AVTech COLORBAR1610IP 3x10W RGBW LED Bar Light User Manual

June 4, 2024
AVTECH

AVTech COLORBAR1610IP 3x10W RGBW LED Bar Light

AVTech-COLORBAR1610IP-3x10W-RGBW-LED-Bar-Light-product

Specifications

  • Model: COLORBAR1610 IP
  • Light Type: 3x10W RGBW LED Bar Light
  • Power Input: POWER-IN
  • DMX Input: DMX-IN
  • DMX Output: DMX-OUT
  • Power Output: POWER-OUT

Product Overview
The COLORBAR1610 IP is a versatile LED bar light designed for various lighting applications. It features RGBW LEDs that provide a wide range of colors and effects.

Features

  • DMX Control Mode
  • Programmable Settings
  • Dimmer Curves
  • Color Temperature Control
  • Strobe Functionality

Displayer Introduction
The product includes a display panel that shows important information such as DMX settings, temperature, and operational modes.

Mechanical Specification
The LED bar light has a sturdy and compact design, making it easy to mount and position for different lighting setups.

Accessory
The product may come with additional accessories for mounting or connecting to other lighting fixtures.

User Manual

Refer to the user manual for detailed instructions on setting up and operating the LED bar light.

Product Usage Instructions

  1. Connect the power input (POWER-IN) to a suitable power source.
  2. Connect the DMX input (DMX-IN) for control via DMX protocol.
  3. Use the menu buttons (MENU ENTER, UP, DOWN) to navigate settings and modes.
  4. Adjust DMX settings and channels as needed for your lighting requirements.
  5. Utilize the power output (POWER-OUT) for daisy-chaining multiple fixtures.

FAQ
How do I address the fixture using DMX-512?

To address the fixture using DMX-512:

  1. Follow the DMX 512 addressing instructions provided in the user manual.
  2. Activate ID addressing in each fixture by setting the panel function ID ON/OFF to ON.
  3. Set ID addresses in each fixture by setting the panel function ID address to incremental values (e.g., 1, 12, 24, 36, etc.).
  4. You can set up to 66 separate ID addresses for every DMX 512 starting address.
  5. Set the ID addresses in the range of 01 to 66.

USER MANUAL

Product Overview

AVTech-COLORBAR1610IP-3x10W-RGBW-LED-Bar-Light- \(2\)

Mechanical Specification

AVTech-COLORBAR1610IP-3x10W-RGBW-LED-Bar-Light- \(3\)

Packaging: Thanks for your purchasing the COLORBAR1610IP. All the lights have been checked and are in excellent operating condition. Please check the shipping carton first. Because there may be damage occurred during the shipment. Then check the lights carefully and be sure that the light is intact and works normally. In the event damage has been found, spare parts are missing or the lights work abnormally, please contact us for further instructions. And please don’t return the light to the dealer before contacting us.

Introduction:The COLORBAR1610IP has four operating modes: DMX mode, Auto mode, Master/Slave and Sound mode. And the light has seven DMX channel. DMX channel is including 3 channels, 8 channels, 12 channels, 32 channels and 37 channels. You can see 13 kinds of shows when you open the Auto mode . All then all the lights in Master/Slave mode will run following the one in Auto mode. Using fog or special effect smoke, you can see the better-showing effects.

Warning!

  1. For the sake of preventing the risk of electrical shock or fire.
  2. Don’t look directly at the opening lights all the time, or it may damage your eyes.

Features

  • Light Source: 16pcs*10W, RGBW 4 in 1 LED
  • Beam angel: 12 °
  • Power consumption: 120W
  • DMX channels: 3, 8, 12, 32, & 37 CH
  • DMX and RDM is available.
  • IR remote control included
  • Power in and out: Seetronic IP65 true 1 power input and output;
  • DMX in and out: Seetronic IP65 XLR input and output
  • Fix installation:IP65 power in and out cable.IP65 DMX in and out cable.
  • Four button with TFT LED displayer
  • Body angel: 0 to 90°
  • Fast connection between two lights in one line(Extra accessory)
  • Splicing connectors(Extra accessory)
  • Optional accessories: frost filter, barndoor,and shell frost filter for rainbow effect.
  • Bracket: Stage use-One bracket with omega lock.Fix the installation bracket on the two sides with body angle direction.
  • Temperature protection
  • Aluminum body and die-cast cover.Anti UV and salt coat painting.
  • Waterproof: IP65
  • Product dimension: 1000mm(L) 90mm(W) 113mm(H)
  • GW:5.5KG

Accessory

  1. Barndoor x 1 (purchase separate)
  2. Magnetic frost filter x 1 (purchase separately)
  3. User manual x 1
  4. Power cable x 1
  5. IR Controller x 1
  6. Fastlock x 2
  7. DMX cable x1
    AVTech-COLORBAR1610IP-3x10W-RGBW-LED-Bar-Light- \(4\)

Displayer introduction

AVTech-COLORBAR1610IP-3x10W-RGBW-LED-Bar-Light- \(5\)

  1. DMX means the light is in the DMX mode. Similarly, SLAVE means the light is in the SLAVE mode.
  2. The color of the point shows the condition of signal transmission. Green represents the good condition, while red represents the signal is interrupted.
  3. The item shows the working temperature of the light. When the working temperature exceeds the max temperature,the color of the letters and number will change from white to yellow.
  4. This item shows the menu you selected.
  5. This item shows the condition of key lock. “Key lock open” means the key lock is open.“Key lock off” means the key lock is close.

Programme Menu

AVTech-COLORBAR1610IP-3x10W-RGBW-LED-Bar-Light- \(6\) AVTech-COLORBAR1610IP-3x10W-RGBW-LED-Bar-Light-
\(7\)

DMX control mode

MODE3 CHANNELS

Channel| Value| Function
1| 000 – 255| HUE
2| 000 – 255| Saturation
3| 000 – 255| Value
MODE 8 CHANNELS

Channel| Value| Function
1| 000 – 255| Dimmer

2

| 001 – 063| Dimmer Curve1
064 – 127| Dimmer Curve2
128 – 191| Dimmer Curve3
192 – 255| Dimmer Curve4

3

| 001 – 005| No fuction
006 – 049| Dimmer speed 1
050 – 099| Dimmer speed 2
100 – 149| Dimmer speed 3
150 – 199| Dimmer speed 4
200 – 255| Dimmer speed 5
4| 000 – 255| Red
5| 000 – 255| Green
6| 000 – 255| Blue
7| 000 – 255| White
8| 000 – 255| Strobe
MODE 12 CHANNELS

Channel| Value| Function
1| 000 – 255| Dimmer

2

| 001 – 063| Dimmer Curve1
064 – 127| Dimmer Curve2
128 – 191| Dimmer Curve3
192 – 255| Dimmer Curve4

3

| 001 – 005| No fuction
006 – 049| Dimmer Curve1
050 – 099| Dimmer Curve2
100 – 149| Dimmer Curve3
150 – 199| Dimmer Curve4
200 – 255| Dimmer Curve5
4| 000 – 255| Red
5| 000 – 255| Green
6| 000 – 255| Blue
7| 000 – 255| White
8| 000 – 255| Strobe
9| 000 – 255| color
10| 000 – 255| CCT
11| 000 – 255| Auto 1-13
12| 000 – 255| speed slow -fast
MODE 32 CHANNELS

Channel| Value| Function
1| 000 – 255| Led1 Red
2| 000 – 255| Led1 Green
3| 000 – 255| Led1 Blue
4| 000 – 255| Led1 White
5| 000 – 255| Led2 Red
6| 000 – 255| Led2 Green
7| 000 – 255| Led2 Blue
8| 000 – 255| Led2 White
9-12| 000 – 255| Led3 RGBW
13-16| 000 – 255| Led4 RGBW
17-20| 000 – 255| Led5 RGBW
21-24| 000 – 255| Led6 RGBW
25-28| 000 – 255| Led7 RGBW
29-32| 000 – 255| Led8 RGBW
MODE 37 CHANNELS

Channel| Value| Function
1| 000 – 255| Dimmer

2

| 001 – 063| Dimmer Curve1
064 – 127| Dimmer Curve2
128 – 191| Dimmer Curve3
192 – 255| Dimmer Curve4

3

| 001 – 005| No fuction
006 – 049| Dimmer speed 1
050 – 099| Dimmer speed 2
100 – 149| Dimmer speed 3
150 – 199| Dimmer speed 4
200 – 255| Dimmer speed 5
4| 000 – 255| Auto 1-13
5| 000 – 255| speed slow -fast/strobe
6| 000 – 255| Led1 Red
7| 000 – 255| Led1 Green
8| 000 – 255| Led1 Blue
9| 000 – 255| Led1 White
10| 000 – 255| Led2 Red
11| 000 – 255| Led2 Green
12| 000 – 255| Led2 Blue
13| 000 – 255| Led2 White
14-17| 000 – 255| Led3 RGBW
18-21| 000 – 255| Led4 RGBW
22-25| 000 – 255| Led5 RGBW
26-29| 000 – 255| Led6 RGBW
30-33| 000 – 255| Led7 RGBW
34-37| 000 – 255| Led8 RGBW

DMX-512 addressing with ID address

  1. Follow instructions 1 for DMX 512 addressing.
  2. Activate ID addressing in each fixture by setting panel function “ID ON/OFF” to ON.
    “Settings” to “ID ON/OFF” to “ON” For every DMX 512 starting address the user can set 66 separate ID addresses. Set ID addresses in each fixture by setting panel function “ ID address” to incremental values.(l.e. 1, 12, 24, 36 etc…) “Settings” to “address” to “01~66”.

AVTech-COLORBAR1610IP-3x10W-RGBW-LED-Bar-Light- \(8\)

The figure above shows a simple DMX layout which has used three units at each DMX address. The three units have different ID addresses which allows the user to collectively control the whole group of units at that DMX address by setting Channel 10 to 0, or to control each unit independently by first selecting the DMX address and then by using Channel 11 to locate the target ID address. (Note that when using ID addresses it is also possible to activate ADAS which allows for even more option with DMX addressing and control.

UPLOAD AVTech-COLORBAR1610IP-3x10W-RGBW-LED-Bar-Light-
\(9\)

First,set one light, which involves the program you have edited in EDIT menu and want to upload, in Master mode,and others in Slave mode.
Then,connect all the lights with DMX cables.Finally,select the UPLOAD menu of the Master light and press ENTER.All the programs edited in the Master light will be uploaded to the Slave lights.

DMX MODE-In this menu,you can connect several pieces of lights with DMX cable and control
them with the control console.
Press ”ENTER” and then press “UP” or “DOWN” to ”Address” or “DMX Channel” and press “ENTER”.

  1. “XXX” will be showed in “Address”, “XXX” means the Address 001-512. You can press “UP” or “DOWN”to select the address you desired.
  2. “Channel [xx]” will be showed in “DMX Channels”, “XX” means 5 kinds of DMX Channels Modes.
    You can press “UP” or “DOWN” to select the Channel Mode you desired.

DIMMER CURVE-In this menu,you can choose the mode you desired.

  1. Press ”ENTER” and then press “UP” or “DOWN” to “Dimmer Curve” to choose as below modes.
  2. Press “ENTER” you can see 4 items as below:
  3. Standard
    Stage/TV
    Architec
    Theatre

DMX STATE-In this menu,you can choose the DMX signal you desired.

  1. Press “ENTER” and then press “UP” or “DOWN” to “DMX STATE”.
  2. Press “ENTER” and you can choose “BLACKOUT” or “DMX HOLD”;”BLACKOUT” means cut off the DMX signal and “DMX HOLD” means connect DMX signal.

SLAVE MODE-In this menu, you can choose one light as the MASTER light and other lights in SLAVE Mode will run follow the MASTER light.

  1. Press “ENTER” and then press “UP” or “DOWN” to “SLAVE Mode”.
  2. Press “ENTER” and “SLAVE” will be showed, then press “ENTER” to choose.

AUTO MODE-In this menu, you can choose your desired AUTO Mode and adjust the running speed.

  1. Press “ENTER” and then press “UP” or “DOWN” to “AUTO MODE”.
  2. Press “ENTER” you can see 2 items as below:
  3. SPEED – It provides “01-31” for you choose.
  4. AUTO MODE – It provides “AUTO 1- AUTO 13” for you choose.

STATIC COLOR-In this menu,you can choose the modes you need.

  1. Press “ENTER” and then press “UP” or “DOWN” to “AUTO MODE”.
  2. Press “ENTER” you can see 8 items as below:
  3. RED
  4. GREEN
  5. BLUE
  6. WHITE
  7. AMBER
  8. UV
  9. COLOR – You can choose “1-63” in this menu.
  10. STROBE – You can choose “0-20” in this menu.

CCT-In this menu, you can choose the brightness you desired.

  1. Press “ENTER” and then press “UP” or “DOWN” to “CCT”.
  2. Press “ENTER” you can chooose from “2700K” to “8000K” as you need.

SET UP-In this menu, you can adjust the values of the function.

  1.  Press “ENTER” and then press “UP” or “DOWN” to “SET UP”.
  2. Press “ENTER” and there has 6 options then press “ENTER” to choose the options and press “UP” or “DOWN” to choose the value you desired as below:
  3. IR – You can press “ON” or “OFF” to choose whether you need to controll by this mode.
  4. Dimmer All – You can adjust the brightness of colors.
  5. Wihte Balace – You can select “RED” “GREEN” “BLUE” “WHITE” you need.
  6. Key Lock – You can choose “ON” or “OFF” to make the Key Lock turn on or off.
  7. Display – You can choose “ON” or “30s” to make the position of the light screen.
  8.  Max temp – You can set the your desired Max working temperature of the light with passcode in this menu.When the working temperature beyond max temperature of default settings, the color of letter “Temp XX” will show the color from white to yellow.Meanwhile, the light will adjust the working temperature automatically.

INFORMATION this menu, you can learn about the information of RDM, software and hardware of the light.

  1. Press “ENTER” and then press “UP” or “DOWN” to “INFORMATION”.
  2. Press “ENTER” and you can see 3 items as below:
  3. RDM – It shows RDM information.
  4. Hardware – It shows the Hardware information.
  5. Software – It shows the Software information.

WIRELESS-In this menu,you can set the Wireless signal.

  1. Press “ENTER” and then press “UP” or “DOWN” to “WIRELESS”.
  2. Press “ENTER” and then choose “ON” or “OFF” to set the Wireless signal.”ON” is turn on the signal and “OFF” is turn off the signal.

FACTORY RESET-In this menu, you can reset all the value of the system.

  1. Press “ENTER” and then press “UP” or “DOWN” to “FACTORY RESET”.
  2. Press “ENTER” to reset all the values of the system.

Mounting

When installing the unit, the trussing or area of installation must be able to hold 10 times the weight without any deformation. When installing the unit must be secured with a secondary safety attach-ment, e.g. and appropriate safety cable. Never stand directly below the unit when mounting, removing, or servicing the unit.
Overhead mounting requires extensive experience, including calculat-ing working load limits, installation material being used, and perodic safety inspection of all installation material and unit. If you lack these qualifcations, do not attempt the installation yourself.
The installaiton should be checked by a skilled person once a year.

AVTech-COLORBAR1610IP-3x10W-RGBW-LED-Bar-Light- \(10\)

The COLORBAR1610IP is fully operational in three different mounting positions, hanging upside-down from a ceiling, set on a flat level surface or mount the unit on its side. Be sure this fxture is kept at least 0.5m away from any flammable materials (decoration etc.). And you’d better use and install the supplied safety cable as a safety measure to prevent accidental damage and/or injury in the event the clamp fails (see next page).

CABLE CONNECTORS

Cabling must have a male XLR connector on one end and a female XLR connector on the other end.
DMX connector configuration

AVTech-COLORBAR1610IP-3x10W-RGBW-LED-Bar-Light- \(11\)

caution:Do not allow contact between the ground and the fixture’s chassis ground. Grounding the ground can cause a ground loop, and your fixture may perform erratically. Test cables with an ohm meter to verify positive pole and to make sure the pins are not grounded or shorted to the shield or each other.

3-PIN TO 5-PIN CONVERSION CHART
Note! If you use a controller with a 5 pin DMX output connector, you need to use a 5 pin to 3 pin adapter. The chart below details a proper cable conversion:

3-PIN TO 5-PIN CONVERSION CHART

Conductor 3 Pin Female (output) 5 Pin Male (Input)
Ground/Shield Pin 1 Pin 1
Data ( – ) signal Pin 2 Pin 2
Data ( + ) signal Pin 3 Pin 3
Do not use Do not use
Do not use Do not use

IR Controller

AVTech-COLORBAR1610IP-3x10W-RGBW-LED-Bar-Light- \(14\)

RDM—Remote Device Management

RDM is a wild version of the DMX512-A protocol, allowing dimming stations and other control devices to be discovered through a DMX512 network, and then configuring, status monitoring, and managing intermediate and line end devices.
It allows two-way communication between the lighting device or system controller and the connected RDM compatible device through the standard DMX. This protocol will allow these devices to be configured, monitored, and managed in a manner that does not interfere with the normal operation of standard DMX512 devices that do not recognize the RDM protocol.
Allow a controller or test device to find other devices that can be RDM, such as computer lights or dimming cabinets, and remotely manage them through this connection intelligence. Including the ability to remotely set the initial address of the DMX512, query the device’s errors or statistics, and achieve most of the configuration settings that are usually done on the front panel of the device. RDM can run with the new RDM device or any original DMX512 product on the same data link without any performance impact. Since RDM runs on the first team DMX512 link, the only infrastructure upgrade required by RDM is to upgrade the existing data distributor to implement a two-way mode to support RDM.

The RDM information is transmitted through the first pair of DMX512 data channels. RDM uses packets that include non-zero initial codes to start and control communications. This alternating(rotating) session and waiting for indicative responses is performed in a semi-duplex format. The second data pair is not used for any RDM function.
Two-way data transmission vendor’s equipment can exchange data, Art-net can only transmit data, can not exchange with each other.

Its functions are as follows:

AVTech-COLORBAR1610IP-3x10W-RGBW-LED-Bar-Light- \(1\)

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals