SAFETY INFORMATION
Disconnect the power supply before attempting any work on the unit!
- Installing these units involves work on the mains voltage supply; installation must therefore be carried out professionally in accordance with the appliance national wiring regulations and electrical operating conditions.
- The product must be installed by a licensed professional electrician.
- Check all components for damage, do not use the product if it is damaged.
- To ensure the product can work normally, please use it in the voltage within the range on the lamp label.
- The floodlight enclosure heats up when the light is on. Only adjust the angle of the LED panel once it has cooled down. Do not look into the LED light at a short range or any prolonged period(>5 min).
- Do not install the unit on (normally) flammable surfaces.
- Do not alter or change parts of the light at will, in case of the accidents such as breakage, fall, electric shock, fire, etc.
PARAMETER
| A –
399×120.5×144 mm 15.7×4.7×5.6 in
B – 313x133x138 mm 12.3×5.2×5.4 in
C – 364x112x195 mm 14.3×4.4×7.7 in
D – 455x120x182 mm 17.9×4.7×7.1 in
---|---
| 100-120V AC 60Hz 220-240V AC 50Hz
| Daylight White 6000K
| IP65
| -25°C – 40°C
COMPONENTS AND STRUCTURE
-
Cover
-
LED Light Source
-
Lamp Bracket
-
Sensor Head
-
SENS adjustable: It can be adjusted according to using location; low sensitivity with 5m for detection distance; high sensitivity with 10m, it fits for large room.
-
Can identify day and night: The consumer can adjust work ambient light. It can work in the daytime and at night when it is adjusted on the “+” position (max). It can work in the ambient light less than 10LUX when it is adjusted on the “moon” position (min). As for the adjustment pattern, please refer to the testing pattern.
-
Time-delay adjustment: It can be set according to the consumer’s desire. The minimum time is 10sec±3sec. The maximum is 7min±2min. Time-delay is added continually: When it receives the second induction signals after the first induction, it will compute time once more on the rest of the first time-delay basic (set time).
Detection Range: 180°
Installation Height: 1.8m~2.5m
NOTE
- Make sure that the distance between the light and the object being lit is more than 1 meter, so as to avoid high temperature caused by short distance.
- Caution, risk of electric shock.
- Earth wire is required for connection for electric safety.
Non-User Replaceable Light Source
The light source contained in this flood light shall only be replaced by the
manufacturer or his service agent or a similar qualified person.
Limitation of Indoor and Outdoor Use
- This light is waterproof and dustproof. It is protected against the rain, but it cannot be immersed in water.
- The mounting position of this light should be able to bear at least 10 times as heavy as the light.
- This light is powered by High Voltage Alternating Current (HVAC). It should be connected to the ground wire and kept away from easy reach.
- This light should be used in condition with sound heat dissipation. The working temperature of it should be less than 45°C. Overhigh working temperature will cause serious lumen depression and affect lifespan of the light.
INSTALLATION STEPS
-
Step 1: Stick EVA cotton pad on the metal panel. Drill two holes on the wall, fix the metal panel onto the wall with plastic expansion
nails and screws. Note: Please estimate and identify the distance and size of the holes before drilling, and the metal panel has to be horizontally placed. -
Step 2: Pass your power cord through the hole of metal panel. Then connect the Neutral line, Live line and Ground wire of power cord with the corresponding wires.
-
Step 3: Thread the long screw into the silicone ring and insert it into socket hole. Tighten it to the metal panel with an Allen key to make sure the lights is firmly fixed.
Note:
- For wet location, make sure fill full the gap of EVA gasket and mouting surface with sealing compound or silicon glue.
- Mounting above 1.2m (4ft) of ground.
Note:
If the light still emits a faint light without detecting the movement, please
exchange the neutral wire (white wire) and the live wire (black wire).
For US:
Connect the black line and white line of the light with the Live line and
Neutral line of main supply respectively. Earth the green ground wire and then
plug in the power supply.
Note:
If the light still emits a faint light without detecting the movement, please
exchange the neutral wire (blue wire) and the live wire (brown wire).
For EU :
Connect the brown line and blue line of the light with the Live line and
Neutral line of main supply respectively. Earth the yellow-green ground wire
and then plug in the power supply.
OPERATION & MAINTENANCE
- Prior to cleaning the light, make sure it has been disconnected from the power supply.
- The unit is not suitable for burglar alarm systems as it is not tamperproof in the manner prescribed for such systems.
- Never use any chemicals or corrosive substances for cleaning.
DISPOSAL
Electrical and electronic equipment, accessories and packaging must be
recycled in an environmentally compatible manner.
- Do not dispose of electrical and electronic equipment as
domestic waste.
EU countries only:
Under the current European Directive on Waste Electrical and Electronic
equipment and its implementation in national law, electrical and electronic
equipment no longer suitable for use must be collected separately and recycled
in an environmentally compatible manner.