KoolMore MDR-3GD-63C Upright Display Cooler Instruction Manual

June 4, 2024
KoolMore

KoolMore MDR-3GD-63C Upright Display Cooler

Safety And Precautions

  • DANGER
    RISK OF FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. DO NOT USEMECHANICAL DEVICES TO DEFROST REFRIGERATOR. DO NOT PUNCTURE REFRIGERANT TUBING. and DANGER – RISQUE DE FEU OU D’EXPLOSION. LE FRIGORIGÈNE EST INFLAMMABLE. NE PAS UTILISERD’APPAREILS MÉCANIQUES POUR DÉGIVRER LE RÉFRIGÉRATEUR. NE PAS PERFORER LA TUBULURECONTENANT LE FRIGORIGÈNE.
    DANGER – RISK OF FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. TO BE REPAIRED ONLY BYTRAINED SERVICE PERSONNEL. DO NOT PUNCTURE

  • REFRIGERANT TUBING. and DANGER – RISQUE DE FEU OU D’EXPLOSION. LE FRIGORIGÈNE EST INFLAMMABLE. CONFIER LESRÉPARATIONS À UN TECHNICIEN SPÉCIALISÉ. NE PAS PERFORER LA TUBULURE CONTENANT LEFRIGORIGÈNE.

  • CAUTION – RISK OF FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. CONSULT REPAIRMANUAL/OWNER’S GUIDE BEFORE ATTEMPTING TO SERVICE THIS PRODUCT. ALL SAFETYPRECAUTIONS MUST BE FOLLOWED. and ATTENTION – RISQUE DE FEU OU D’EXPLOSION. LE FRIGORIGÈNE EST INFLAMMABLE. CONSULTER LEMANUEL DU PROPRIÉTAIRE/GUIDE DE RÉPARATION AVANT DE TENTER UNE RÉPARATION. TOUTESLES MESURES DE SÉCURITÉ DOIVENT ÊTRE RESPECTÉES.

  • CAUTION – RISK OF FIRE OR EXPLOSION. DISPOSE OF PROPERLY IN ACCORDANCE WITH FEDERAL ORLOCAL REGULATIONS. FLAMMABLE REFRIGERANT USED.
    and
    ATTENTION – RISQUE DE FEU OU D’EXPLOSION. ÉLIMINER CONFORMÉMENT AUX RÈGLEMENTSFÉDÉRAUX OU LOCAUX. LE FRIGORIGÈNE EST INFLAMMABLE.

  • CAUTION – RISK OF FIRE OR EXPLOSION DUE TO PUNCTURE OF REFRIGERANT TUBING; FOLLOWHANDLING INSTRUCTIONS CAREFULLY. FLAMMABLE REFRIGERANT USED.

1. Component parts shall be replaced with like components and that servicing shall be done by factory authorized service personnel, so as to minimize the risk of possible ignition due to incorrect parts or improper service.
2. Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.
3. Do not use electrical appliances inside the food storage compartments of the appliance, unless they are of the type recommended by the manufacturer
4. Keep ventilation openings, in the appliance enclosure or in the built-in structure, clear of obstruction.

Introduction

Preface
Before you start to use the product, please read the manual carefully to fully understand the product features. Within the warranty period, the unit should be repaired, if necessary, by experienced professionals in the field of refrigeration or electrics, who provide the after-service authorized by our specific service stations. See the warranty information for more about maintenance. To continually improve the product performance, we retain the right to modify it at any time without further notice.

Purposes and Features
This product is a type of chilling cabinet, which is our new development of refrigeration combining the advanced technologies the basis of food cabinet standards and corporate criteria. With stable quality and reliable performance featuring streamlined design, the product integrates the actual market demand in structural design, which better cater to the ergonomics requirements of consumers. This series applies mainly to displaying and selling of drinks, dairy products, vegetables and fruits.

Transporting, Loading/Offloading and Accepting

  1. As some delicate articles such as glass and mirror are contained in the product and its package, please handle it gently and properly during transporting, conveying and transferring.
  2. In accepting the goods, please carefully check everything according to the attached packing list to figure out damages, if any. In case of any damage detected, please contact us through phone or email immediately, and we will respond to the situation as soon as possible.
  3. In case of any damage or loss, please identify the situation in the packing list and have the consigner acknowledge it with signature before returning it to us.

Installation

  1. The product should be place on a solid and flat floor with no gradient.
  2. The product is recommended to work with under 28℃ ambient temperature and less than 55% relative humidity, where direct sunshine and draught can be avoided. Additionally, disturbing air devices such as fan or air conditioner vent should be appear from its top or nearby.
  3.  Unobstructed ventilation should be ensured for condensing unit with ample room for repairing.
  4.  The melting water can be directed into the sewer near the product, if any, or otherwise evaporated through electric heating.

Normal operation

  1. Full-automation. Fully consider the local seasonal conditions within a year and the surrounding environment are sufficiently considered during the setting of control modules, to ensure the optimal operation of the whole full-automatic product.
  2. Normal cooling. Set the temperature controller properly according to customers’ needs to achieve both energy-saving and normal cooling. See the Appendix: Instruction of CAREL Temperature Controller for details.
  3.  Normal defrost settings. Set the timer properly for melting time and interval according to the ambient temperature and humidity, with over two melting periods for verification. See the Appendix: Instruction of CAREL Temperature Controller for details.
  4. During normal operation, the storage should not be placed beyond the shelf or block the air flow from the air curtain.

 Maintenance and Notes

  1. Cabinet cleaning. The product should be cleaned once a week with the power supply disconnected. In cleaning, please use mild rinsing water or non-corrosive cleanser essence. Do not wash it directly with a water faucet.
  2.  De-dusting for the condenser. The condenser should be cleaned every three months with the power supply disconnected. To clean the condenser, remove the left panel, and remove the dust on the cooling fin of the condenser with a wire brush or high-pressure air gun.
  3. Leaking check. Observe all connectors and welding joints for oil stains, which indicates a must for patching measures or call for professionals.
  4. Ensure the smoothness of drainpipes.
  5. Frequently observe the operation of the product. In case of any abnormal noise, smell or smog cut off the power supply immediately and call for professionals for help. Do not restart the product before trouble is cleared.
  6.  We will not be responsible for any accident incurred by failure of following the notices.

Carel Digital Temperature Controller

  1. Press the “set” button:

  2.  1s display/sets the set point

  3.  more than 3s access the parameter setting menu (enter password 22).

  4.  mutes the audible alarm(buzzer) 9.2 rapid selection of probe displayed for 1s displays firmware version
    Display”rd” set point differential “8”
    Display “co” the compressor starts over time “5”
    Display”di” interval between six defrosts”4”
    Display”C2″ the Min. compressor off time “5”
    Display”/5″,°C/°F(0=°C;1=°F) “1”

  5. Press “set” button, more than 3s, LED screen setting 2 times.

Frequent Troubleshooting

Number Troubles Causes Solutions
1 Strange noise under the

bottom shelf

| Fan blade broken.| Power off and fix the blade.



2

| ****

Non-refrigerating in spite of normal operation

| 1.    Unit off.

2.    Melting process.

3.    Refrigerant leaking

4.    Unit failure.

| 1.    Power on.

2.    Stop melting.

3.    Patch     the     leak     and     refill refrigerant.

4.    Call for professionals.



3

| ****

Weak air from air curtain, and higher cabinet temperature

| 1.    Evaporator blocked by frost.

2.    Inside fan damaged.

3. Too     low      set      point          of temperature controller.

4. Vent blocked by storage

| 1.    Increase melting frequency.

2.    Replace the fan.

3.    Adjust the set point.

4.    Remove the storage.





4

| ****



Normal air curtain,

but     higher      cabinet temperature

| 1.    Insufficient refrigerant.

2. Too     high      set     point         of temperature controllers.

3. Expansion value fails. 4.Thewind curtain disturbed by strong air flow.

5.  Ambient  temperature  or

humidity beyond standards.

| 1.    Refill the refrigerant.

2. Adjust the set point for the temperature controller.

3.       Repair or replace the expansion valve.

4.    Removing the disturbing factors.

5.    Improve the conditions.




5

| ****



Melting water overflown

| 1.             Defrost Heater for melting water damaged

2. Water-level       controller failure. 3.Ambient temperature or humidity beyond standards.

| 1.    Replace the heating pipe.

2.    Replace the water-level controller.

3.    Improve the conditions.





6

| ****



Normal air curtain, but periodical fluctuation of cabinet temperature

| 1.    Condenser contaminated.

2.    Poor venting of the unit.

3.    Heatprotection compressor    of failure.

4.        Expansion valve blocked by ice

5.    Expansion valve failure.

6.    Temperature      controller failure.

| 1.    Clean the condenser.

2.    Improve the venting conditions.

3.            Replace the heat protection.

4.            Replace the drying filter.

5.            Replace the expansion valve.

6.            Replace       the temperature controller.

Warranty

Limited Service Warranty
Valid only in the United States

1 Year Parts and Labor Warranty
Unless otherwise stated, Koolmore Supply Inc. warrants to the original purchaser of new Koolmore ice machine units, that such equipment will be free from defects in material and workmanship for a period of 1 year from the date of delivery. Valid only in the Continental United States.

Coverage Limitations

  • The 1 year parts and labor warranty do not cover:
  • Failure to install and/or use the equipment within proper operating conditions specified by Koolmore. This includes but is not limited to residential, outdoor, or mobile applications.
  • Any adjustments necessitated by improper operating conditions.
  • Improper water pressure or temperature, or failure to use and maintain a water filter, and any adjustments necessitated by these conditions. Failure to meet these conditions will void all future warranty coverage.
  • Damage caused by improper electrical connection, power failure, or generators.
  • Failure to properly maintain the unit including all preventive maintenance and cleaning.
  • Equipment sold or used outside of United States, equipment purchased second-hand, equipment sold by an unauthorized reseller, and equipment expressly sold without warranty coverage.
  • Equipment without a valid serial number and proof of purchase, or other way to verify warranty coverage.
  • Equipment that has not been used appropriately or was subject to misuse, neglect, abuse, accident, alteration, negligence, damage during transit, delivery or installation, fire, flood, or an act of God.
  • Equipment that has been altered, modified, or repaired by anyone other than an authorized service agency outside of preventative maintenance and cleaning.
  • Parts deemed by Koolmore to be normal wear and tear parts, including hoses and select plastic or rubber components.

For Warranty Inquiries or Service:
This warranty is only valid on equipment purchased from an authorized dealer.

Locate the model number.
Next, call 1-718-576-6342. You must have the model number when contacting service technicians.
Failure to contact Koolmore prior to obtaining equipment service may void your warrant

Read User Manual Online (PDF format)