C-LITE C-CP-B-BRQ Series Quick Connect LED Canopy Light Instruction Manual

June 4, 2024
C-LITE

C-LITE C-CP-B-BRQ Series Quick Connect LED Canopy Light Instruction Manual
C-LITE C-CP-B-BRQ Series Quick Connect LED Canopy
Light

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should always be followed including the following:

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

  1. DANGER- Risk of shock- Disconnect power before installation.
  2. This luminaire must be installed in accordance with the NEC or your local electrical code. If you are not familiar with these codes and requirements, consult a qualified electrician.
  3. Suitable for Wet Locations.

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

FIXTURE INSTALLATION OVER RECESSED JUNCTION BOX

NOTE: Fixture is intended to be mounted over a 4″ square or 4″ or 3.5″ octagonal junction box.

  1. Remove the junction box mounting plate from the top of fixture by removing the screw from the “L” bracket and sliding the mounting plate to the side of the fixture. This will disengage the plate from the four mounting tabs on top of the fixture.

  2. Lift mounting plate away from housing and disengage plate from wireform retainer.

  3. Route supply wires from junction box through hole in mounting plate. Attach mounting plate to the junction box with (2) customer supplied screws. See Figure 1.

  4. Hang the fixture from the mounting plate by engaging the support wireform located on the top of the fixture on the retaining tab on the mounting plate. See Figure 2.

  5. Make wiring connection per the Electrical Connections section and then carefully push all wires through hole in mounting plate into junction box.

  6. Lift fixture to ceiling with wireform still engaged,. Slide housing as far away from the “L” bracket as possible.

  7. Slide fixture along ceiling towards “L” bracket, engaging the four mounting tabs.

  8. Insert screw removed in Step 1 through hole in “L” bracket and thread into hole in housing to retain housing.

  9. Same as Step 4 under “FIXTURE INSTALLATION USING SURFACE CONDUIT”.

  10. Lift the optical assembly away from the fixture housing and disconnect the two halves of the quick disconnect connector on the LED lead wires, allowing the optical assembly to be separated from the fixture housing. Set the optical assembly and screws aside.

  11. Position dip switches to select desired CCT and wattage. See Figure 3 on back page.
    NOTE: Factory setting for wattage is highest setting. Factory setting for CCT is 4000K.

  12. Replace the reflector and lens removed in Steps 9 and 10.

  13. Turn power on and confirm that fixture operates properly.

INSTALLATION

INSTALLATION INSTRUCTIONS

C-CP-B-BRQ Series

FIGURE 3

ELECTRICAL CONNECTIONS

Fixture is equipped with universal volt driver 120-277V (ie. 120V, 208V, 240V or 277V)

PHASE TO NEUTRAL WIRING 120/277V

  1. Connect supply ground to fixture ground (green) lead.
  2. Connect supply common to fixture neutral (white) lead.
  3. Connect supply Vin to fixture hot (black) lead.

Tuck all wires carefully into wiring chamber ensuring that no wires are pinched.

PHASE TO PHASE WIRING 208/240V

  1. Connect supply ground to fixture ground (green) lead.
  2. Connect supply L1 (Hot) to fixture neutral (white) lead.
  3. Connect supply L2 (Hot) to fixture hot (black) lead.

Tuck all wires carefully into wiring chamber ensuring that no wires are pinched.

DIMMING

  1. Grey or pink (-) and violet (+) leads are for 0-10V dimming systems. Cap off if not used.
    NOTE: For dimming connections, use Class 1 wiring methods only.

FIXTURE INSTALLATION USING SURFACE CONDUIT

  1. Remove the junction box mounting plate from the top of fixture by removing the screw from the “L” bracket and sliding the mounting plate to the side of the fixture. This will disengage the plate from the four mounting tabs on top of the fixture.

  2. Lift mounting plate away from housing and disengage plate from wireform retainer.

  3. Discard mounting plate.

  4. Remove the (4) screws attaching the optical assembly to the fixture housing.

  5. Lift the optical assembly away from the fixture housing and disconnect the two halves of the quick disconnect connector on the LED lead wires, allowing the optical assembly to be separated from the fixture housing. Set the optical assembly and screws aside.

  6. From the inside of the housing, pull the black, white, and green lead wires through the plug in the back of the fixture housing.

  7. Seal the (3) holes in the plug in the back of the housing with a high grade caulking material such as silicone rubber.

  8. Remove the appropriate 1/2″ plug from the side of the fixture housing and attach the surface conduit to the housing.
    NOTE: Use of Teflon tape on the conduit threads will ensure a watertight seal.

  9. Fixture is best mounted by drilling (4) holes through the back wall of the fixture housing and securing it to the mounting surface using mounting hardware appropriate for the surface. Mounting holes should be sealed with silicone rubber.

  10. Complete the wiring to the incoming power as indicated in Electrical Connections section.

  11. Hold the optical assembly close to the fixture housing and reconnect the two halves of the quick disconnect connector on the LED lead wires.

  12. Position dip switches to select desired CCT and wattage. See Figure 3.
    NOTE: Factory setting for wattage is highest setting. Factory setting for CCT is 4000K.

  13. Reattach the optical assembly to the fixture housing using the screws removed in Step 4.

FCC NOTICE

CAUTION: Changes or modifications not expressly approved could void your authority to use this equipment.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
CAN ICES-005 (A)/NMB-005 (A)

http://lighting.cree.com/warranty

1-800-236-6800

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

C-LITE User Manuals

Related Manuals