CONSORT PLSTI150EWIFI PLSTiE Slimline LST Fan Heater Instruction Manual
- June 4, 2024
- Consort
Table of Contents
- CONSORT PLSTI150EWIFI PLSTiE Slimline LST Fan Heater
- General Safety
- SETB – Setback Mode
- PROG – Automatic mode
- Heat symbol on the display
- Set 7-day program
- Connection to the Consort Connect app
- Open Window Detection
- Optional PLK1 Locking Device
- Status light on the heater
- Setup menu
- Keys locking
- If Your Heater Does Not Work
- Control using the Consort Connect app
- Basic settings menu
- Pin number locking
- Energy consumption
- Naming the product in the Consort Connect App
- Setting the automatic program using the app
- Group control
- Smart Automation
- Mounting
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
CONSORT PLSTI150EWIFI PLSTiE Slimline LST Fan Heater
General Safety
Our Low Surface Temperature heaters have been designed and built to the NHS
requirement for safe surface temperatures which is that no surface which can
be touched by the user will be more than 43 ºC (at a room temperature of 21
ºC) This means that our Low Surface Temperature heaters out -perform the
European Standard by a significant margin.
The appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities or lack of experience and
knowledge unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety. Children should
be supervised to ensure that they do not play with the appliance.
Warning
- Do NOT site the appliance in a corner.
- Do NOT handle the appliance with wet hands.
- Do NOT use the appliance in workshops or rooms where excessive dust is generated or present.
- Ensure that nothing is pushed into any aperture of this appliance.
- Do NOT touch outlet grille when the appliance is in use.
- Do NOT cover or restrict any aperture of the appliance when in use.
- Do NOT use the appliance if damaged.
- Do NOT leave the appliance unattended where young children are present.
- If used in a bathroom, the heater is to be installed so that the switches and other controls cannot be touched by a person in the bath or shower.
- Operating temperature range -10 to +40 ºC
- The heater MUST be fully secured in the vertical position before being switched on.
Connection to the WIFI
The heaters only work with a 2.4GHz WIFI network.
Currently all routers support the 2.4GHz band, as it is an older standard and
has maximum device compatibility. Routers can also support 5GHz WIFI and are
often set up to hide which frequency band is being used, combine both bands
into a single network name, and assign the band automatically. A mobile phone
could be automatically connected to the 5GHz network, and this will cause
pairing issues. Routers usually have a setting that gives each band to have a
different network name, which is configurable through the router’s web
interface. This allows the phone to unambiguously select the 2.4GHz network.
For full pairing instructions, see section 10.
Thermally Operated Cut-Out
The appliance is fitted with a thermally operated cut-out (TOC). This is a safety device, which switches the heater off if, for any reason, the appliance overheats. The TOC can only be re-set after the appliance has cooled down. In order to re-set the TOC, proceed as follows:
- Switch off appliance and leave for approximately 10 minutes.
- Switch appliance back on and TOC will re-set.
- Ensure that the appliance is functioning correctly. If the TOC control operates again, the appliance should be checked by a competent electrician.
The heater carries a ‘Do Not Cover’ label to warn the user that if the appliance is covered, there is a risk of overheating.
Cleaning
Always disconnect the heater from the mains before cleaning. The heater should
not require any maintenance, but it is strongly advised that it is kept clean.
An occasional wipe over with a soft cloth is all that should be necessary.
- Do NOT use metal or furniture polish on any part of the heater.
- Do NOT touch the heater with wet hands or in any way bring water into contact with it.
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
Connection to the Main Supply
Electrical installation should be carried out by a competent installer,
preferably registered with NICEIC (National Inspection Council for Electrical
Installation Contracting) in accordance with the latest edition of the IEE
Wiring Regulations, (BS.7671), and any relevant Local Authority Bye-Laws. This
heater is fitted with a 3-core mains supply cable and must be permanently
connected to the electricity supply via a double pole switch having 3mm gap on
each pole. There are no exceptions. A switched Fused Connection unit to
BS.1363. Part 4 is a recommended mains supply connection accessory to ensure
compliance with safety requirements applicable to fixed-wiring installation.
Note: When switched on for the first time the appliance may emit a slight smell. This is purely the evaporation of a fluid used in the manufacturing process.
WARNING: This appliance must be earthed.
Safety Monitor
As part of the intelligent control (see section 15), the heater has built-in
safety monitoring. In the unlikely event of a fault, the safety monitoring
will help prevent high surface temperatures. The safety monitor will identify
overheating, fan failure and certain electronic faults. When the safety
monitor identifies a fault, the heater runs in restricted mode. However, in
the event of a serious fault the heater stops running. The heater indicates a
fault by beeping twice. It will not beep again until the unit is switched off
and then back on, but the LED will flash red continuously.
Intelligent fan control
Depending on which heat mode is activated, the fan will calculate the best
possible airflow temperature and will adjust the fan speed accordingly to
provide maximum comfort and efficiency with minimum noise
NOTE: When turning the heater on, there is a 30 seconds delay until the fan starts running to allow the heater to warm up. After the heater is switched OFF the fan will continue running for a short period of time.
Installation
Mounting bracket
This unit must be installed using the mounting bracket and chains provided.
The chains are used to prevent the unit from being dropped when the securing
screws are loosened. This means the securing screws can simply be loosened to
view behind the heater. This allows the rating label to be viewed easily and
also makes it easier to clean the unit. Full installation instructions can be
found on page 8, section 26.
See diagram below for Mounting
Note: The heater must be secured using the securing screws as per Fig 3
before being switched on.
Basic Operation
Before you can use the heater, it has to be activated by pressing any control button. The LCD backlight will turn on. To operate any control button, press within 2 seconds of activation.
Time and day setting
-
Press and hold the TIME button for 5 seconds.
Minutes are flashing – use TEMP and MODE buttons to set minutes. -
Press TIME button
Hours are flashing – use TEMP and MODE buttons to set hours. -
Press TIME button
Day is flashing – use TEMP and MODE buttons to set Day.
Once you are happy with the settings, press ‘Time’ to return to main screen.
When connected to the app, time will be taken automatically from the internet.
Selecting operating mode
The heater has 4 operating modes:
BOOST, MANUAL, SETB, PROGRAM.
BOOST, MANUAL and PROGRAM can be selected by pressing the MODE button to cycle
through the options. The cycle sequence will always start with BOOST mode
followed by MANUAL, SETBACK and PROGRAM.
BOOST – 15 minutes
The boost feature increases the room temperature for 15 minutes.
- Use TEMP and MODE to set the temperature.
To amend the set temperature when in Boost mode, simply activate the display by pressing any button. Press TEMP, then use TEMP and MODE to change the temperature. Once the temperature is set, you can leave the display to return to the main screen and the settings will be saved. After 15 minutes, the heater will return to previous operating mode.
The 15 minute period can be increased up to 4 hours by using the PROG button.
Pressing this will increase the temperature in 15 minute increments.
This will reset back to 15 minutes after every use.
MAN – Manual Mode
In manual mode, the heater maintains a set temperature between 4°C and 35°C.
- Use TEMP and MODE to set the temperature.
To amend the set temperature when in Manual mode, simply activate the display by pressing any button. Press TEMP, then use TEMP and MODE to change the temperature. Once the temperature is set, leave the display to return to the main screen and the settings will be saved.
SETB – Setback Mode
Setback mode can be used for frost protection, situations where a minimum room
temperature must be maintained. It maintains a temperature between 4°C and
15°C.
To amend the set temperature when in Setback mode, simply activate the display
by pressing any button. Press TEMP, then use TEMP and MODE to change the
temperature. Once the temperature is set, leave the display to return to the
main screen and the settings will be saved. When the room temperature drops
below the set temperature the heating will be active.
PROG – Automatic mode
In this mode, the heater will follow the week’s time / temperature program.
You can temporarily override the temperature in PROG mode by simply activating
the display and using the TEMP and MODE buttons to set the new temperature.
The new set temperature will be then maintained until the next program step.
Heat symbol on the display
Every time there is a demand for heat, the display will show the heat icon.
- Reduced heat output when the room temperature is close to the set temperature – allows for almost silent operation.
- full heat output
Set 7-day program
Each day has 24 time periods, one period for each hour of the day. To set up your program, you must select the required temperature for each time period. Once the day has been selected, the screen will show 2 numbers. The first number represents the hour of the day (10 would represent the 10am-11am heating period) and the sec-ond number represents the temperature. For example, should the display read 10:22, the heater would maintain a temperature of 22°C between 10am and 11am. Once the time has passed 11am, it will move to program.11
Setup instructions
- Press and hold PROG for 5 seconds to enter the program setup menu.
- The day will be flashing, this is the select day menu. Navigate between the days Using the TEMP and MODE buttons.
- Once the required day is flashing press PROG to select it, this brings you to the setup menu for the selected day.
- The display will start with program 0 (midnight-1am). Use the TEMP and MODE buttons to in-crease/decrease the temperature.
- Once you have set the temperature, use the PROG or TIME button to change to the next time period.
- When you advance/return beyond the program range (Prog 0-23) the timer will return to the select day menu.
Use these steps to set the temperature for every hour of every day. It is important to set every hour to avoid the heater operating during unwanted hours.
Copy day function
Should your automatic timer requirements be the same on multiple days, you can
use the copy day function to save time during setup.
To do this, when in the select day section of the program setup menu press and
hold the TIME button. This will bring you to the copy day mode. To select
which day you wish to copy press the PROG button and this will cycle through
numbers 1-7 on the screen, this relates to which day you would like to copy.
1=MON, 2=TUE, 3=WED etc. To select which day you would like to copy the pro-
grammes to, use the TEMP & MODE to navigate to the day. Once both are
selected, press the time button to copy the day.
To exit copy day mode, press and hold the PROG but-ton. This will return the
timer to the main menu.
Connection to the Consort Connect app
Before pairing, the App must be installed on your smart phone. The app is compatible with IOS and Android Smartphones. Go to the app store or play store and search :
Consort Connect
When the app asks for the WIFI make sure that the WIFI network and password
are entered correctly – the app usually selects the right network, but you
need to enter the password. Until you successfully pair a device to a network
it does not remember the password, and if the password is entered incorrectly
it doesn’t specifically tell you that this is the problem.
Pairing the heater to the Consort Connect app.
- Ensure the smartphone or tablet is connected to 2.4GHz WIFI network and the Bluetooth is enabled.
- Press and hold the TIME and PROG buttons for 5 seconds. The timer display will read “Pair”
- select the + symbol in the top right corner of the Consort Connect app
- select “Heater (BLE)”
- The app will ask you to confirm the heater indica-tor is blinking rapidly.
- If the indicator is blinking rapidly, tick the box and click next.
- The app should show that one device has been found. Select the + symbol next to this heater.
- Enter the correct WIFI name and password on the App.
- The heater will begin to pair to the app. This can take up to 60 seconds.
- Once pairing is successful, the + symbol will be replaced with a tick.
- Select Next and the app should display ‘Added successfully’. The heater is now paired and ready to be used with the app.
- A solid RF symbol on the timer means the heater is connected to the internet. The time is automati
If the pairing is unsuccessful, check the points below and retry.
- Ensure you are using a 2.4Ghz WIFI network.
- Ensure you have a solid internet connection.
- Ensure you have entered the network name and password correctly.
- Check if the heater has appeared on the home page in the app.
- Ensure Bluetooth is enabled.
Open Window Detection
Ensuring you don’t waste energy on heating the outside world, the heater is equipped with optional open / closed window detection. The heater recognizes sudden drops in temperature when a window or a door is opened and turns the heating off to save energy. When the window is closed, the heater will automatically detect a temperature rise, and switch itself back on. This is enabled in the setup menu.
Setting-up Open Window Detection
The system has been factory set to default time and temperature values. All
values can be adjusted. when the heating is on, open window detection sensor
will automatically switch the heater off when it detects a fall in temperature
of 2°C in less than 10 minutes (this temperature can be changed in menu 7 and
time in menu 6). If a temperature rise of 2°C in less than 30 seconds is
detected, the heater will switch itself back on (this temperature can be
changed in menu 9 and time in menu 8). These changes can also be made in the
app. When viewing the heater settings, select the ‘open window detection’
menu.
Optional PLK1 Locking Device
The PLK1 locking device can be used to mechanically lock the controls to prevent tampering with settings. As it is not supplied with the heater, kindly contact our Sales team if required.
Status light on the heater
Setup menu
- Press and hold TEMP and MODE together for 5 seconds.
- The display will enter the setup menu.
- Use TEMP and MODE to change a value.
- Use TIME to scroll between the settings.
01 – temperature calibration
The temperature reading has been factory calibrated but if for any reason it
needs adjusting (better accuracy required, to suit different position in the
room etc.), the reading can be recalibrated in 0.5 degrees steps.
02 – change between degrees Celsius or Fahrenheit
03 – set minimum temperature (4°C = frost protection)
When this is set, the heater will operate in any mode should the room
temperature fall below the set temperature.
04 – set maximum temperature
When this is set, the maximum temperature in any mode cannot exceed the
limit.
05 – open window detection 0 = off, 1 = on
06 – 600 – open window detection time 600 seconds
07 – 2 – temperature drop of 2°C in the detection time 08 – 30 – closed window
detection time of 30 seconds 09 – 2 – temperature rise of 2°C in the detection
time
Keys locking
Press and hold TIME and TEMP together for 5 seconds. The display will show symbol. Repeat the step to unlock.
If Your Heater Does Not Work
- Check that power is available to the heater. The LED on the front of the heater should be illuminated
- Check that the thermal cut-out has not operated. Follow the reset instructions given under the section headed ‘Thermal Operated Cut-out’.
- Check that the fuse in the spur unit has not blown. This can be done by replacing the fuse with another suitable fuse.
Should none of the above remedies work, then telephone the helpline number shown in these instructions (UK ONLY). Do not attempt to repair the heater.
Control using the Consort Connect app
Basic control of an individual heater
When you open the Consort Connect app, select the heater you would like to
control. This will bring you to the main page for controlling the heater. In
this page, you can change the operating mode and comfort temperature on this
screen. The dial in the middle of the screen is used to adjust the
temperature. The icons on the top of the screen are used to change the
operating mode.
Basic settings menu
In the settings menu, select the title ‘basic’ to access the basic menu. In this menu, you can view the wattage of the heater, adjust the temperature correction and tog-gle open window detection.
Pin number locking
The lock feature allows you to lock 2 different aspects of the system using a
pin number. You can either lock the heater completely so that it cannot be
tampered with, or only lock the WIFI pairing. Locking the WIFI pairing
prevents people from pairing the heater to their smartphones unless they have
the pin.
These settings can be implemented under the title ‘Lock’ in the settings menu.
You cannot view the lock settings until the WIFI pairing lock is enabled.
To disable the pairing lock via the timer, hold down the TIME and PROG
buttons. To disable the heater lock via timer, hold down the TIME and TEMP
buttons.
This will prompt you to enter a 4-digit pin. Enter the 4-digit pin using the
TEMP and MODE buttons to select a value, the TIME button to advance to the
next digit, and the PROG button to confirm.
Once the pin has been entered, the lock is disabled and the pin does not need
to be re-entered.
NOTE: Once this pin has been confirmed, the lock can-not be removed without knowing the correct pin number.
The pin is NOT recoverable.
Energy consumption
Selecting the icon will load the Energy consumption menu. This menu shows how
much power the individual heater has used in the last day, week, month and
year.
The energy usage values are approximate. They are based on recording time the
heaters are producing heat. The mains voltage and actual heater wattage aren’t
taken to account when calculating values.
Naming the product in the Consort Connect App
Once the heater is linked with the app, it is given a gener-ic name and icon.
These can both be changed.
To do this, when the controller menu is open (this is the menu you can control
the product with) select the
icon in the top right corner of the screen. Next, select the icon again. From
this page, you can change the name of the controller and import an image to
represent your product.
Setting the automatic program using the app
The 7-day program can be set using the app instead of the electronic timer. To
access the program page, select the icon. This 7-day program is the same as
the one discussed in section 8. Modifying the program on the app will modify
the program on the timer automatically.
Tapping an hour slot will turn it grey and bring up 2 options. These are
‘Delete’ and ‘Settings’. Tapping delete will de-fault the temperature for that
slot to 4°C . Tapping settings will allow a temperature between 4°C and 40°C
to be selected.
Multiple hour slots can be selected at once provided they are on the same day
and in a row. For example, if the pro-gram needed to be 22°C from 9am-5pm on
Monday you would need to follow the steps below.
- Select the box after 09:00 Monday (the box will turn grey)
- Scroll down and select the box before 17:00 on Monday. All boxes from 09:00 up to 17:00 will turn grey.
- Select the option ‘settings’ which appears next to the grey boxes.
- Select a temperature of 22°C.
- Tap ‘Done’
- All boxes between 09:00 and 17:00 will be set to 22°C and the heater will maintain this temperature during these times.
Repeat these steps for all time periods so that the heater runs as required.
Group control
The APP can be set for group control where it is possible to control multiple
heaters at once.
To set it up, open the app, select a heater you want in the group and press
the edit icon in the top right hand corner. Select create group and follow the
instructions on the screen.
Smart Automation
The automatic program which is explained previously is only capable of
switching the heating on/off in one hour increments, I.e. the heating could
not be switched on at 10:30am, it would need to be either 10am or 11am.
The Smart automation feature which is only available via the app can offer a
solution to this. It allows an unlimited amount of programs to be set on every
day of the week. To use it, follow the steps listed below.
- Open the Consort Connect app and select the ’Smart’ option on the bottom of the screen.
- Select the ‘+’ symbol located in the top right of the screen.
- Select the option ‘Schedule’
- Select ’Repeat’ and choose the days which the program is required to run on.
- Select an execution time. This is the time the pro-gram will be triggered.
- Select ‘Next’.
- Select ‘Run the device’ and choose the device the program will control.
- Select ‘Mode’ and then choose the operating mode the heater will switch to.
- Select ‘Name’ to name the operation (optional).
- Select ‘Save’.
Repeat these steps for all automations required. A single time period would require two automations, one to switch the heater on, and one to switch the heater off.
You can activate/deactivate each individual automation without deleting it. To do this, from the main app screen select the ‘Smart’ option and use the toggle icon.
Mounting
This unit is for wall mounting only. It is designed to be very quiet in
operation if mounted correctly. It must be fitted using the wall bracket
supplied and screws for a 5mm hole. The wall bracket provided has been
specially designed to minimize noise levels. Care must be taken w hen
handling the bracket not to bend or distort it. When fitting more than one
heater in a room we would recommend that they are sited on the same wall to
optimize airflow and ensure quiet operation.
To wall mount, the wall bracket supplied must be used. Remove the wall bracket
from the heater. Fix the wall bracket to the wall using 4 screws. Present the
heater to the bracket. Locate the heater onto the bottom lugs via the 2 slots
in rear panel. Hinge the heater upwards and attach the chain assembly, then
move the heater to the upright position. The link plates should slide under
the slotted bracket lip.
MOUNTING ON A PLASTERBOARD WALL
- Ensure at least one of the wall brackets is secured to the timber frame of the studded wall by using standard wood screws.
- Where the bracket is fitted onto plasterboard only, ensure plasterboard fixings are used. Standard wall plugs will not be suitable.
- Where possible mount the heater(s) on an outside wall to inhibit transfer of sound within the building.
NB: Failure to follow the instructions and recommendations provided could
result in increased noise levels.
The heater must not be located immediately below a fixed socket outlet.
Refer to page 3 for more information.
THORNTON INDUSTRIAL ESTATE, MILFORD HAVEN, PEMBROKESHIRE, SA73 2RT.
UK TEL: +44 1646 692172
E-MAIL: TECHNICAL@CONSORTEPL.COM
WWW.CONSORTEPL.COM
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>