Teleflex AK-25703-A Three-Lumen CVC User Guide

June 5, 2024
Teleflex

Teleflex LOGO

AK-25703-A
7 Fr.
3 Lumen
20cm
catheter
.032inchdia.
spring-wire
guide
Arrowg+ard Blue® Three-Lumen CVC

1: Arrowg+ard Blue® Three-Lumen Catheter: 7 Fr. (2.5 mm OD) x 20 cm
1: Drape: 24″ x 36″ (61 cm x 91 cm) with 4″ (10 cm) fenestration
1: Spring-Wire Guide, Marked: .032″ (0.81 mm) dia. x 23-5/8″ (60 cm) (Straight
1: Scalpel: #11 Soft Tip on One End – “J” Tip on Other) with Arrow Advancer
2: Gauze Pad: 2″ x 2″ (5 cm x 5 cm)
1: Catheter: 18 Ga. x 2-1/2″ (6.35 cm) Radiopaque over 20 Ga. RW Introducer
5: Gauze Pad: 4″ x 4″ (10 cm x 10 cm) Needle
1: Suture: 3-0 Braided Silk with Straight Needle
1: Injection Needle: 25 Ga. x 1″ (2.54 cm) 1A registered trademark of CareFusion or one of its subsidiaries.
1: Blunt Fill Needle: 18 Ga. x 1-1/2″ (3.81 cm) 1: Pressure Transduction Probe
1: Introducer Needle: 18 Ga. x 2-1/2″ (6.35 cm) XTW and 5 mL Arrow® Raulerson Spring-Wire Introduction Syringe
1: Injection Needle: 22 Ga. x 1-1/2″ (3.81 cm) and 5 mL Luer-Slip Syringe
1: Syringe: 3 mL Luer-Lock
1: Tissue Dilator 8.5 Fr. (2.8 mm) x 10.2 cm
1: 5 mL 1% Lidocaine HCI Solution and Alcohol Prep
1: 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®1 One-Step Solution with Hi- Lite OrangeTM Tint
3: Dust Cap: Non-Vented
1: SecondSiteTM Adjustable Hub: Fastener
1: SecondSiteTM Adjustable Hub: Catheter Clamp
1: SharpsAway® Disposal Cup

​Rx only Warning: Read all package insert warnings, precautions, and instructions prior to use. Failure to do so may result in severe patient injury or death. California Prop. 65 WARNING: Cancer and Reproductive Harm. www.P65Warnings.ca.gov Not made with natural rubber latex. Store between 20 – 25°C (68 – 77°F). Sterilized using ethylene oxide unless otherwise indicated in the contents list. Fluid path components are non-pyrogenic. Contraindications: The Arrowg+ard Blue antimicrobial catheter is contraindicated for patients with known hypersensitivity to chlorhexidine, silver sulfadiazine, and/or sulfa drugs.

| Priming Volume* (mL)| Gravity Flow Rate† (mL/hr)
---|---|---
Distal(16Ga.)| 0.4| 2258
Medial(18Ga.)| 0.4| 1046
Proximal(18Ga.)| 0.4| 1154

  • Priming volumes are approximate and are done without accessories. t Flow rate values are approximate and are determined using deionized water at 100 cm head height. Teleflex AK 25703 A Three-Lumen CVC - icon 1

Arrow International LLC
A subsidiary of Teleflex Incorporated
3015 Carrington Mill Blvd.
Morrisville, NC 27560 USATeleflex LOGOwww.telefiex.com
LBL052069 R01 (2022-02)