oase 1000 Aquarius Universal Classic User Manual

June 13, 2024
Oase

oase logo Operating instructionsoase 1000 Aquarius Universal
Classic Aquarius Universal Classic
1000 / 12 V, 2000 / 12 V

1000 Aquarius Universal Classic

WARNING
Disconnect all electrical devices in the water from the power supply before reaching into the water. Otherwise there is a risk of severe injuries or death by electrocution.
This unit can be used by children aged 8 and above and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they are supervised or have been instructed on how to use the unit in a safe way and they understand the hazards involved. Do not allow children to play with the unit. Only allow children to carry out cleaning and user maintenance under supervision.

Safety information

Electrical connection

  • Special regulations apply for electrical installation in outdoor spaces. Only a qualified electrician may perform the electrical installation.
    – The qualified electrician has the necessary professional training, knowledge and experience to perform electrical installation in outdoor spaces. The electrician can detect potential dangers and knows how to adhere to regional and national standards, regulations and directives.
    – For your own safety, please consult a qualified electrician.

  • Only connect the unit if the electrical data of the unit and the power supply match.

  • Only plug the unit into a correctly installed outlet. Ensure that the unit is fused for a rated fault current of max. 30 mA by means of a fault current protection device.

  • Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use (splash-proof).

  • Protect open plugs and sockets from moisture.

Safe operation

  • Do not use the unit, if electrical lines or the housing are damaged.
  • Dispose of the unit if its power connection cable is damaged. The power connection cable cannot be replaced.
  • The impeller unit in the pump contains a magnet with a strong magnetic field that may affect the operation of pacemakers or implantable cardioverter defibrillators (ICDs). Keep a distance of at least 0.2 m between the implant and the magnet.
  • Do not carry or pull the unit by its power cable.
  • Route lines in such a way that they are protected from damage and do not present a tripping hazard.
  • Never carry out technical changes to the unit.
  • Only carry out work on the unit that is described in this manual.
  • Only use original spare parts and accessories.
  • Should problems occur, please contact the authorised customer service or OASE.

Intended use

Only use the product described in this manual as follows:

  • For pumping water, e.g. for water features.

  • For use in swimming ponds if the national regulations for installers are met.

  • Indoors and outdoors.

  • Only operate with original transformer.

  • While adhering to the technical specifications. (→ Technical data)

  • Adherence to the permissible water quality. (→ Permissible water quality)
    The following restrictions apply to the unit:

  • Never use the unit with fluids other than water.

  • Never run the unit without water.

  • Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.

  • Do not connect to the domestic water supply.

  • Do not use for commercial or industrial purposes.

  • According to EMC (Electromagnetic Compatibility), this is a class A unit. The unit may cause malfunctions in living environments. It is the user’s responsibility to take suitable countermeasures.

Product Description

Overviewoase 1000 Aquarius Universal Classic -
Description

  1. Inlet (suction side)
    • With filter cage (3) for submerged installation.
    • With hose sleeve for connecting a hose for dry installation.

  2. Outlet (pressure side)
    • Connection of the return line (e.g. to a fountain)

  3. Filter cage

  4. Flow rate controller

  5. Transformer with power cable
    • Pump power supply

  6. Stepped hose adapter

Symbols on the unit

| The unit is dust-tight and protected against the results of permanent immersion in water to a depth of 1 m.
---|---
IP67| The unit is dust-tight and protected against the results of temporary immersion.
| Protection class II. The unit is securely disconnected from the power supply by a reinforced or double insulation.
| Safety isolating transformer. The primary and secondary side of the transformer are galvanically isolated.
| Possible danger for persons with pacemakers.
| Protect the unit from direct sunlight.
| Protect the unit from freezing temperatures.
****| Do not dispose of the unit with normal household waste.
| Read the operating instructions.

Installation variantsoase 1000 Aquarius Universal Classic -
variants

  • Variant (a): Submerged pump installation
    – The pump is positioned in the pond or basin.
    – Water flow via the filter cage.

  • Variant (b): Dry pump installation
    – The pump is installed without the filter cage outside of the pond or basin but lower than the water level.
    – Water flow via a satellite filter or skimmer.

Installation and connection

The pump can be installed submerged (in water) or dry (outside the water).
The use of the pump is only permitted with observance of the specified water quality.
(→ Permissible water quality)
WARNING
The transformer is subject to dangerous voltage and must not be installed directly adjacent to the water. Otherwise there is a risk of severe injuries or death by electrocution.
Install the transformer at a distance of at least 2 m from the water to ensure that it is protected against flooding.
NOTE
Electrical screw connections …
must always be tightened hand-tight to ensure correct contact and so that they comply with the protection class listed in the technical data.
are protected against splash water but must not be placed or submerged in water.
NOTE
If the pump is used for conveying excessively soiled water, the impeller unit will be subject to increased wear and will require earlier replacement.
Thoroughly clean the pond or pool before installing the pump.
Install the pump at a raised level above the bottom. This reduces intake of muddy water.
Avoid direct sunlight on unit components that are not submerged, as they may overheat. If necessary, use a protective cover.
Turning the pump inlet
The pump inlet can be moved to the required orientation.

Orientation Use
Top or side (right, left) • Recommended for dry installation.

• When used with submerged installation, ensure that the water level is sufficient.
Bottom| • Recommended for submerged installation.
• Pumps water even when the water level is low.

Submerged installation of the pump

Connectingoase 1000 Aquarius Universal Classic -
Connecting Do not plug the power plug into the socket yet!
Installationoase 1000 Aquarius Universal Classic -
Installation

  • Place the pump horizontally on a stable, mud-free surface.
  • Ensure secure and stable positioning of the pump.
  • Only operate the pump when it is fully submerged.

Install the unit at a dry place

Connectingoase 1000 Aquarius Universal Classic -
place Do not plug the power plug into the socket yet!
Installationoase 1000 Aquarius Universal Classic - place
1

  • Place the pump horizontally on a stable, mud-free surface.
  • Ensure secure and stable positioning of the pump.

Commissioning/start-up

NOTE
Never connect the pump to a dimmer. Otherwise the pump will be destroyed.
NOTE
Prevent the pump from running dry. Otherwise the pump will be destroyed.
Only operate the pump when it is submerged or flooded.
Switching ON/OFF

  • Switching on: Plug the power plug into the outlet.
    – The unit switches on immediately.
    – Use the controller to set the flow rate to the desired value.

  • Switching off: Pull the power plug from the outlet.

Maintenance and cleaning

CAUTION
Risk of injury due to unexpected start-up. Internal monitoring functions may switch off the unit and automatically reactivate it.
Disconnect the power plug before carrying out any work on the unit.
NOTE
Do not use aggressive cleaning agents or chemical solutions. These agents can damage the housing, impair the function of the device and harm animals, plants and the environment.
If possible, clean the unit with clear water and a soft brush or a sponge; remove stubborn dirt with the aid of the recommended cleaning agents.
Cleaning the device
Clean the unit as required but at least twiceper year.

  • Recommended cleaning agent for removing stubborn limescale deposits:
    – Pump cleaning agent PumpClean from OASE.
    – Vinegar- and chlorine-free household cleaning agent.

  • After cleaning, thoroughly rinse all parts in clean water.

Cleaning/replacing the impeller unit

  • Dismantle the pump as shown in the figure.
  • Use a brush under clear water to clean the components.
  • Check all components for damage. Replace damaged or worn components.
  • Assemble the pump in reverse order.

oase 1000 Aquarius Universal Classic - Cleaning

Storage/winter protection

Shut down the unit at water temperatures below +4 °C or at the latest when freezing temperatures are expected.
Malfunction remedy

Malfunction Cause Remedy
Pump does not start No mains voltage Check the mains voltage.
Supply lines kinked Route the supply lines without kinks
Supply lines blocked. Check/clean the supply lines
Impeller unit is blocked Remove blockage, check impeller unit for ease of

movement
Pump does not transport fluidInsufficient flow rate| Flow rate is set too low on the controller| Increase flow rate on the controller
Filter housing clogged| Clean strainer casings
Excessive loss in the supplylines| Reduce hose length to the necessary minimum, remove
unnecessary connection parts
Impeller unit is running sluggishly| Check impeller unit for ease of movement
Pump switches off after operating
briefly| Water heavily soiled| Clean pump
Impeller unit is blocked| Remove blockage, check impeller unit for ease of movement
Pump has run dry| Check/clean the supply lines
Water temperature too high| Adhere to the maximum permissible water temperature. (→ Technical data)

Technical data

Aquarius Universal Classic 1000 / 12 V 2000 / 12 V
Connection voltage V AC 12 12
Power consump- tion Pump W 15
Pump and transfor- mer W 24 32
Max. pump capacity I/h 1000 2000
Max. pump head m 1.5 2
Protection type IP68 IP68
Max. immersion depth m 1 1
Inlet port Thread G 1/2
Connection, hose mm 13, 19, 25 13, 19, 25
Outlet port Thread G 1/2
Connection, hose mm 13, 19, 25 13, 19, 25
Filter supply surface area cm2 75 75
Water temperature (submerged install.) °C +4 … +35 +4 … +35
Ambient tempera- ture (dry installa- tion) During operation and convection
°C +4 … +30 +4 … +30
During operation and forced cooling °C +4 … +40 +4 … +40
Dimensions Length mm 125
Width mm 80 80
Height mm 75 75
Connection cable length m 10 10
Weight kg 1.4 1.4

Transformer

Primary Voltage V AC 230
Mains freq. Hz 50
Power VA 90
Cable length m 2
Secondary Voltage V AC 12
Max. power VA 70
Protection type Unit IP67
12 V connection IP44
Protection class II
Ambient temperature range °C -10…+35
Dimensions Length mm 144
Width mm 82
Height mm 80
Weight kg 1.7

Permissible water quality

Type Fresh water
pH value 6.8 … 8.5
Hardness DH 8 … 15
Free chlorine mg/l <0.3
Chloride content mg/l <250
Salt content % <0.4
Overall dry residue mg/l <50
Temperature °C +4 … +35

Wear parts

  • Impeller unit

Disposal

NOTE
Do not dispose of this unit with household waste.
  Dispose of the unit by using the return system provided for this purpose.
Should you have questions, please contact your local disposal company. They will give you information on how to correctly dispose of the unit.
Render the unit unusable by cutting the cables.

| Aquarius Universal Classic
---|---
Pos.| 1000 / 12 V| 2000 / 12 V
1| 42429| 42429
2| 26193| 26195
3| 26187| 26189
4| 26191| 26191
5| 36616| 36616

oase 1000 Aquarius Universal Classic - Cleaning 1

OASE GmbH
Tecklenburger Straße 161
48477 Hörstel | Germany
+49 (0) 5454 80-0
+49 (0) 5454 80-9353
info@oase.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals