AVTech LEDWALL4025IP 40x25W RGBW LED Wash Light Instruction Manual

June 1, 2024
AVTECH

LEDWALL4025IP 40x25W RGBW LED Wash Light

“`html

Specifications

  • Product Name: LEDWALL40 25IP
  • Power: 40x25W
  • Light Type: RGBW LED Wash Light

Product Usage Instructions

Safety Warning Instructions

It is important to follow these safety precautions:

  • Check for damages caused by transportation upon receiving the
    lights.

  • Always disconnect the power before installation, cleaning, and
    maintenance.

Installation

Follow these guidelines for proper installation:

  • Use clamps only for installing fixtures, not as handles.

  • Securely attach a safety rope through the safety hole of the
    fixture body.

  • Avoid side hanging the fixtures.

Signal and Power Connection

For signal and power connection:

  • Use a 3-pin signal cable to connect multiple fixtures, with a
    maximum of 32 fixtures.

  • Power each fixture separately with matching voltage and
    frequency as specified in the manual.

Function Setting

To access the function settings:

  • Power-on password: UP – DOWN – UP – DOWN – ENTER
  • Browse through setup options using UP or DOWN buttons.
  • Press ENTER to save settings or move to the next menu.

DMX Address Setting

To set the DMX address:

  1. Ensure proper signal connection between fixtures.
  2. Select master-slave synchronization control if needed.

FAQ

Q: What should I do if I notice damages caused by

transportation?

A: Contact your dealer or manufacturer immediately and refrain
from using the device.

Q: How do I connect multiple fixtures for DMX operation?

A: Use a 3-pin signal cable to connect up to 32 fixtures in
series.

Q: How can I access the function settings of the device?

A: Use the power-on password UP – DOWN – UP – DOWN – ENTER and
navigate through settings using the UP and DOWN buttons.

“`

LEDWALL40 25IP
40x25W RGBW LED Wash Light
This product manual contains important information about the safe installation and use of the light. Please read and follow these instructions carefully and keep this manual in a safe place for future reference.

2/14

Content

Safety warning instructions

3

Installation

4

Signal and power connection

5

Function setting

6

DMX address setting

6

Operation menu

7

DMX Channel

9

Maintenance

12

Trouble shooting

12

Technical data

13

Every unit is tested completely and packed properly by the manufacturer. Please make sure the packing and / or the unit are in good condition before installation and use. Should there be any damage caused by transportation, consult your dealer and do not use the unit. Any damage caused by improper use will not be assumed by the manufacturer and / or dealer.
Please note that as part of our ongoing commitment to continuous product development, specifications are subject to change without notice.

ACCESSAORIES

The follwing items have packed with the light,please pay atteneion to check

Name

Quantity

Unit

Clamps

1

PCS

Safety Cord

1

PCS

Instructions

1

PCS

Remark

3/14

Safety warning information
After receiving the lights, please open to check whether there is any damages caused by transportation. In case of damages caused of transportation, please don’t this device and contact your dealer or manufacturer as soon as possible.
The projector is for indoor and outdoor use, IP65. Do not install the fixtures onto inflammable surfaces directly. The fixture is only intended for installation, operation and maintenance by qualified personnel. Do not project the beam onto inflammable surfaces, minimum distance is 3 meter. 3m Avoid direct exposure to the light from the lamp. The light is harmful to the eyes. Do not attempt to dismantle and/or modify the projector in any way. Electrical connection must only be carried out by qualified personnel. Before installation, ensure that the voltage and frequency of power supply match the power requirements of the fixture. It is essential that each projector is correctly earthed and that electrical installation conforms to all relevant standards. Do not connect this device to any other types of dimmer apparatus. The projector should always be installed with a secondary safety fixing. A safety cord is supplied for this; it should be attached as shown in “installing the projector” section. Shields and lens shall be changed if they have become visibly damaged to such an extent than their effectiveness is impaired, for example by cracks or deep scratches. Exterior surface temperatures of the luminaire after 5 minutes operation is 45, when steady state is achieved 70. There is no user serviceable parts inside the projector, do not open the housing and never operate the fixture with the covers removed. There is no user serviceable parts inside this light, please check whether all covers or shells have been installated and screws have beed tightened securely. It is forbidden to use lights with covers(or shell) open. If you have any questions, don’t hesitate to consult your dealer or manufacturer.
4/14

Always disconnection from Power before the device’s installation, cleaning and maintenance
Installation
Take out 2 clamps and 1 safety rope, install the 2 clamps on the bottom of the fixture with the 4 quick knob attached to the clamps , then hang the fixture on the fixed support with the clamp, and tighten the clamp lock bolt to fix the fixture. Please confirm that the fixture installation is stable and reliable, and ensure that the hoisting position has sufficient strength to withstand the weight of the fixture. please carry the randomly equipped safety rope through the bottom of the fixture holder for auxiliary hoisting to ensure safety.
Warn 1The clamps are only used when install the fixtures. It is strictly forbidden to use the clamps as a handle to carry
the fixtures.
2For safety reasons, please use a safety rope that can withstand 10 times the weight of the fixture through the
safety hole of the fixture body.
3Side hang the fixtures are forbidden .
Signal and power connect
5/14

DMX OUT

2

1

3

DMX IN

1

2

3

DMX 512

PIN FUNCTION

1

GND

2

DATA-

3

DATA+

For the connection of control signals, 2-pin shielded cables with a diameter not less than 0.5 mm must be used between the fixture and the controller and between the fixtures. Please use the 3-pin signal output / incoming line of the lamp to connect. The connections between the 3-pin signal line ports are shown in the figure above. It must be noted that the 3 pin of the XLR plug / socket must not be in contact with the inner shell or between the cores when connecting. The XLR plug / socket and the XLR control cable cannot be connected in any other way than the connection shown in the figure above. This product receives the international standard DMX512 (1990) control signal.
The signal connection of multiple fixtures, the maximum number of connection is 32 fixtures, use a 3-pin signal cable from the DMX output port of the controller to the DMX input line of the 1st fixture, and connect from the DMX output line of the first fixture To the DMX input line of the second fixture, and so on, until all the fixtures are connected.
When the first fixture is not connected to the controller (the signal line connection between the other fixtures remain unchanged), it is the connection mode of master-slave synchronous control. However, to achieve masterslave synchronization control, the first fixture should be set as the master in the menu, and the remaining fixtures should be set as slaves (the default value is slave).
When connecting the power supply, the power supply of each fixture should be connected separately. Please note that the power supply voltage and frequency must match with the power supply voltage and frequency listed in the product manual.

6/14

Function and installation
power-on password: UP – DOWN- UP – DOWN- ENTER Press button UP or DOWN if you want to browse through the various Setup Options. Press button ENTER to save your settings or enter the next menu. Press button UP or DOWN to shift. Press button Menu will return to the upper menu one by one.
DMX address setting
When using the controller to control multiple fixtureseach fixture shall be provided with a DMX address to receive signals from the controller and respond correctly, There are 3 control modes in this product, which are simple mode, standard mode and extent mode.
For example: The fixture has 20 channels at standard mode. We set the 1st fixture :DMX Address 001, then the 2nd fixture DMX Address 021the 3rd fixture DMX Address 041the 4th fixture 61… …and so on. Turn on the fixtureIf operating menu is lockedpress ENTER for 5 Sec, the fixture will be unlocked Then press Menu or UP or DOWN to find AddR menu Press ENTER display DMX Address Press UP / DOWN set DMX Address value Press ENTER to confirmthen the fixture automatically saved this DMX address Press Menu will return to the upper menu
7/14

Level 1 DMX address DMX channel mode
DMXS DMX setting PAIR Dimmer curve
Frequency (HZ)
Manual color
Auto program Language Display
Factory settings System information

Operation menu

1-512

Level 2

Cancel

Enter

4 channel mode 1

10 channel mode 2

37 channel mode
ONCA (Only XLR) ONWR (Only wireless)
PPCA (XLR first) PRWR (wireless first) WTOC (wireless to XLR)
yes

no

Dimmer curve 1

Dimmer curve 2

Dimmer curve 3

Dimmer curve 4

A

B

C

D

Y axis

Red

Green

Blue

White

Auto color

Aoto fade

English

Chinese

Normal

Reverse

Red

Green

Blue

W

No

Yes

RDM UID

Version

8/14

Level 3
0-255 0-255 0-255 0-255 0-255 0-255 0-255

DMX channel Run time Use time Temperature Remarks 1 Only one fixture can be set to host in one signal line, remove DMX control signal when using host function 2. In the synchronous control of multiple fixtures parameters can be transmitted from the master including: DMX mode, display setting, operation mode (user memory data included); All fixtures accepting parameters will automatically be set to slave mode.
9/14

4 Channel

Channel Name

1

Red

2

Green

3

Blue

4

White

DMX

DMX Value
0-255(65535) 0-255(65535) 0-255(65535) 0-255(65535)

DMX Percentage
0-100% 0-100% 0-100% 0-100%

Description
0-100% R 0-100% G 0-100% B 0-100% W

10 Channel ( CTC)

Channel Name

DMX Value DMX Percentage Description

1

Dimmer

0-255

0-100%

0-100%Intensity

2

Shutter

0-7

0-2.7%

Closed

8-15

3.1%-5.9%

Open

16-151

6.3%-59.2%

Variable Strobe

152-175

59.6%-68.6%

Pulse-Open

176-199

69%-78%

Pulse- Closed

200-244

78.4%-95.7%

Variable Random Strobe

245-255

96.1%-100%

Shutter Open

3

Macro

0-255

0-100%

0-100%Intensity

4

Macro Speed 0-255

0-100%

0-100%Intensity

5

Macro Color 0-255

0-100%

0-100%Intensity

6

Red

0-255

0-100%

0-100% R

7

Green

0-255

0-100%

0-100% G

8

Blue

0-255

0-100%

0-100% B

9

White

0-255

0-100%

0-100% W

10

CTC

0

0

5600K

1-4

0.4%-1.6%

RAW

5-255

2%-100%

White CTC 2000-10000K

37 Channel

Channel Name

DMX Value DMX Percentage Description

1

Dimmer

0-255

0-100%

0-100%Intensity

2

Shutter

0-7 8-15 16-151 152-175 176-199

0-2.7% 3.1%-5.9% 6.3%-59.2% 59.6%-68.6% 69%-78%

Closed Open Variable Strobe Pulse-Open Pulse- Closed

10/14

200-244

78.4%-95.7%

Variable Random Strobe

245-255

96.1%-100%

Shutter Open

3

Macro

0-255

0-100%

0-100%Intensity

4

Macro Speed 0-255

0-100%

0-100%Intensity

5

Macro Color 0-255

0-100%

0-100%Intensity

6

Red1

0-255

0-100%

0-100% R

7

Green1

0-255

0-100%

0-100% G

8

Blue1

0-255

0-100%

0-100% B

9

White1

0-255

0-100%

0-100% W

…..

…….

……..

34

Red 8

0-255

0-100%

0-100% R

35

Green 8

0-255

0-100%

0-100% G

36

Blue 8

0-255

0-100%

0-100% B

37

White 8

0-255

0-100%

0-100% W

Channel priority: dimming> built-in program call > user program call>ARGBW dimming >HSV dimming> Macro Instruction> Color Temperature

Maintenance
11/14

To ensure the reliability of the projector it should be kept clean. It is recommended that the fans should be cleaned every 15 days. The lens and dichroic color filters should also be regularly cleaned to maintain an optimum light output. Do NOT use any type of solvent on dichroic color filters.
Cleaning frequency depends on the environment in which the fixture operates: damp, smoke or particularly dirty surroundings can cause greater accumulation of dirt on the unit’s optics. A soft cloth and typical glass cleaning products should be used in cleaning. It is recommended to clean the external optics at least once every 20 days and clean the internal optics at least once every 30 / 60 days.

Do not use any organic solvent, e.g. alcohol, to clean the reflector mirror, dichroic color filters or housing of the apparatus.

Trouble shooting

Problems

Action

power cord connection is not normal the switching power supply is damaged or the connection is not

The fixture wont switch on properly

normal, professional qualified technician needed to carry out
maintenance and repair control board connection is not normalprofessional qualified

technician needed to carry out maintenance and repair

The fixture switch onbut LED not LED board connection is not normal professional qualified

bright and not controlled

technician needed to carry out maintenance and repair

Switch on and light normallybut not check the DMX starting address code setting is correct or not

controlled by controller

Check the XLR signal line is damaged or not

The fixture is dim and the brightness The fixtures temperature is too high, please take necessary

drops sharply

ventilation and heat dissipation measures

Technical data
12/14

Input voltage
AC 100V/120V/200V/220V /230V/240V 50/60Hz

Power
600W@220V

LED light source
Working lifetime

40PCS 25W RGBW 50000h

Dimmer
0-100% linear dimming

Strobe
Electric strobe0.3-20pcs/sec Max 20 Hz

Control mode
International standard DMX 512signal3 Pin (5 Pin) DMX512 interface Wireless 2.4 GHz W-DMXTM (optional) 3 channel modes Master-slave
Stand-alone mode Self-test mode

RDM

Other functions
Adjustable horizontal and vertical speed Display fixture using time Display software version number Modular structure for easy maintenance Speed- regulating radiator

Shell and protection level
High-strength casting aluminum alloyIP65 black shellwhite optional
Working temperature
-20°C40°C

Weight
14.8Kg

Produce size
See below

13/14

14/14

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals