LST800ERF Quality Space Heaters

All electrical appliances produced by the Company are guaranteed for one year against faulty materials or workmanship. This applies only if the appliance has been used for purposes in accordance with the instructions provided and has not been connected to an unsuitable electricity supply, or subject to misuse, neglect, damage, or modified or repaired by any person not authorized by us. This guarantee is offered to you as an extra benefit and does not affect your legal rights.
The correct electricity supply voltage is shown on the rating label attached to the appliance.
Reasonable care has been taken to ensure that this guide is accurate at the time of printing. In the interest of progress the Company reserve the right to vary specifications from time to time without notice.

General safety

Our Low Surface Temperature heaters have been designed and built to the NHS requirement for safe surface temperatures which is that no surface which can be touched by the user will be more than 43 degrees C (at a room temperature of 21 degrees C.) This means that our Low Surface Temperature heaters outperform the European Standard by a significant margin. The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

Warning

  • Do NOT site the appliance in a corner.
  • Do NOT handle the appliance with wet hands.
  • Do NOT use the appliance in workshops or rooms where excessive dust is generated or present.
  • Ensure that nothing is pushed into the air outlet of this appliance.
  • Do NOT touch the outlet grille when the appliance is in use.
  • Do NOT cover or restrict the appliance when in use.
  • Do NOT use the appliance if damaged.
  • Do NOT leave the appliance unattended where young children are present.

Connection to the Main Supply

Electrical installation should be carried out by a competent installer, preferably registered with NICEIC (National Inspection Council for Electrical Installation Contracting) in accordance with the 17 edition of the Wiring Regulations, (BS.7671), and any relevant Local Authority Bye-Laws.
This heater is fitted with a 3-core mains supply cable and must be permanently connected to the electricity supply via a double pole switch having 3mm gap on each pole. There
are no exceptions.
A switched Fused Connection unit to BS.1363. Part 4 is a recommended mains supply connection accessory to ensure compliance with safety requirements applicable to the fixed-wiring installation.
Note: When switched on for the first time the appliance may emit a slight smell. This is purely the evaporation of a fluid used in the manufacturing process.
WARNING: This appliance must be earthed.

Thermally Operated Cut-Out

The appliance is fitted with a thermally operated cut-out (TOC). This is a safety device, which switches the heater off if, for any reason, the appliance overheats. The TOC can
only be reset after the appliance has cooled down. In order to re-set the TOC, proceed as follows:

  • Switch off the appliance and leave for approximately 10 minutes.
  • Switch the appliance back on and the TOC will re-set.
  • Ensure that the appliance is functioning correctly. If the TOC control operates again, the appliance should be checked by a competent electrician.

The heater carries a ‘Do Not Cover’ label to warn the user that if the appliance is covered, there is a risk of overheating.

Cleaning

Always disconnect the heater from the mains before cleaning. The heater should not require any maintenance, but it is strongly advised that it is kept clean. An occasional
wipe-over with a soft cloth is all that should be necessary.

  • Do NOT use metal or furniture polish on any part of the heater.
  • Do NOT touch the heater with wet hands or in any way bring water into contact with it.

If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.

Mounting

To wall mount, the wall bracket supplied must be used. Remove the wall bracket from the heater, with the chains attached, by removing the 2 securing screws from the top of the rear panel.
Fix the wall bracket to the wall using 4 screws. Fig 1: Present the heater to the bracket Fig 2: Locate the heater onto the bottom lugs via the 2 slots in the rear panel. Hinge the heater upwards and reattach the chain assembly, then move the heater to the upright position. The link plates should slide under the slotted bracket lip.
Fig 3: Tighten both retaining screws.
The heater must not be located immediately below a fixed socket outlet.

Installation

CONSORT LST800ERF Quality Space Heaters - 1

Rear &Side View

| MILLIMETRES
---|---
WATTS| A| B| C| D/E
LSTE500E| 500| 830| 430| 616| 107
LSTE800E| 800| 1183| 430| 952| 115

CONSORT LST800ERF Quality Space Heaters - fig1

CONSORT LST800ERF Quality Space Heaters - 2

  1. Basic Operation
    Before you can use the LSTE, it has to be activated by pressing any control button. The LCD backlight will turn on. To operate any control button, press it within 2 seconds of activation.

  2. Time and day setting
    -Press and hold the TIME button for 5 seconds.
    Minutes are flashing – use TEMP and MODE buttons to set minutes.
    -Press the TIME button
    Hours are flashing – use TEMP and MODE buttons to set hours.
    -Press the TIME button
    The day is flashing – use the TEMP and MODE buttons to set Day. Once you are happy with the settings, press ‘Time’ to return to the main screen.

  3. Selecting the operating mode
    LSTE has 4 operating modes:
    BOOST, MANUAL, SET BACK, PROGRAM.
    Each mode can be selected by pressing the MODE button to cycle through the options. The cycle sequence will always start with BOOST mode followed by MANUAL,
    SET BACK and PROGRAM.

  4. BOOST – 15 minutes
    The boost feature increases the room temperature for 15 minutes.
    1. Use TEMP and MODE to set the temperature.
    To amend the set temperature when in Boost mode, simply activate the display by pressing any button. Press TEMP, then use TEMP and MODE to change the temperature. Once the temperature is set, you can leave the display to return to the main screen and the settings will be saved. After 15 minutes, the LSTE will return to the previous operating mode.

  5. MAN – Manual Mode
    In manual mode, the heater maintains the set temperature.
    1. Use TEMP and MODE to set the temperature.
    To amend the set temperature when in Manual mode, simply activate the display by pressing any button. Press TEMP, then use TEMP and MODE to change the temperature. Once the temperature is set, leave the display to return to the main screen and the settings will be saved.

  6. SETB – Reduction in programmed temperature
    In the setback (ECONOMY) mode, LSTE lowers all temperatures in the 7-day program by a set value. You can set by how much to lower the program temperatures in SETB mode by simply activating the display, pressing TEMP, and using TEMP and MODE to set the new value.
    The display will first show the temperature difference and after 2 seconds the new set temperature.

  7. PROG – Automatic time mode
    In this mode, the LSTE will follow the week’s time/temperature program.
    You can temporarily override the temperature in PROG mode by simply activating the display and using the TEMP and MODE buttons to set the new temperature. The new set temperature will be then maintained until the next program step.

  8. Set a 7-day program
    An example of one day program on LSTE
    CONSORT LST800ERF Quality Space Heaters - 3
    Logic diagram for setting program on LSTECONSORT LST800ERF Quality Space
Heaters - 4

  9. Press and hold PROG for 5 seconds to enter the time setting.

  10. The day will be flashing.

  11. Use TEMP and MODE to navigate day, press PROG to select a day.

  12. PROG 1 will be flashing. Use TEMP and MODE to navigate the program, and use PROG to select the program.

  13. The minutes will be flashing.

  14. To set minutes, use TEMP and MODE to change minutes, and press PROG to set the minutes.

  15. The hour will be flashing

  16. To set the hour, use TEMP and MODE to change the hour, and press PROG to set the hour.

  17. The temperature will be flashing.

  18. To set temperature, use TEMP and MODE to change temperature, press PROG to set temperature.
    To add another program repeat steps 2-10.
    The LSTE has a 7-day timer with up to 6 programming steps available for each day. In the programming, you can set a start time and a temperature for each program. Each program has to be used.

  19. Advance mode
    Press PROG from PROG mode to bring forward the next program. To clear advance mode, press PROG.

  20. Heat symbol on the display
    Every time there is a demand for heat, the display will show the heart icon.
    – full heat output

  21. Keys locking
    Press and hold TIME and TEMP together for 5 seconds. The display will show symbols. Repeat the step to unlock.

  22. Open Window Detection Ensuring you don’t waste energy on heating the outside world, the heater is equipped with optional open/closed window detection. The heater recognizes sudden drops in temperature when a window or a door is opened and turns the heating off to save energy. When the window is closed, the heater will automatically detect a temperature rise, and switch itself back on. Once enabled in the setup menu, the open window detection is fully automatic and does not require any human intervention to be activated.
    Setting-up Open Window Detection
    The system has been factory set to the default time and temperature values. If necessary, all values can be adjusted. When the heating is on, the open window detection sensor will automatically switch the heater off when it detects a fall in temperature of 2°C in less than 10 minutes (this temperature can be changed in menu 7 and time in menu 6). If a temperature rise of 2°C in less than 30 seconds is detected, the heater will switch itself back on (this temperature can be changed in menu 9 and time in menu 8).
    13. Setup Menu

  23. Press and hold TEMP and MODE together for 5 seconds.

  24. The display will enter the setup menu.

  25. Use TEMP and MODE to change a value.

  26. Use TIME to scroll between the settings.
    01 – temperature calibration
    The temperature reading has been factory calibrated but if for any reason it needs adjusting (better accuracy required, to suit the different positions in the room, etc.), the reading can be recalibrated in 0.5 degrees steps.
    02 – change between degrees Celsius or Fahrenheit
    03 – set minimum temperature (3.5 deg = frost protection)
    **When this is set, the heater will operate in any mode should the room temperature fall below the set temperature.
    04 – set maximum temperature
    When this is set, the maximum temperature in any mode cannot exceed the limit
    05 – open window detection 0 = off, 1 = on
    06 – 600 – open window detection time 600 seconds
    07 – 2 – temperature drop of 2°C in the detection time
    08 – 30 – closed window detection time of 30 seconds
    09 – 2 – temperature rise of 2°C in the detection time
    14. Connection to MRX1
    This LST– RF range is compatible with the MRX multi-zone controller. To pair the LST-RF with the MRX1, set the MRX1 to pairing mode (see section 10 of MRX User Instructions).
    Pairing an RF Timer.
    ** On the electronic RF timer, press and hold TIME and PROG for 10 seconds. The timer will show a unique code, the RF Icon will then flash to show the pairing signal is being sent. Once this has stopped you should see a new 4 digit code showing the pairing was successful. The MRX display shows CONNECTED. Tap BACK and the zone is now connected. To exit pairing mode on the timer press and hold the time button.
    15. Optional PLK1 Locking Device
    The PLK1 locking device can be used to mechanically lock the controls to prevent tampering with settings. As it is not supplied with the heater, kindly contact our Sales team if required.
    – Locking tab
    – Locking screw

  27. If Your Heater Does Not Work
    • Check that power is available to the heater.
    • Check that the thermal cut-out has not operated. Follow the reset instructions given under the section headed ‘Thermal Operated Cut-out’.
    • Check that the fuse in the spur unit has not blown. This can be done by replacing the fuse with another suitable fuse.
    Should none of the above remedies work, then telephone the helpline number shown in these instructions (UK ONLY). Do not attempt to repair the heater.

CUSTOMER HELPLINE
Should you need any advice on the use of your new Consort product please contact our Helpline:
Consort Equipment Products Limited
Thornton Industrial Estate, Milford Haven, Pembrokeshire, SA73 2RT
Tel: 01646 692172
Fax: 01646 695195
Email:technical@consortepl.com
Web:www.consortepl.com
Operation hours: Mon to Thu 8.30 am to 4.30 pm | Fri 8.30 am to 3.30 pm
BS EN ISO 9001 Registered Company No FM12671
66001078 Iss 02

Documents / Resources

| CONSORT LST800ERF Quality Space Heaters [pdf] Installation Guide
LST800ERF, LST500ERF, Quality Space Heaters
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Consort User Manuals

Related Manuals