Specifications
- Product Name: LEDWALL40 25IP
- Power: 40x25W
- Light Type: RGBW LED Wash Light
Product Usage Instructions
Safety Warning Instructions
It is important to follow these safety precautions:
-
Check for damages caused by transportation upon receiving the
lights. -
Always disconnect the power before installation, cleaning, and
maintenance.
Installation
Follow these guidelines for proper installation:
-
Use clamps only for installing fixtures, not as handles.
-
Securely attach a safety rope through the safety hole of the
fixture body. -
Avoid side hanging the fixtures.
Signal and Power Connection
For signal and power connection:
-
Use a 3-pin signal cable to connect multiple fixtures, with a
maximum of 32 fixtures. -
Power each fixture separately with matching voltage and
frequency as specified in the manual.
Function Setting
To access the function settings:
- Power-on password: UP – DOWN – UP – DOWN – ENTER
- Browse through setup options using UP or DOWN buttons.
- Press ENTER to save settings or move to the next menu.
DMX Address Setting
To set the DMX address:
- Ensure proper signal connection between fixtures.
- Select master-slave synchronization control if needed.
FAQ
Q: What should I do if I notice damages caused by
transportation?
A: Contact your dealer or manufacturer immediately and refrain
from using the device.
Q: How do I connect multiple fixtures for DMX operation?
A: Use a 3-pin signal cable to connect up to 32 fixtures in
series.
Q: How can I access the function settings of the device?
A: Use the power-on password UP – DOWN – UP – DOWN – ENTER and
navigate through settings using the UP and DOWN buttons.
“`
LEDWALL40 25IP
40x25W RGBW LED Wash Light
This product manual contains important information about the safe installation
and use of the light. Please read and follow these instructions carefully and
keep this manual in a safe place for future reference.
2/14
Content
Safety warning instructions
3
Installation
4
Signal and power connection
5
Function setting
6
DMX address setting
6
Operation menu
7
DMX Channel
9
Maintenance
12
Trouble shooting
12
Technical data
13
Every unit is tested completely and packed properly by the manufacturer.
Please make sure the packing and / or the unit are in good condition before
installation and use. Should there be any damage caused by transportation,
consult your dealer and do not use the unit. Any damage caused by improper use
will not be assumed by the manufacturer and / or dealer.
Please note that as part of our ongoing commitment to continuous product
development, specifications are subject to change without notice.
ACCESSAORIES
The follwing items have packed with the light,please pay atteneion to check
Name
Quantity
Unit
Clamps
1
PCS
Safety Cord
1
PCS
Instructions
1
PCS
Remark
3/14
Safety warning information
After receiving the lights, please open to check whether there is any damages
caused by transportation. In case of damages caused of transportation, please
don’t this device and contact your dealer or manufacturer as soon as possible.
The projector is for indoor and outdoor use, IP65. Do not install the fixtures
onto inflammable surfaces directly. The fixture is only intended for
installation, operation and maintenance by qualified personnel. Do not project
the beam onto inflammable surfaces, minimum distance is 3 meter. 3m Avoid
direct exposure to the light from the lamp. The light is harmful to the eyes.
Do not attempt to dismantle and/or modify the projector in any way. Electrical
connection must only be carried out by qualified personnel. Before
installation, ensure that the voltage and frequency of power supply match the
power requirements of the fixture. It is essential that each projector is
correctly earthed and that electrical installation conforms to all relevant
standards. Do not connect this device to any other types of dimmer apparatus.
The projector should always be installed with a secondary safety fixing. A
safety cord is supplied for this; it should be attached as shown in
“installing the projector” section. Shields and lens shall be changed if they
have become visibly damaged to such an extent than their effectiveness is
impaired, for example by cracks or deep scratches. Exterior surface
temperatures of the luminaire after 5 minutes operation is 45, when steady
state is achieved 70. There is no user serviceable parts inside the projector,
do not open the housing and never operate the fixture with the covers removed.
There is no user serviceable parts inside this light, please check whether all
covers or shells have been installated and screws have beed tightened
securely. It is forbidden to use lights with covers(or shell) open. If you
have any questions, don’t hesitate to consult your dealer or manufacturer.
4/14
Always disconnection from Power before the device’s installation, cleaning and
maintenance
Installation
Take out 2 clamps and 1 safety rope, install the 2 clamps on the bottom of the
fixture with the 4 quick knob attached to the clamps , then hang the fixture
on the fixed support with the clamp, and tighten the clamp lock bolt to fix
the fixture. Please confirm that the fixture installation is stable and
reliable, and ensure that the hoisting position has sufficient strength to
withstand the weight of the fixture. please carry the randomly equipped safety
rope through the bottom of the fixture holder for auxiliary hoisting to ensure
safety.
Warn 1The clamps are only used when install the fixtures. It is strictly
forbidden to use the clamps as a handle to carry
the fixtures.
2For safety reasons, please use a safety rope that can withstand 10 times the
weight of the fixture through the
safety hole of the fixture body.
3Side hang the fixtures are forbidden .
Signal and power connect
5/14
DMX OUT
2
1
3
DMX IN
1
2
3
DMX 512
PIN FUNCTION
1
GND
2
DATA-
3
DATA+
For the connection of control signals, 2-pin shielded cables with a diameter
not less than 0.5 mm must be used between the fixture and the controller and
between the fixtures. Please use the 3-pin signal output / incoming line of
the lamp to connect. The connections between the 3-pin signal line ports are
shown in the figure above. It must be noted that the 3 pin of the XLR plug /
socket must not be in contact with the inner shell or between the cores when
connecting. The XLR plug / socket and the XLR control cable cannot be
connected in any other way than the connection shown in the figure above. This
product receives the international standard DMX512 (1990) control signal.
The signal connection of multiple fixtures, the maximum number of connection
is 32 fixtures, use a 3-pin signal cable from the DMX output port of the
controller to the DMX input line of the 1st fixture, and connect from the DMX
output line of the first fixture To the DMX input line of the second fixture,
and so on, until all the fixtures are connected.
When the first fixture is not connected to the controller (the signal line
connection between the other fixtures remain unchanged), it is the connection
mode of master-slave synchronous control. However, to achieve masterslave
synchronization control, the first fixture should be set as the master in the
menu, and the remaining fixtures should be set as slaves (the default value is
slave).
When connecting the power supply, the power supply of each fixture should be
connected separately. Please note that the power supply voltage and frequency
must match with the power supply voltage and frequency listed in the product
manual.
6/14
Function and installation
power-on password: UP – DOWN- UP – DOWN- ENTER Press button UP or DOWN if you
want to browse through the various Setup Options. Press button ENTER to save
your settings or enter the next menu. Press button UP or DOWN to shift. Press
button Menu will return to the upper menu one by one.
DMX address setting
When using the controller to control multiple fixtureseach fixture shall be
provided with a DMX address to receive signals from the controller and respond
correctly, There are 3 control modes in this product, which are simple mode,
standard mode and extent mode.
For example: The fixture has 20 channels at standard mode. We set the 1st
fixture :DMX Address 001, then the 2nd fixture DMX Address 021the 3rd fixture
DMX Address 041the 4th fixture 61… …and so on. Turn on the fixtureIf operating
menu is lockedpress ENTER for 5 Sec, the fixture will be unlocked Then press
Menu or UP or DOWN to find AddR menu Press ENTER display DMX Address Press UP
/ DOWN set DMX Address value Press ENTER to confirmthen the fixture
automatically saved this DMX address Press Menu will return to the upper menu
7/14
Level 1 DMX address DMX channel mode
DMXS DMX setting PAIR Dimmer curve
Frequency (HZ)
Manual color
Auto program Language Display
Factory settings System information
Operation menu
1-512
Level 2
Cancel
Enter
4 channel mode 1
10 channel mode 2
37 channel mode
ONCA (Only XLR) ONWR (Only wireless)
PPCA (XLR first) PRWR (wireless first) WTOC (wireless to XLR)
yes
no
Dimmer curve 1
Dimmer curve 2
Dimmer curve 3
Dimmer curve 4
A
B
C
D
Y axis
Red
Green
Blue
White
Auto color
Aoto fade
English
Chinese
Normal
Reverse
Red
Green
Blue
W
No
Yes
RDM UID
Version
8/14
Level 3
0-255 0-255 0-255 0-255 0-255 0-255 0-255
DMX channel Run time Use time Temperature Remarks 1 Only one fixture can be
set to host in one signal line, remove DMX control signal when using host
function 2. In the synchronous control of multiple fixtures parameters can be
transmitted from the master including: DMX mode, display setting, operation
mode (user memory data included); All fixtures accepting parameters will
automatically be set to slave mode.
9/14
4 Channel
Channel Name
1
Red
2
Green
3
Blue
4
White
DMX
DMX Value
0-255(65535) 0-255(65535) 0-255(65535) 0-255(65535)
DMX Percentage
0-100% 0-100% 0-100% 0-100%
Description
0-100% R 0-100% G 0-100% B 0-100% W
10 Channel ( CTC)
Channel Name
DMX Value DMX Percentage Description
1
Dimmer
0-255
0-100%
0-100%Intensity
2
Shutter
0-7
0-2.7%
Closed
8-15
3.1%-5.9%
Open
16-151
6.3%-59.2%
Variable Strobe
152-175
59.6%-68.6%
Pulse-Open
176-199
69%-78%
Pulse- Closed
200-244
78.4%-95.7%
Variable Random Strobe
245-255
96.1%-100%
Shutter Open
3
Macro
0-255
0-100%
0-100%Intensity
4
Macro Speed 0-255
0-100%
0-100%Intensity
5
Macro Color 0-255
0-100%
0-100%Intensity
6
Red
0-255
0-100%
0-100% R
7
Green
0-255
0-100%
0-100% G
8
Blue
0-255
0-100%
0-100% B
9
White
0-255
0-100%
0-100% W
10
CTC
0
0
5600K
1-4
0.4%-1.6%
RAW
5-255
2%-100%
White CTC 2000-10000K
37 Channel
Channel Name
DMX Value DMX Percentage Description
1
Dimmer
0-255
0-100%
0-100%Intensity
2
Shutter
0-7 8-15 16-151 152-175 176-199
0-2.7% 3.1%-5.9% 6.3%-59.2% 59.6%-68.6% 69%-78%
Closed Open Variable Strobe Pulse-Open Pulse- Closed
10/14
200-244
78.4%-95.7%
Variable Random Strobe
245-255
96.1%-100%
Shutter Open
3
Macro
0-255
0-100%
0-100%Intensity
4
Macro Speed 0-255
0-100%
0-100%Intensity
5
Macro Color 0-255
0-100%
0-100%Intensity
6
Red1
0-255
0-100%
0-100% R
7
Green1
0-255
0-100%
0-100% G
8
Blue1
0-255
0-100%
0-100% B
9
White1
0-255
0-100%
0-100% W
…..
…….
……..
34
Red 8
0-255
0-100%
0-100% R
35
Green 8
0-255
0-100%
0-100% G
36
Blue 8
0-255
0-100%
0-100% B
37
White 8
0-255
0-100%
0-100% W
Channel priority: dimming> built-in program call > user program call>ARGBW dimming >HSV dimming> Macro Instruction> Color Temperature
Maintenance
11/14
To ensure the reliability of the projector it should be kept clean. It is
recommended that the fans should be cleaned every 15 days. The lens and
dichroic color filters should also be regularly cleaned to maintain an optimum
light output. Do NOT use any type of solvent on dichroic color filters.
Cleaning frequency depends on the environment in which the fixture operates:
damp, smoke or particularly dirty surroundings can cause greater accumulation
of dirt on the unit’s optics. A soft cloth and typical glass cleaning products
should be used in cleaning. It is recommended to clean the external optics at
least once every 20 days and clean the internal optics at least once every 30
/ 60 days.
Do not use any organic solvent, e.g. alcohol, to clean the reflector mirror, dichroic color filters or housing of the apparatus.
Trouble shooting
Problems
Action
power cord connection is not normal the switching power supply is damaged or the connection is not
The fixture wont switch on properly
normal, professional qualified technician needed to carry out
maintenance and repair control board connection is not normalprofessional
qualified
technician needed to carry out maintenance and repair
The fixture switch onbut LED not LED board connection is not normal professional qualified
bright and not controlled
technician needed to carry out maintenance and repair
Switch on and light normallybut not check the DMX starting address code setting is correct or not
controlled by controller
Check the XLR signal line is damaged or not
The fixture is dim and the brightness The fixtures temperature is too high, please take necessary
drops sharply
ventilation and heat dissipation measures
Technical data
12/14
Input voltage
AC 100V/120V/200V/220V /230V/240V 50/60Hz
Power
600W@220V
LED light source
Working lifetime
40PCS 25W RGBW 50000h
Dimmer
0-100% linear dimming
Strobe
Electric strobe0.3-20pcs/sec Max 20 Hz
Control mode
International standard DMX 512signal3 Pin (5 Pin) DMX512 interface Wireless
2.4 GHz W-DMXTM (optional) 3 channel modes Master-slave
Stand-alone mode Self-test mode
RDM
Other functions
Adjustable horizontal and vertical speed Display fixture using time Display
software version number Modular structure for easy maintenance Speed-
regulating radiator
Shell and protection level
High-strength casting aluminum alloyIP65 black shellwhite optional
Working temperature
-20°C40°C
Weight
14.8Kg
Produce size
See below
13/14