TECHNICAL SPECIFICATIONS
PRELIMINARY WARNINGS
- The word WARNING preceded by the symbol indicates conditions or actions that put the user’s safety at risk.
- The word ATTENTION preceded by the symbol indicates conditions or actions that might damage the instrument or the connected equipment. The warranty shall become null and void in the event of improper use or tampering with the module or devices supplied by the manufacturer as necessary for its correct operation, and if the instructions contained in this manual are not followed.
| WARNING : The full content of this manual must be read before any operation. The module must only be used by qualified electricians. Specific documentation is available via QR-CODE shown on page 1.
---|---
| The module must be repaired and damaged parts replaced by the Manufacturer. The product is sensitive to electrostatic discharges. Take appropriate measures during any operation.
| Electrical and electronic waste disposal (applicable in the European Union and other countries with recycling). The symbol on the product or its packaging shows the product must be surrendered to a collection centre authorized to recycle electrical and electronic waste.
SETTING THE DIP-SWITCHES
The position of the DIP-switches defines the Modbus communication parameters of the module: Address and Baud Rate The following table shows the values of the Baud Rate and the Address according to the setting of the DIP-switches:
DIP-Switch status
SW1 POSITION| BAUD RATE| SW1 POSITION| ADDRESS|
POSITION| TERMINATOR
1 2 3 4 5 6 7 8| 3 4 5 6 7 8| 10
| | | | 9600| |
| | | | | | | | | | | | #1| | | | Disabled
| | | | | | | |
| | | | 19200| |
| | | | | | | | | | | | #2| | | | Enabled
| | | | 38400|
| #…| |
| | | | 57600| |
| | | | | | | | | | | | #63|
|
|
From
EEPROM
| |
From
EEPROM
|
Note:
When DIP switches 1 to 8 are OFF, the communication settings are taken from
programming (EEPROM). ؔ
Note 2:
The RS485 line must be terminated only at the ends of the communication
line.
DIP-SWITCHES
SW1|
All DIP switches in OFF position.
For further information, refer to the USER MANUAL.
SW2
|
RS232 or RS485 settings on terminals 10-11-12 (COM2 serial port)
RS232| ON|
RS485| OFF|
CONFIGURATION OF FACTORY SETTINGS
All DIP-switches in| OFF| |
---|---|---|---
Communication parameters of ModBUS protocol: RS485 and RS482/232 ports| 38400,
8, N, 1 Address 1
Communication parameters of micro USB port| 115200, 8, N, 1 Address 1
Analogue Input 1-2| VOLTAGE
ModBUS CONNECTION RULES
- Install the modules in the DIN rail (120 max)
- Connect the remote modules using cables of an appropriate length. The following table shows cable length data:
- Bus length: maximum length of the Modbus network according to the Baud Rate. This is the length of the cables that connect the two farthest modules (see Diagram 1).
- Derivation length: maximum length of a derivation 2 m (see Diagram 1).
For maximum performance, it is recommended to use special shielded cables, such as BELDEN 9841.
Bus length | Derivation length |
---|---|
1200 m | 2 m |
INSTALLATION REGULATIONS
The module has been designed for vertical installation on a DIN 46277 rail. For optimal operation and long life, adequate ventilation must be provided. Avoid positioning ducting or other objects that obstruct the ventilation slots. Avoid mounting modules over heat-generating equipment. Installation in the bottom part of the electrical panel is recommended.Insertion in the DIN rail As shown in figure:
- Insert the IDC10 rear connector of the module on a free slot of the DIN rail (the insertion is univocal since the connectors are polarized).
- To secure the module to the DIN rail, tighten the two hooks on the sides of the IDC10 rear connector.
Power supply and Modbus interface are available using the Seneca DIN rail bus,
via the IDC10 rear connector, or the Z-PC-DINAL-17.5 accessory.
USB
PORT
The module is designed to exchange data according to the modes defined by the
MODBUS protocol. It has a micro USB connector and can be configured using
applications and/or software programs. The USB serial port uses the following
communication parameters: 115200,8,N,1 The USB communication port responds
exactly like the RS485 or RS232 ports with the exception of the communication
parameters. EASY SETUP is the software to use for the configuration. For
further information go to the following website: www.seneca.it/products
/ze-4di-2ai-2do –
www.seneca.it/products/z-4di-2ai-2do – www.seneca.it/products/ze-2ai
- Check that the device in question is included in the list of products supported by the Easy Setup APP in the store. Check that the device in question is included in the list of products supported by the Easy Setup APP in the store.
ELECTRICAL CONNECTIONS
Attention:
the upper power supply limits must not be exceeded, as this might cause
serious damage to the module.
To meet the electromagnetic immunity requirements:
- use shielded signal cables;
- connect the shield to a preferential instrumentation earth system;
- separate shielded cables from other cables used for power installations (transformers, inverters, motors, induction ovens, etc…).
POWER SUPPLY
ANALOGUE
INPUTS
Voltage
| Active sensor current (4 wires)|
Passive sensor current (2 wires)
| The module has two analogue inputs that can be configured via software as
voltage or current. For the configuration software, see the user manual
---|---|---|---
| | | ****
| | |
DIGITAL INPUTS (ONLY ZE-4DI-2AI-2DO and Z-4DI-2AI-2DO) DIGITAL OUTPUTS (ONLY ZE-4DI- 2AI-2DO and Z4DI-2AI-2DO)
N.A.1=19 CO.1=20 N.C.1=21| N.A.2=22 CO.2=23 N.C.2=24| The has two digital outputs with free contacts.
The two figures show the internal relay contacts available.
---|---|---
COM2 SERIAL PORT
| | | The
module has a COM2 port
---|---|---|---
configurable via the SW2 switch
on terminals 10 -11-12
MODULE LAYOUT
Single
module dimensions LxHxD: 17.5 x 102.5 x 111 mm;
Weight: 110 g;
Enclosure: PA6, black
Double module dimensions LxHxD: 35 x 102.5 x 111 mm;
Weight: 110 g;
Enclosure: PA6, black
LED SIGNALS ON THE FRONT PANEL (ZE-4DI-2AI-2DO)
LED
| STATUS| MEANING
---|---|---
IP/ PWR (Green)| ON|
Module powered and IP address acquired
IP/ PWR (Green)
| Flashing| Powered module. Waiting for IP address from DHCP server
Tx/ Rx (Red)| Flashing|
Transmission and reception of data on at least
one Modbus port: port COM 1, port COM 2
ETH TRF (Green)
| Flashing| Packet transmission on Ethernet port
ETH LNK (Yellow)| ON|
Ethernet port connected
DI1, DI2, DI3, DI4 (Red)
| On / Off| Status of digital input 1, 2, 3, 4
DO1, DO2 (Red)| On / Off|
Status of output 1, 2
FAIL (Red)
| Flashing|
Outputs in fail condition
LED SIGNALS ON THE FRONT PANEL (Z-4DI-2AI-2DO)
LED
| STATUS| MEANING
---|---|---
PWR (Green)| ON|
Module powered
Tx/ RX (Red)
| Flashing| Transmission and reception of data on at least
one Modbus port: port COM 1, port COM 2
DI1, DI2, DI3, DI4 (Red)|
On / Off
|
Status of digital input 1, 2, 3, 4
DO1, DO2 (Red)
| On / Off| Status of output 1, 2
FAIL (Red)| Flashing|
Outputs in fail condition
LED SIGNALS ON THE FRONT PANEL (ZE-2AI)
LED
| STATUS| MEANING
---|---|---
IP/ PWR (Green)| ON|
Module powered and IP address acquired
IP/ PWR (Green)
| Flashing| Powered module. Waiting for IP address from DHCP server
FAIL (Red)| ON|
At least one of the two analogue inputs is out of scale (underscale-overscale)
ETH TRF (Green)
| Flashing| Packet transmission on Ethernet port
ETH LNK (Yellow)| ON|
Ethernet port connected
Tx1 (Red)
| Flashing| Modbus packet transmission from device to port COM 1
Rx1 (Red)| Flashing|
Modbus packet transmission to port COM 1
Tx2 (Red)
| Flashing| Modbus packet transmission from device to port COM 2
Rx2 (Red)| Flashing|
Modbus packet transmission to port COM 2
CONTACT INFORMATION
Technical support
| support@seneca.it| Product information|
---|---|---|---
References
- Z-4DI-2AI-2DO | ModBUS mixed I/O Modules | SENECA
- ZE-2AI | Analog I/O Modules | SENECA
- ZE-4DI-2AI-2DO | ModBUS mixed I/O Modules | SENECA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>