QUALITY SPACE HEATERS Installation &
Control Guide for
Sun-Zone Radiant Heaters for SL Wireless Controllers
Models
HE6502SL 2kW, HE6503SL 3kW
All electrical appliances produced by the Company are guaranteed for one year
against faulty materials or workmanship. This applies only if the appliance
has been used for purposes in accordance with the instructions provided and
has not been connected to an unsuitable electricity supply, or subject to
misuse, neglect, damage or modified or repaired by any person not authorized
by us. This guarantee is offered to you as an extra benefit and does not
affect your legal rights.
The correct electricity supply voltage is shown on the rating label attached
to the appliance.
Reasonable care has been taken to ensure that this guide is accurate at the
time of printing. In the interest of progress the Company reserve the right to
vary specifications from time to time without notice.
Overvie0w
Please read this guide carefully and retain for future use and maintenance. This appliance has been designed and manufactured to the highest international standards, however, care must be taken for optimal results and safety. This appliance also meets the requirements of EU Directive 2004/106/ EC for EMC and 2009/125/EC Directive.
Safety & Care
The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Warning
- Do NOT site the appliance in a corner.
- Do NOT use the appliance in workshops or rooms where excessive dust is generated or present.
- Do NOT touch the outlet grille when the appliance is in use.
- Do NOT cover or restrict any aperture of the appliance when in use.
- Do NOT use the appliance if damaged.
- Do NOT leave the appliance unattended.
- Do NOT use the heater in hazardous areas.
Cleaning
Always disconnect the heater from the mains before cleaning. The heater should not require any maintenance, but it is strongly advised that is be kept clean. An occasional wipe over with a soft cloth is all that should be necessary.
- Do NOT use metal or furniture polish on any part of the heater.
- Do NOT touch the heater with wet hands or in any way bring water into contact with it.
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
If Your Heater Does Not Work
- Check that power is available to the heater. The LED light on the SL receiver should be illuminated
- Check that the fuse in the spur unit has not blown. This can be done by replacing the fuse with another suitable fuse.
- Check if the heater is paired with the SL controller Should none of the above remedies work, then telephone the helpline number shown in these instructions (UK ONLY). Do not attempt to repair the heater.
Connection to the Main Supply
Electrical installation should be carried out by a competent installer,
preferably registered with NICEIC in accordance with the 17 edition of the IEE
Wiring Regulations, (BS.7671), and any relevant Local Authority Bye-Laws. This
heater is fitted with a 3-core mains supply cable and must be permanently
connected to the electricity supply via a double pole switch having 3mm gap on
each pole. There are no exceptions. A switched Fused Connection unit to
BS.1363. Part 4 is a recommended mains supply connection accessory to ensure
compliance with safety requirements applicable to the fixed-wiring
installation.
Note: When switched on for the first time the appliance may emit a slight
smell.
WARNING: This appliance must be earthed. When refitting the lid care must
be taken to align the light pipe on the lid with the indicator light.
Spare Parts
2 kW element for HE6502SL | – HE6522 |
---|---|
3 kW element for HE6503SL | – HE6523 |
Pair of Mounting brackets | – HE6524 |
Element replacement.
Ensure the mains supply is off, remove the terminal cover and disconnect the
element leads from the terminal block.
Slide off the wire guard and remove the screw holding the element support
nearest the terminal block. Straighten the support clips at the back of the
reflector and push out the failed element. Fit new elements in reverse order.
Assembly
Sun-Zone provides a wide beam distribution of radiant heat. Each unit is supplied complete with a fitted metal sheathed wire element, wire guard and a pair of mounting brackets.
Installation
The Sun-Zone must not be mounted close to a wall or ceiling. The minimum distances are shown below in figure 1.
The Sun-Zone should be mounted at a minimum height of 2.1m from the floor.
The Sun-Zone can be wall or ceiling mounted, it can also be suspended on
chains or conduits as shown in Figure 2.
Fixing centers
Part No. | Bracket/Chain | Conduit |
---|---|---|
HE6502SL | 1170mm | 1250mm |
HE6503SL | 1570mm | 1660mm |
Special Note
Sun-Zone uses a metal sheathed wire element and it is a characteristic of this element that a small amount of moisture can be absorbed from the atmosphere during storage or even after installation if not in regular use. It is possible that the amount of moisture absorbed could decrease the earth leakage resistance with spurious operation of the current sensitive earth leakage circuit breaker recommend for the Sun-Zone circuit. Should such a condition occur, disconnect the heater and run for a few minutes in the circuit without the earth leakage protection, this will drive off any offending moisture. Return the circuit to its correct state with the RCCB connected. This must only be carried out by a competent electrician.
SL Receiver Installation
The heater is supplied with the SL wireless receiver pre-wired. The cable length is approximately 0.9m. The controller should be screwed to the wall with 2x number 4 or 5 screws and suitable wall plugs. Care should be taken when installing the receiver. It must not be positioned above, behind or below the heater. Ideal position is on the side, a minimum of 250mm from the heater. When the heater is suspended from the ceiling, the SL receiver should be installed on the ceiling as far as possible from the heater to avoid damaging the electronic components when connecting the main cable to the receiver. If the cable between the heater and the SL receiver needs replacing or extending, the same 2.5mm high-temperature flexible cable must be used.
Operation
When the appliance is connected to the mains supply, the LED indicator will light up green, showing that the power is available to the unit. When the heat output has been enabled by a wireless controller, the LED indicator light will turn red. This heater can only be used when connected to an SL wireless controller. Each SL controller can control any number of heaters providing they are within the RF range. Please refer to the SL controller installation and control guide for full operational details.
CUSTOMER HELPLINE
Should you need any advice on the use of your new Consort product, please
contact our Helpline:
Consort Equipment Products Limited
Thornton Industrial Estate, Milford Haven, Pembrokeshire, SA73 2RT
Tel: 01646 692172 Fax: 01646 695195
Email: technical@consortepl.com Web:
www.consortepl.com
Operation hours: Mon to Thu 8.30 am to 4.30 pm | Fri 8.30 am to 3.30 pm
BS EN ISO 9001 Registered Company No FM12671
38000046 Iss 03
Documents / Resources
|
Consort HE6502SL 2kW/HE6503SL 3kW Sun-Zone Radiant
Heaters
[pdf] User Guide
HE6502SL 2kW, HE6503SL 3kW, Sun-Zone Radiant Heaters, HE6503SL 3kW Sun-Zone
Radiant Heaters, Radiant Heaters, Heaters
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>