C-LITE C-WP-A-FCA Series Cutoff LED Wall Pack Instruction Manual
- June 9, 2024
- C-LITE
Table of Contents
C-WP-A-FCA Series
INSTALLATION INSTRUCTIONS
C-WP-A-FCA Series Cutoff LED Wall Pack
CAUTIONS
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be
followed including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
-
DANGER- Risk of shock- Disconnect power before installation.
DANGER – Risque de choc – Couper l’alimentation avant l’installation. -
This Product Must Be Installed In Accordance With The Applicable Installation Code By A Person Familiar With
The Construction And Operation Of The Product And The Hazards Involved. -
Min. 75°C supply conductors.
-
Suitable for wet locations.
Convient aux emplacements mouilles.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
MOUNTING OVER RECESSED JUNCTION BOX
NOTE: Knockouts are provided for mounting over 3″ octagonal, 4″ octagonal, or 4″ square junction boxes.
-
Remove lens assembly by loosening screws on side of frame. Do not loosen tamper proof screws on hinge side of frame. Swing lens assembly open,disconnect quick connect wiring connector(s) and lift lens assembly upward to remove from housing.
-
Drill out appropriate knockouts in back box for attachment to junction box. Also drill knockout for wiring access.
NOTE: Fixture should not be exclusively supported by junction box.
Drill knockouts in lower two corners and center top of back box to allow for attachment of back box to mounting surface. -
Pull supply leads from junction box through wall of back box. Attach back box to mounting surface using hardware (supplied by others) appropriate for mounting surface.
NOTE: A high grade caulking material such as silicone rubber, should be used around perimeter of back box to prevent water leakage into fixture or junction box. -
Make wiring connections per the Electrical Connections section.
-
Replace the lens assembly on hinges, re-connect quick-connect wiring connectors, and swing lens into place. Re-tighten screws that were loosened in Step 1.
WALL MOUNTED WITH CONDUIT FEED
-
Remove lens assembly by loosening screws on side of frame. Do not loosen tamper proof screws on hinge side of frame. Swing lens assembly open,disconnect quick connect wiring connector(s) and lift lens assembly upward to remove from housing.
-
Drill knockouts in lower two corners and center top of back box to allow for attachment of back box to mounting surface.
-
Attach back box to mounting surface using hardware (supplied by others) appropriate for mounting surface.
NOTE: A high grade caulking material such as silicone rubber, should be used around perimeter of back box to prevent water entry. -
Remove appropriate threaded plugs on sides of fixture and route electrical conduit to the holes desired. Feed the supply leads through the conduit and into the back box.
NOTE: Use of teflon tape on the conduit threads will ensure a watertight seal. -
Make wiring connections per the Electrical Connections section.
-
Replace the lens assembly on hinges, re-connect quick-connect wiring connectors, and swing lens into place. Re-tighten screws that were loosened in Step 1.
ELECTRICAL CONNECTIONS
Fixture is equipped with universal volt driver 120-277V (ie. 120V, 208V, 240V
or 277V)
NOTE: Make sure voltage range of fixture is compatible with supply
voltage.
PHASE TO NEUTRAL WIRING 120/277V
- Connect supply ground to fixture ground (green) lead.
- Connect supply common to fixture neutral (white) lead.
- Connect supply Vin to fixture hot (black) lead.
Tuck all wires carefully into wiring chamber ensuring that no wires are pinched.
PHASE TO PHASE WIRING 208/240V
- Connect supply ground to fixture ground (green) lead.
- Connect supply L1 (Hot) to fixture neutral (white) lead.
- Connect supply L2 (Hot) to fixture hot (black) lead.
Tuck all wires carefully into wiring chamber ensuring that no wires are pinched.
DIMMING
- Grey or pink (-) and violet (+) leads are for 0-10V dimming systems. Cap off if not used.
NOTE: For dimming connections, use Class 1 wiring methods only.
FCC NOTICE
CAUTION: Changes or modifications not expressly approved could void your
authority to use this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
CAN ICES-005 (A)/NMB-005 (A)
Document: | LPN00840X0001A0_B | Date 12-01-22 |
---|---|---|
Created By: | TMT |
http://lighting.cree.com/warranty | 1-800-236-6800
References
- Consumer Lighting Form - Cree Lighting
- LED Lighting | LED Fixtures, Bulbs & Accessories | e-conolight