| 2| | 2| 2| | 000 – 255| Dimmer Fine – Left & Right Pixels
| | 1| | | 1| 000 – 255| Master Dimmer – Left Pixel, 0-100%
| | 2| | | 2| 000 – 255| Master Dimmer – Right Pixel, 0-100%
| | | | | 4| 000 – 255| Master Dimmer / Intensity, 0-100%
| | | | | 5| 000 – 255| Master Dimmer / Intensity Fine
| | | |

3

|

3

| | Shutter / Strobe
000 – 031| LED Off
032 – 063| LED On
064 – 095| Strobe Effect, slow to fast
096 – 127| LED On
128 – 159| Strobe Pulse Effect in Sequences, slow to fast
160 – 191| LED On
192 – 223| Random Strobe Effect, slow to fast
224 – 255| LED On
| | |

3

|

4

|

6

| | Dimming Modes
000 – 020| Standard
021 – 040| Stage
041 – 060| TV
061 – 080| Architectural
081 – 100| Theater
101 – 120| Stage 2
121 – 255| Default to Unit Setting

SPECIFICATIONS

  • Voltage: 100-240V / 50/60Hz
  • LEDs: x2 110W CREE COB LEDs
  • Color Temperature: 2700K (1200K Tungsten Mode)
  • IP Rating: IPX4
  • Working Position: Any Safe Working Position
  • Power Draw: 235W
  • Power Linking: 4 Fixtures Max @120V | 8 Fixtures Max @240V
  • Fuse: 1A
  • DMX Channels: 6 DMX Channel Modes 1 / 2 / 2A / 3 / 4 / 6
  • Connections: 5pin DMX and Locking Power Cable In/Out
  • Control: RDM (Remote Device Management)
  • Weight: 15 lbs. (6.8kg)
  • Dimensions (LxWxH): 15.7” (400mm) x 7.9” (200.5mm) x 8.5” (215.5mm)
  • Dimensions w/Bracket (LxWxH): 15.7” (400mm) x 7.9” (200.5mm) x 10.4” (264mm)
  • Dimensions w/Yoke (LxWxH): 19.8” (503mm) x 7.9” (200.5mm) x 12.8” (325.3mm)
  • Warranty: 2 Years (730 Days)

FCC STATEMENT

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC RADIO FREQUENCY INTERFERENCE WARNINGS & INSTRUCTIONS
This product has been tested and found to comply with the limits as per Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This device uses and can radiate radio frequency energy and, if not installed and used in accordance with the included instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause harmful interference to radio or television reception, which can be determined by turning the device off and on, the user is encouraged to try to correct the interference by one or more of the following methods:

  • Reorient or relocate the device.
  • Increase the separation between the device and the receiver.
  • Connect the device to an electrical outlet on a circuit different from which the radio receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

DIMENSIONAL DRAWINGSADJ 200 ENCORE BURST OUTDOOR Fixture Light-
fig11 ADJ 200 ENCORE BURST OUTDOOR Fixture Light-
fig12

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals