ONFORU CTB96RGB RGB LED Light Instruction Manual

June 5, 2024
ONFORU

ONFORU CTB96RGB RGB LED Light

ONFORU-CTB96RGB-RGB-LED-Light-product

SAFETY INFORMATION

Disconnect the power supply before attempting any work on the unit!

  • Installing these units involves work on the mains voltage supply; installation must therefore be carried out professionally in accordance with the appliance national wiring regulations and electrical operating conditions.

  • The product must be installed by a licensed professional electrician.

  • Check all components for damage, do not use the product if it is damaged.

  • To ensure the product can work normally, please use it in the voltage within the range on the lamp label.

  • The floodlight enclosure heats up when the light is on.Please adjust the angle of the light after the power off for 10-15 minutes. Do not look into the LED light at a short range or any prolonged period(>5 min).

  • Do not install the unit on (normally) flammable surfaces.

  • Do not alter or change parts of the light at will, in case of the accidents such as breakage, fall, electric shock, fire, etc.

  • To reduce the risk of strangulation the flexible wiring connected to this luminaire shall be effectively fixed to the wall if the wiring is within arm’s reach

  • The light is IP66 waterproof, but the plug is non-waterproof. Please connect the plug indoor or connect to a socket that provides IP65 protection.

  • Please use tools to adjust the lights.

  • The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced.

  • Never plug the light in with wet hands in case of electric shock.

  • This light is a non-dimmable product. To avoid failure, please don’t connect it with the dimming controller.

  • Do not connect this light fixture to an ungrounded electrical system.

  • WARNING : Installing this light in an ungrounded electrical system may cause the metal parts of the light to carry current if any wires or wire connections are damaged or loose. In this case, anyone who touches the light will receive an electric shock, resulting in injury or death.

  • Be sure to use wire nuts/connectors rated for the correct gauge and number of wires used. NOTE: Make sure there are no exposed wire bundles outside the wire nut/connector
    (if applicable).

  • Be careful not to damage or cut the wire insulation (covering) during installation. Do not let the wires touch any sharp edges.

  • The floodlight is supplied with cable and must be terminated using a terminal block (not supplied) in a suitable IP rated enclosure (not included).

  • For type Z attachment The external flexible cable or cord of this luminaire cannot be replaced; if the cord is damaged, the luminaire shall be destroyed.

PARAMETER

ONFORU-CTB96RGB-RGB-LED-Light-fig-1

| A- 430x80x79 mm / 16.93×3.15×3.11 in

B- 430x110x110 mm / 16.93×4.33×4.33 in

C- 430x140x110 mm / 16.93×5.5×4.33 in

---|---
| A- 0.90 kg / 1.98 Ib

B- 1.21 kg / 2.67 in

C- 1.60 kg / 3.53 in

| 100-120V~60Hz 220-240V~50Hz
| RGB
| IP66
ta| -25°C – 40°C/-4°F-104°F
chromaticity coordinate| x=0.2053 y=0.192
PF| >0.9

The intended purpose of this special purpose product: This light is used to create atmosphere. it is not suitable for household room illumination the light source is not intended for use in other applications.

COMPONENTS AND STRUCTURE

ONFORU-CTB96RGB-RGB-LED-Light-fig-2

Max Projected Area

  • A: 0.0255m²
  • B: 0.0309m²
  • C: 0.0346m²
  • D: 0.0542m
  1. Tempered Glass Lid
  2. LED Light Source
  3. Lamp Bracket
  4. Screws For Mounty
  5. Plastic Expansion Nails
  6. Screws
  7. Lamp Brackets
  8. Hex Screw Key
  9. Remote Control

With Memory function, the light can start at your last choice of color and mode.

  1. Brightness Adjustment: Press the to either increase or decrease the brightness; There are 8 levels of adjustable brightness.
  2. Stop: Pause color changes in the jump mode, fade mode, flash mode, or automatic mode.
  3. On/Off: Turn on or off the light by pressing ” “
  4. Color Options: Press the colored buttons to select corresponding light.
  5. DIY Mode: After pressing the button DIY1 \ DIY2 \ DIY3, you can DIY different colors by adjusting the RGB brightness through these 6 keys, and these colors are automatically saved; there are 17 variations of colors, and more than 4,800 colors are available for you to choose. 3 kinds of DIY colors can be saved as DIY1 \ DIY2 \ DIY3.
  6. Speed Adjustment: Adjust the speed of color changes in Jump Mode, Fade Mode and Flash Mode; press the button QUICK to speed up and SLOW to slow down. And 30 kinds of different speed are available for you to choose.
  7. Timing: There are 3 regular intervals 3H\6H\12H to set the timer and the light will be off automatically when the time is up.
  8. Auto Mode: Freely switch Jump Mode, Fade Mode, or Flash Mode.
  9. Flash Mode: Make the light flash.
  10. Fade Mode: FADE3 is the mode of three color gradients, and FADE3 is the mode of seven color gradients.
  11. Jump Mode: JUMP3 is the mode of three color jumps, and JUMP7 is the mode of seven color jumps.
  12. Remove the insulation sheet before using the remote control.

Replace the batteries of the remote control by referring to the figure on the right.

NOTE

ONFORU-CTB96RGB-RGB-LED-Light-fig-5

  1. Make sure that the distance between the light and the object being lit is more than 1 meter, so as to avoid high temperature caused by short distance.
  2. Earth wire is required for connection for electric safety.
  3. Lights that are not suitable for covering with thermal insulation materials.
  4. It is not suitable for household room illumination.

Limitation of Indoor and Outdoor Use

  1. This light is waterproof and dustproof. It is protected against the rain, but it cannot be immersed in water.
  2. The mounting position of this light should be able to bear at least 10 times as heavy as the light.
  3. This light is powered by High Voltage Alternating Current (HVAC). It should be connected to the ground wire and kept away from easy reach.
  4. This light should be used in condition with sound heat dissipation. The working temperature of it should be less than 40°C. Overhigh working temperature will cause serious lumen depression and affect lifespan of the light.

INSTALLATION STEPS

ONFORU-CTB96RGB-RGB-LED-Light-fig-6

  1. Step 1: Fix the bracket on the lamp with the combination screw. (as shown in the image)
  2. Step 2: According to the spacing (see the “A” part of the picture) of four holes on the lamp brackets, drill four mounting holes. (as shown in the image)
  3. Step 3: Put the brackets onto the prepared mounting holes and then screw them on.
  4. Step 4: Adjust the beam direction as you like, and then plug into the main socket.

NOTE : Recommended installation height not higher than 5 m (16.4 ft)

OPERATION & MAINTENANCE

  • Prior to cleaning the light, make sure it has been disconnected from the power supply.
  • The unit is not suitable for burglar alarm systems as it is not tamperproof in the manner prescribed for such systems.
  • Never use any chemicals or corrosive substances for cleaning.

DISPOSAL

Electrical and electronic equipment, accessories and packaging must be recycled in an environmentally compatible manner. Do not dispose of electrical and electronic equipment asV domestic waste.

EU countries only:
Under the current European Directive on Waste Electrical and Electronic equipment and its implementation in national law, electrical and electronic equipment no longer suitable for use must be collected separately and recycled in an environmentally compatible manner

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ONFORU User Manuals