ONFORU BDB55D-3 LED Dusk to Dawn Wall Light User Guide
- June 5, 2024
- ONFORU
Table of Contents
ONFORU BDB55D-3 LED Dusk to Dawn Wall Light
COMPONENTS AND STRUCTURE
PARTS LIST
SPECIFICATIONS
LED WALL LAMP
Model| BDB55D-3| BDJ55D-3| BDI45D-2| BDC80D-3| BDD100D-3| BDL40D-3
Input Current| 0.5A| 0.5A| 0.38A| 0.58A| 0.83A| 0.35A
Rated Power| 55W| 55W| 45W| 70W| 100W| 40W
Luminous Flux| 5500lm| 5500lm| 4000lm| 6200lm| 9000lm| 4000lm
Input Voltage| 100-120V~60Hz
CCT| 6500K
CRI| ≥80
Power Factor| ≥0.9
L70B50 lifetime| 30000hours L70B50 @25°
Beam Angle| 120°
t a| -20-40°C/-4°F-104°F
Luminaire Location| SUITABLE FOR WET LOCATIONS
DIMENSIONS
Model| BDB55D-3| BDJ55D-3| BDI45D-2
Dimensions(LxHxW)
| 272x123x121mm/
10.71×4.84×4.76 in
| 270x152x109 mm/
10.63×5.98×4.29 in
| 256x140x145 mm/
10.08×5.5×5.7 in
Weight| 0.9kg/1.98 lb| 0.83kg/1.83 lb| 0.9kg/1.98 lb
Max Projected Area| 0.0214m²/0.23ft²| 0.0214m²/0.23ft²| 0.286m²/0.307ft²
Max. Lighting Coverage| 90m²/968ft²| 90m²/968ft²| 70m²/753ft²
Model| BDC80D-3| BDD100D-3| BDL40D-3
Dimensions(LxHxW)| 365x195x118 mm/14.4×7.67×4.64in| 455x182x120
mm/17.9×7.16×4.72 in| 279x136x118 mm/10.98×5.35×4.64 in
Weight| 1.2 kg/2.64 lb| 1.45 kg/3.2 lb| 0.68 kg/1.5 lb
Max Projected Area| 0.044m²/0.47ft²| 0.049m²/0.52ft²| 0.022m²/0.23ft²
Max. Lighting Coverage| 115m²/1237ft²| 160m²/1722ft²| 60m²/645ft²
Note:
The testing standard of the product’s luminous flux: Place the three/two lights on the same horizontal surface for testing, and the tested luminous flux is the accurate luminous flux.
|
- Cover
- LED Light Source
- Lamp Bracket
- Sensor head
PREPARATION
NOTE: Before beginning assembly of product, make sure all parts are
present. Compare parts with parts list. If any part is missing or damaged, do
not attempt to assemble the product.
Estimated Assembly Time:30-60 minutes.
Product appearance may vary from image shown.
Recommended to be installed on the ground above 2.5m (8.2 ft.) and no higher
than 5 m (16.4 ft.).
TOOLS REQUIRED
(not included)
WARNING:
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION
CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT
AND THE HAZARDS INVOLVED.
CAUTION:
PLEASE MAKE SURE YOUR WALL SWITCH AND POWER AT MAIN CIRCUIT BREAKER BOTH ARE
OFF.
IF IN DOUBT ABOUT ELECTRICAL INSTALLATION, CONSULT A LICENSED ELECTRICIAN.
RISK OF SHOCK:
BEFORE BEGINNING INSTALLATION,TURN OFF ELECTRICITY AT THE CIRCUIT BREAKER BOX
OR THE MAIN FUSE BOX.
NOTE:
BE SURE TO USE WIRE NUTS/CONNECTORS RATED FOR THE CORRECT GAUGE AND NUMBER OF
WIRES USED. MAKE SURE THERE ARE NO EXPOSED WIRE BUNDLES OUTSIDE THE WIRE
NUT/CONNECTOR (IF APPLICABLE). BE CAREFUL NOT TO DAMAGE OR CUT THE WIRE
INSULATION (COVERING) DURING INSTALLATION.DO NOT LET THE WIRES TOUCH ANY SHARP
EDGES.
WARNING:
DO NOT CONNECT THIS LIGHT FIXTURE TO AN UNGROUNDED ELECTRICAL SYSTEM.
ATTACH GROUND FIXTURE WIRE TO
EITHER GREEN GROUND SCREW ON MOUNTING PLATE OR THE GROUND WIRE IN THE OUTLET
BOX.
INSTALLING THIS LIGHT IN AN UNGROUNDED ELECTRICAL SYSTEM MAY CAUSE THE METAL
PARTS OF THE LIGHT TO CARRY CURRENT IF ANY WIRES OR WIRE CONNECTIONS
AREDAMAGED OR LOOSE. IN THIS CASE, ANYONE WHO TOUCHES THE LIGHT WILL RECEIVE
AN ELECTRIC SHOCK, RESULTING IN INJURY OR DEATH.
INSTALLATION STEPS
FOR WET LOCATION, MAKE SURE FILL FULL THE GAP OF EVA GASKET AND MOUNTING
SURFACE WITH SEALING COMPOUND OR SILICON GLUE.
OPERATION INSTRUCTIONS
Sensor head:
When the ambient brightness is less than 10~20LUX at night, the light will be
on automatically.
When the ambient brightness is more than 30~60LUX during the day, the light
will be off automatically.
NOTE: Do not cover the sensor head, otherwise it will affect the normal operation of the lamp.
TROUBLESHOOTING
Malfunction | Cause | Remedy |
---|---|---|
LED senses a movement, the light does not light up |
- The light is not energized
- Other surrounding light sources make the light misjudge it as daytime
|
- Check power-on status
- Turn off the nearby lights or sensor head to other directions
LED sensor light illuminates during the day| The shadows around the sensor
make it mistakenly think it’s night| Do not cover the sensor head
LED sensor light flashing|
- Surrounded by other unstable light sources shining onto the induction
- The light from the lamp itself is reflected on the sensor
|
- Avoid being exposed to such light sources
- Follow the instructions in “LED DUSK TO DAWN WALL LIGHT – Matters Needing Attention ” to readjust the light sensor
Manufacturer / Hersteller:
Shen Zhen Shi Meng Zhi Tuo Ke Ji You Xian Gong Si
Address: qian wan yi lu 1 hao A dong 201 shi qian hai shen gang he zuo qu Shen
Zhen, Guang
Dong, 518000, CN
support@onforuled.com
www.onforuleds.com
EU REP MDH LIGHTING LTD
Suite 302, 292 Strovolos Avenue, 2048 Strovolos
Nicosia, Cyprus | support@onforuled.com
UK REP MDH LIGHTING LTD
69 Aberdeen Avenue, Cambridge CB2 8DL,
United Kingdom | support@onforuled.com
Made in China
References