COMMSCOPE V4S4-360S-BF2 Small Cell 370mm Canister Antenna Instruction Manual

June 6, 2024
CommScope

COMMSCOPE V4S4-360S-BF2 Small Cell 370mm Canister Antenna

Specifications

  • Model: Metro Cell Antenna
  • Bandwidth: Wide band Compact design
  • Mounting Interface: Center 25mm diameter hole and 3pcs 8mm diameter holes on Bottom Mounting Bracket
  • Recommended Torque: 100 Nm (880 lbf-in)
  • Connector Torque: 5-8 Nm (4571 LB-IN)
  • Bracket Thickness: Recommended 6mm, range 5-7mm

Product Usage Instructions

Mounting Preparation
Before mounting the antenna, ensure the mounting surface is prepared with marked holes for installation.

Attaching RF Cables
Connect the RF cables to the antenna input connectors and torque the 4.3/10 connector to 5-8 Nm using a torque wrench.

Vertical Alignment
Use an inclinometer to verify that the antenna is truly vertical after installation.

Replacement Guidance
If replacement of the Bottom Mounting Bracket is necessary, follow the provided guidance strictly to maintain performance and safety standards.

GENERAL INFORMATION

The Metro Cell antenna (Figure 1) is a wide-band, compact antenna.
It is the responsibility of qualified personnel to determine the best method for securely anchoring the bottom mounting bracket of the antenna to the mounting surface.

INSTALLATION INSTRUCTIONS

  • When unpacking the antenna, do pay attention to port protection before placing the antenna on the ground.
  • Examine the antenna and hardware to ensure that all parts are enclosed and that there is no physical damage.
  • Verify that the frequency range shown on the label on the bottom of the antenna matches the frequency range of the station equipment.

Notice:
The designed Mounting Interface of CommScope Small Cell models is the centre 25mm diameter hole and surrounding 3pcs 8mm diameter holes on the Bottom Mounting Bracket. The Center hole serves as the mounting function, surrounding holes serve as the orientation fixing function.

Instruction Sheet

Notice:
Before mounting the bottom mounting bracket to the mounting surface, position the antenna unit so that the antenna is oriented as desired. Check Ref0 mark on bottom endcap for orientation reference. Figure 2 details the position of Ref0 mark.

  1. Refer to Figures 2, 3 and 4 for mounting and pattern alignment. It is recommended that the mounting holes be marked and made ready on the mounting surface before installing the antenna.
  2. Attach the RF cables to the antenna input connectors and torque the 4.3/10 connector to 5-8 Nm (45- 71 LB-IN), refer to Figure 5.

REPLACEMENT GUIDANCE OF BOT MTG BRACKET

Bottom Mounting Bracket Is INHERENTLY one part replacing it i customello need reeplace it. following below guidance and requirement:

  1. Do NOT replace or discard any other part except the Bottom Mounting Bracket.
  2. Keep using original M10 fasteners on antenna (they are designed for minimizing PIM impact).
  3. Customized bracket needs to have 4 mounting points (same as original bracket), mounting area should not be smaller than original bracket.
  4. Recommended bracket thickness is 6mm, thickness MUST be within range 5 – 7mm, otherwise PIM level may be influenced.
  5. Apply Loctite 425 to M10 stud and then tighten the M10 fasteners, ensure torque is well controlled with wrench, recommended torque is 30 Nm (266 LB-IN).

SAFETY NOTICE

The installation, maintenance, or removal of an antenna requires qualified, experienced personnel. CommScope installation instructions are written for such installation personnel. Antenna systems should be inspected once a year by qualified personnel to verify proper installation, maintenance, and condition of equipment.

  • CommScope disclaims any liability or responsibility for the results of improper or unsafe installation practices.
  • It is recommended that the transmit power be turned off when the field installation is performed. Follow all applicable safety precautions as shown on this page.

Do not install near power lines. Power lines, telephone lines, and guy wires look the same. Assume any wire or line can electrocute you.
Do not install on a wet or windy day or when lightning or thunder is in the area. Do not use a metal ladder.
Wear shoes with rubber soles and heels. Wear protective clothing including a long-sleeved shirt and rubber gloves.

www.commscope.com
© 2021 CommScope, Inc. All rights reserved.
Visit our website at www.commscope.com or contact your local CommScope representative or BusinessPartner for more information.
All trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of CommScope, Inc. P040-0015 A (03/21)

Frequently Asked Questions

  • Q: Can I replace the Bottom Mounting Bracket of the antenna?
    • A: While it is generally not recommended to replace the Bottom Mounting Bracket, if necessary, follow the detailed guidelines provided in the user manual to ensure proper replacement without impacting performance.
  • Q: What torque values should I use for tightening fasteners?
    • A: Torque hardware to 100 Nm (880 lbf-in) for general installation. For connector torque, use 5-8 Nm (4571 LB-IN) for the 4.3/10 connector and 30 Nm (266 LB-IN) for M10 fasteners when replacing the Bottom Mounting Bracket.
  • Q: What precautions should I take during installation?
    • A: Avoid installing near power lines, on wet or windy days, or during thunderstorms. Additionally, do not use a metal ladder during installation to prevent electrical hazards.