STORCH AirClean Extraction Fan 4200 PRO User Manual
- June 5, 2024
- STORCH
Table of Contents
STORCH AirClean Extraction Fan 4200 PRO User Manual
Scope of delivery
AirClean extraction fan, reusable dust bag and clamp, operating hours counter, user‘s Manual.
Technical specifications
- Max. air flow 4,200 m3/h
- Pressure 550 Pa
- Rating 230V / 50Hz
- Fuse 2,9 A
- Height x Width x Length 52 x 40 x 53 cm
- Weight 17,5 kg
- Motor power 0,62 kW
- Noise level at 4 m distance 78 dB (A)
All information is without guarantee! Subject to technical modifications and errors!
Intended use
The extractor fan is particularly suitable for extracting and filtering fine airborne dust particles and spray mist to improve the condition of the ambient air during renovation and restoration procedures, to aid building drying processes and to aerate and ventilate rooms.
Extraction and filtering of dust and spray mist
The dust bag is mounted at the exhaust side of the extractor fan to absorb the
airborne dust particles and spray mist generated during renovation and
restoration procedures. The exhaust side is identified by the arrow on the
device. The dust bag is attached to the exhaust side with a clamp. The dust
bag is 3 metres long. It should be ensured that it is able to fully expand to
guarantee optimal filtration of the dust, dirt and spray mist particles.
Optimal extraction for large scale renovation and restoration procedures can
be achieved if the windows in the room remain closed and the suction port of
the AirClean unit is placed in the entrance door. Seal the door frame above
and beside the device with film. Doing this will generate negative pressure in
the room.
Using the reusable filter bag (included)
Please make sure the filter bag is cleaned on a regular basis (shake / wash
and dry). A clogged filter will reduce the suction power of the AirRClean
unit. For example, directly next to the radiator when spray painting
radiators, or in the door frame when sanding ceilings.
You can read off the elapsed operating hours from the operating hours counter.
Use for drying buildings
When drying builds deploy at least one extraction fan per room. Make sure that the outlet side faces the wet surfaces.
Use of the extraction fan increases evaporation in the room.
This increases the humidity and drying becomes slower. For this reason, we
recommend additionally deploying a building dryer (air dehumidifier), e. g.
the STORCH HighDry 300 Building Dryer. (Art. No. 61 53 00). To accelerate
drying, seal off the area to be dried from the rest of the building. For best
possible dehumidifying performance, the ambient temperature should be between
20° C and 27° C.
Operation
Always use an earthed power supply at 230 V / 50Hz to operate the extraction fan. If you will be using the extraction fan for extracting and filtering dust and spray mist, make sure you use the clamp to attach the dust bag included with the device to the extraction side (direction of arrow). Switch on the device and check that it is operating properly. Do not move or transport the extraction fan during operations. Do not reach into, or insert objects into, the device.
Service/Maintenance
Caution
Always unplug the power plug before commencing servicing or maintenance work.
Visual check : Check the power cable, housing, ventilator covers and motor housing regularly for signs of damage.
Clean the air intake : Clean the air intake: Remove any soiling that has built up at the air intake. Use compressed air to remove fibrous material, dust and fan blades from the fan wheel, motor and side covers. Never clean the extraction fan with a water jet or a pressure washer.
Motor bearings : The bearings on the device are permanently lubricated. Do not oil or grease.
Safety precautions
The device possesses a voltage range which can pose an electrical hazard to humans and animals. It should only be opened and/or disassembled by authorised persons.
Keep away from children:
Do not let children play with or in the vicinity of the device.
Electrical connection:
The extraction fan is designed for use at 230V/50 Hz. Use an earthed plug!
Make sure that the wall sockets being used are equipped with ground fault
circuit interrupters.
Protect the power cable against damage:
Never operate the device with a damaged power cable. If the power cable is
damaged, it must be replaced by a cable of the same type and rating.
Extension cables:
Use only approved extension cables!
Handle with care:
Do not drop or throw the device as this can cause damage to its components or
wiring.
Work on a firm surface:
Always set up the device on a firm and flat surface.
Troubleshooting
Warning
Make sure you have unplugged the mains plug before performing the following maintenance tasks.
Column 3:
B – User, AST – authorised service centre
Error | Cause | by | Solution |
---|---|---|---|
Motor not running | Mains plug not plugged in | B | Plug in device, check |
fuse
Switch not actuated| B| Switch on device
Fan wheel blocked| B| Pull mains plug, remove block
Air inlet or outlet blocked| B| Switch off, unplug and allow to cool;
then remove block
Switch defective| AST| Fit a new switch
Loose wiring| AST| Check wiring and tighten connectors
Motor running, fan wheel not turning smoothly or scraping| A heavy blow has
deformed the motor mounting, the fan wheel is jammed| AST| Remove motor,
repair deformed motor mounting replace if necessary
The motor has slipped out of its mounting, the fan wheel is jammed| AST| Refit
motor, fitting it correctly in the mounting
Device vibrating excessively| Dirt on fan wheel| B| Clean fan wheel
Fan wheel imbalanced| AST| Balance or replace fan wheel
Fan wheel deformed| AST| Replace fan wheel
Motor shaft deformed| AST| Replace motor
Secure during transport:
When transporting in vehicles, secure the device against slipping. Never move the appliance while it is switched on.
Keep dry:
Never operate the device in puddles or in water. Do not store or operate
outdoors. If the wiring or any part of the device becomes wet, dry the device
thoroughly before using. Protect against spray water.
Keep air vents free:
Do not cover or block the air inlets or outlets.
Do not use speed controller:
To reduce the risk of fire or electric shock, never operate the extraction fan
with an electronic speed controller.
Fire hazard : never run the appliance in areas with open fire or heat sources. Do not use or store the device in area where flammable vapors, solvents, thinners or petrol are stored.
Aeration and ventilation
For aeration and ventilation purposes set up the extraction fan as required
with the outlet side (arrow direction / ventilation), or the inlet side
(aeration) on a flat, firm surface in the open door or open window. The
discharged air must not exceed a temperature of 60° C.
In small rooms place the extraction fan in the door frame in a way that allows the dust bag to spread out in the adjacent space. Depending on the purpose and room size, it may be necessary to position the extraction fan properly to ensure best possible extraction performance.
Detailed drawings
- Plastic housing
- Motor
- Fan wheel
- Hose fitting
- Complete operating element
- Complete operating element
- Power cable
- Condenser
Warranty
A legal warranty period of twelve months from the date of purchase/date of invoice applies to our tools for commercial customers.
Claims
If you wish to claim under our warranty or guarantee, please return the
complete machine and your invoice to our logistics centre in Berka, postage
paid, or send it to one of our authorised service centres. We request that you
contact us beforehand by calling our free STORCH service hotline on 0800 7 86
72 47.
Warranty entitlement
Claims can only be accepted for material defects or manufacturing errors, and
only assuming proper use of the appliance. Wear parts are not covered by
warranty claims. All claims shall become void in the event of installation of
third party components, improper handling and storage, as well as in the event
of obvious disregard of the operating instructions.
Performing repairs
All repairs must be conducted on our premises or by an authorised STORCH
service centre.
Disposal
End-of-life devices must not be disposed of as domestic waste. Please take them to a suitable collection point or hand over the end-oflife device to your specialist dealer.
EC Declaration of Conformity
Name / Address of issuer : STORCH Malerwerkzeuge & Profigeräte GmbH Platz
der Republik 6
D-42107 Wuppertal
We herewith declare:
that the following machine complies with the fundamental health and safety
requirements of the EC Directives in terms of its design, construction and
version we have brought into circulation.
This warranty loses its validity in case of unauthorised modification of the tool.
Designation of the machine : AirClean Extraction Fan 4200 PRO
Machine Type : Axial Fans
Item number : 61 45 50
Applied EC directives
Machinery Directive : 2006 / 42 / EC
EC- Electromagnetic Compatibility
Directive : 2014 / 30 / EC
RoHS Directive : 2011 / 65 / EC
Applied harmonised standards
ISO 12100:2010 ISO 12100 : 2010-11
DIN EN ISO 12100-1: 2004-04 DIN EN 60204-1 (VDE 0113-1):2007-06
Applied national standards and technical specifications
EN ISO 12100
EN 61000-6-3
EN 61000-6-2
Representative authorised to compile the technical documentation:
STORCH Malerwerkzeuge & Profigeräte GmbH
Platz der Republik 6
D-42107 Wuppertal
Germany
Jörg Heinemann
– Managing Director –
Wuppertal, 04-2016
Responsibility of the operating company
Note:
The operating company must ensure the following:
- The device must only be used in the intended manner.
- The device must be maintained in accordance with the specifications in this operating manual.
- The device must only be operated in accordance with local guidelines and occupational health and safety regulations.
- All precautions are taken to avoid dangers arising from the device.
- All precautions are taken for first aid care and fire fighting
Organisation/personnel
Operators
Note:
- Before starting to use the device, the operator must have read and understood the operating manual.
- Only authorised and trained operators must have access to the device in order to operate it.
- The operating manual must be available to the operator at all times.
- The operator must not be under the influence of alcohol, drugs or medication.
- Children, performance-impaired persons, and pregnant women are not allowed to operate the device.
STORCH service
Telefon : +49 202 49 20 112
Fax : +49 202 49 20 111
References
Read User Manual Online (PDF format)