ONFORU D50 LED Flood Light Instruction Manual
- June 5, 2024
- ONFORU
Table of Contents
ONFORU D50 LED Flood Light
SAFETY INFORMATION
Disconnect the power supply before attempting any work on the unit!
- Installing these units involves work on the mains voltage supply; installation must therefore be carried out professionally in accordance with the appliance national wiring regulations and electrical operating conditions.
- The product must be installed by a licensed professional electrician.
- Check all components for damage, do not use the product if it is damaged.
- To ensure the product can work normally, please use it in the voltage within the range on the lamp label.
- The floodlight enclosure heats up when the light is on.Please adjust the angle of the light after the power off for 10-15 minutes. Do not look into the LED light at a short range or any prolonged period(>5 min).
- Do not install the unit on (normally) flammable surfaces.
- Do not alter or change parts of the light at will, in case of the accidents such as breakage, fall, electric shock, fire, etc.
- Only to be installed outside arm’s reach
- The light is IP66 waterproof, but the plug is non-waterproof. Please connect the plug indoor or connect to a socket that provides IP65 protection.
- Please use tools to adjust the lights.
- The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced.
- Never plug the light in with wet hands in case of electric shock.
- This light is a non-dimmable product. To avoid failure, please don’t connect it with the dimming controller.
- Do not connect this light fixture to an ungrounded electrical system.
- WARNING: Installing this light in an ungrounded electrical system may cause the metal parts of the light to carry current if any wires or wire connections are damaged or loose. In this case, anyone who touches the light will receive an electric shock, resulting in injury or death. Be sure to use wire nuts/connectors rated for the correct gauge and number of wires used.
- NOTE: Make sure there are no exposed wire bundles outside the wire nut/connector (if applicable).
- Be careful not to damage or cut the wire insulation (covering) during installation. Do not let the wires touch any sharp edges.
- The floodlight is supplied with cable and must be terminated using a terminal block (not supplied) in a suitable IP rated enclosure (not included).
- For type Z attachments:
- The external flexible cable or cord of this luminaire cannot be replaced; if the cord is damaged, the luminaire shall be destroyed.
PARAMETER
- Max Projected Area
- A: 0.0065² B: 0.0105m² C: 0.0105m² D: 0.0265m² E: 0.0243m² F: 0.0616m² G: 0.0749m²
- Max. Lighting Coverage
- A: 20m² B: 35m² C: 35m² D: 80m² E: 80m² F: 160m² G: 256m²
COMPONENTS AND STRUCTURE
- Tempered Glass Lid
- LED Light Source
- Lamp Bracket
NOTE
- Make sure that the distance between the light and the object being lit is more than 1 meter, so as to avoid high temperature caused by short distance.
- Earth wire is required for connection for electric safety.
- Lights that are not suitable for covering with thermal insulation materials.
Limitation of Indoor and Outdoor Use
- This light is waterproof and dustproof. It is protected against the rain, but it cannot be immersed in water.
- The mounting position of this light should be able to bear at least 10 times as heavy as the light.
- This light is powered by High Voltage Alternating Current (HVAC). It should be connected to the ground wire and kept away from easy reach.
- This light should be used in condition with sound heat dissipation. The working temperature of it should be less than 40°C. Overhigh working temperature will cause serious lumen depression and affect lifespan of the light.
INSTALLATION STEPS
- Step 1: According to the spacing (see the “A” part of the picture) of two screw bits on the LED Light bracket, drill two mounting holes.
- Step 2: Put the bracket onto the prepared mounting holes and then screw it on.
- Step 3: Adjust the beam direction as you like, Wiring.
NOTE: Recommended to be installed on the ground above 2.5 m (8.2 ft) and no higher than 5 m (16.4 ft).
For US:
Connect the black line and white line of the light with the Live line and
Neutral line of main supply respectively. Earth the green ground wire and then
plug in the power supply.
OPERATION & MAINTENANCE
- Prior to cleaning the light, make sure it has been disconnected from the power supply.
- The unit is not suitable for burglar alarm systems as it is not tamperproof in the manner prescribed for such systems.
- Never use any chemicals or corrosive substances for cleaning.
DISPOSAL
- Electrical and electronic equipment, accessories and packaging must be recycled in an environmentally compatible manner.
- Do not dispose of electrical and electronic equipment as domestic waste.
EU countries only:
Under the current European Directive on Waste Electrical and Electronic
equipment and its implementation in national law, electrical and electronic
equipment no longer suitable for use must be collected separately and recycled
in an environmentally compatible manner.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>