AVTech HYBRID18R 370W 3 In 1 LED Moving Head User Manual

June 4, 2024
AVTECH

HYBRID18R 370W 3 In 1 LED Moving Head

HYBRID18R

370W 3in1 LED Moving Head

USER MANUAL

Warning

Before using this product, Please read the instructions carefully.

Please keep this instruction, As a basis for future advice, If you sell this product to other  users, Please make sure they also get this manual.

Please use it correctly on the basis of understanding the content.

Note :

The equipment is well packed when it leaves the factory, Please follow the user Manual to operate, human causes of machine failure is not covered by warranty.

⬥ Before using the product, Please open and check carefully to ensure that the lamps are not damaged by transportation.

⬥ The lamp is suitable for indoor drying only.

⬥ Installation and operation of lamps and lanterns should be carried out by professionals.

⬥ Don’t let children operate machines.

⬥ Use a safety cord when fixing equipment, lift the bottom while moving the lamp.

⬥ Equipment must be installed in good ventilation at least 50 cm from adjacent plane.

⬥ Make sure the ventilation hole is unobstructed so as not to overheat the lamp during operation.

⬥ Ensure that the power supply voltage is in line with the required power supply voltage before operation.

⬥ Please ground the conductive body to prevent electric shock.

⬥ Ambient temperature: do not run lamps below-25℃ or above 45℃.

⬥ It is forbidden to connect lamps directly to dimming equipment.

⬥ Do not place combustible items within 1 meter next to the lamp to prevent fire.

⬥ Please check carefully whether the power cord is damaged before opening the lamp. If there is any damage, please replace it immediately.

⬥ Lamp operation surface temperature can reach 55℃, do not touch with bare hands.

⬥ Avoid flammable liquids, water or metal conductors entering the interior of the lamp to avoid electric shock or fire.If any foreign body enters the lamp, please cut off the power  immediately.

⬥ Avoid operating in dirty, dusty environment, and regularly clean and maintain lamps.

⬥ Do not touch the wire when the lamp is running to prevent electric shock.

⬥ Avoid winding power cord with other wire.

⬥ Distance between lamp and irradiation surface is greater than 15 M.

⬥ Disconnect the power before replacing the fuse or bulb.

⬥ Use the same model to replace fuse or bulb.

⬥ Serious Operation Failure Occurred,please stop using it immediately.

⬥ Do not repeat opening.

⬥ Please replace the case, lens or UV filter visible damage.

⬥ No spare parts inside the lamp, do not open the lamp shell without authorization.

⬥ Do not operate the machine on your own, non-professional operation will cause damage to the equipment or functional failure, For maintenance, please contact the nearest authorized service center.

⬥ Please cut off the power supply when the lamp is not used or repaired for a long time.

⬥ For re-transportation, please use the original package.

⬥ To avoid fire or electric shock, do not expose lamps to rain or wet areas.

⬥ High temperature light bulb is in danger of explosion, do not turn on the lamp within 15 minutes of  power failure.

⬥ Light bulb damage, thermal deformation or beyond service life please replace in time.

⬥ Do not look directly at the lamp in operation.

⬥ Do not look directly at the lamp in operation.

⬥ The plug must be grounded in operation.

⬥ Do not operate the machine when the lamp has no shield or shell damage.

2. Technical specifications

Source:
10~240,50/60Hz
Power:
530W(90V)
Lamp bulb:
OSRAM SIRIUS HRI 371W.(Light bulb rated life:≥1500H)
Colour temperature :8000K
Power off display function :
Connect the USB socket when power is off you can enter the menu to set the address code
and other settings.
Optical system:
Efficient optical systems
Strong Optical Output
High quality optical lens
Mobile:
Level:540°.
Vertical:270°.
The speed of horizontal / vertical movement can be adjusted.
Automatic completion of horizontal/vertical corrections.
Dimming/ Shutte:
0%~100% smooth dimming,
0-12 Hz shutter effect
Colors:
Color plate :13 color white light, any half-color effect, with two-way rotation rainbow effect and Two-way Rainbow Effect.
Gobos:
Fixed Gobo: 11 Gobos + open
Rotating Gobo: 7 Gobos + open
Prism:
Prism 1: 6-facet linear prism, rotating
Prism 2: 8-facet round prism, rotating
Prism overlapping
Focus:
Electronic focus
Zoom
2.6°-42° electronic Zoom
Cooling:
Fan cooling.
Control:
DMX 512/Auto/Master/Slave
Signal input/output:
3 pin XLR signal interface
Net weight:
14Kg
Gross weight (carton):
17.5Kg
Product size:
571322255
Packing Size (Cartons):
580× 520 × 405mm

Product Illumination Chart

BEAM model:

SPOT model:

5

Wash model:

3. Description

3.1 Control Panel

front panel back panel

1. USB socket: USB connection data.

2. Display screen :After 30 seconds of standby, the key is automatically locked to prevent  misoperation.

Activate display by pressing and holding the MENU button for 2 seconds;

3. Button:

MENU

|

return

---|---

DOWN

|

To select or decrease value

UP

|

To select or increase value

ENTER

|

Enter menu selection function\confirm selected  function

---|---

4. DMX Input and Output:

For DMX 512 control,Use DMX cable with 3pin XLR In/Out to link DMX console and moving head.

5. Protective tube :Over current protection.

6. Power Input Block:Power supply.

7. Power output seatConnected Power Transmission

(110V power supply can connect up to 3 lamps,220 V power supply can connect up to 6 lamps).

4. Lamp  

OSRAM SIRIUS HRI ® 371W

There is high pressure inside the lamp and there is a risk of cracking during operation. The  ultraviolet light emitted by the lamp is harmful to the eyes and skin. Do not look directly when the  lamp is running.


1. In order to protect the lamp, please turn off the lamp first and run for at least 5 minutes before disconnecting  the power.

2. Do not touch the lamp with bare hands. Once in hand contact, scrub with alcohol and dry with a soft linen  cloth.

3. When the light is on, the lamp runs under high pressure, so there is a risk of rupture. The degree of  risk is related to the length of service time, temperature and unreasonable operation.Therefore,  please do not use lamps that exceed the service life.

4. Make sure the lamp is installed in the center to ensure the best lights effects.

 5.1 Lighting fixtures

 Go to menu mode by pressing the ENTER button. Use UP and DOWN buttons to select menus. Press  ENTER button to confirm when the preset menu is displayed on the display screen. Use the UP and  DOWN buttons to select the sub-menu, press the ENTER button to save the settings or automatically return to  the upper menu.Press the MENU button to return, or wait 30 seconds to automatically exit menu mode.

Press and hold MENU button for 3 seconds to enter menu mode without power connection. After  setting, press the ENTER button for 1 second or wait 40 seconds to automatically exit the setting  function.

The main features are shown below

Address Setting High Level Setting Running Mode

System Information Bulb Control Application Service

Menu operation


Level 1

menu

|

second-level menu

|

Three-level menu

|

Four-level menu

|

Five-level menu

Address

settings

|

001-512

|

|

|

Advanced  setup

|

X axis reverse

|

On/off

|

|

(Default closed)

Y axis reverse

|

On/off

|

|

(Default closed)

Screen rotation

|

Forward/reverse/auto matic

|

|

(default positive)

The screen is always  on

|

On/off

|

|

(Default closed)

Optocoupler

Correction

|

On/off

|

|

(Default on)

language

|

Chinese/English

|

|

(factory default

Chinese)

Error

|

On/off

|

|

(Default on)

Touch screen

calibration

|

Yes/No

|

|

Factory setting

|

|

|

Drop out

|

|

|

Running

mode

|

Select Channel Mode

|

(CH)

|

|

(factory default)

Streamlining Mode  20(CH)

|

|

View the current  channel

|

x-axis

|

0-255

|

…….

|

Functional channels

|

|

DMX mode

|

|

|

Self-propelled Mode

|

|

|

Sound Control Mode

|

|

Manual control lamps

|

Scene mode

|

Automatic

/1-10

|

|

Master-slave mode

|

Automatic/

host/ slave

|

|

|

Scene selection

|

01-10

|

Scenario settings

|

Scene time

|

0.00S

|

|

Drop out

|

|

|

|

01X axis

|

0-255

---|---|---|---|---

|

|

….

|

0-255

|

|

24 Reset

function

|

0-255

Running

mode

|

Manual control lamps

|

Lamp reset

|

X axis Y axis

|

Yes/No

Dyestuff

|

Yes/No

Wheel

|

Yes/No

strobe

|

Yes/No

Focus and Prism

|

Yes/No

Whole

|

Yes/No

Drop out

|

Drop out

|

|

Drop out

|

|

|

System

information

|

Equipment Version  Number

|

|

|

Device status

|

|

|

Error recording

|

|

|

Light source time

|

|

|

Equipment running  time

|

|

|

Drop out

|

|

|

Light lamp control

|

Bright bubbles

|

On/off

|

|

(Default closed)

Turn on the light  lamp

|

On/off

|

|

(Default closed)

Control of Bright  Bubbles

|

On/off

|

|

(Default closed)

Bubble opening delay

|

0-535

|

|

Half power delay

|

0-535

|

|

Reset lamp time

|

Yes/No

|

|

Light lamp timing  maintenance

|

Internal use

|

0-255

|

Remaining

maintenance time

|

Heavy/No

|

Drop out

|

|

|

Application

|

Service contact

information

|

|

|

service

|

Equipment

maintenance

|

|

|

Equipment fine

calibration

|

|

|

---|---|---|---

Equipment data

removal

|

|

|

Equipment usage  records

|

|

|

Drop out

|

|

|

5.2 Error message

Temperature error

The temperature board may be damaged

Fan error

The fan and its control may be broken

Magnetic error

For the magnetic sensing function part may be broken.

Optical Coupling Error

The optocoupler and its control may be broken.

The above conditions may occur when the machine is turned on or reset, possibly some parts are damaged. Please  contact the authorized maintenance centre.

 6. General DMX Controller Control

 1. In order to reduce signal errors and avoid signal weakening and interference during  transmission. The resistance of 90-120Ω(0.25W) can be added between 2 cores and 3 cores at  the DMX output of the last machine.

2. Connect the lamp with a XLR signal line, one end to the outlet of the lamp,the other end is connected to  the input port of the next lamp.XLR signal lines can only be used in series, not in parallel. DMX512  signal transmission is fast.Signal lines are damaged, welding is not secure, contact is not good.Will  affect signal transmission, causing the system to shut down

3. When the machine power supply of a unit is broken, the connection between DMX output and  input is bypassed in order to maintain the connection of the DMX line.Each lamp should have  an address code that can receive messages from the console, ranging from 0-512, usually 0&1  and 1 Same).

4. A terminal DMX512 the system needs to be assembled to reduce signal transmission errors. 5. 3 core XLR connector:

Three cores XLR :PIN 1:GND,PIN 2:negative, PIN 3:positive.

6.1 Channel settings

Press the ENTER button to enter the menu mode, Run Mode → Select Channel Mode, press the ENTER button to confirm, the current channel mode will flash on the display, use the UP  and DOWN buttons to select the full mode 24 (CH), press the ENTER button to save. Press the MENU  button to return to the previous menu or wait 30 seconds and automatically exit the menu mode.

6.2 Address code settings

When applying universal DMX controllers to control lamps, you need to set the starting address (1-512) for the  lamps so that the machine can receive DMX signals.

Press ENTER button to enter menu mode, select DMX function, press ENTER button to confirm,The current  address flashes on the display screen, then the UP/DOWN button is used to select the address  code (1-512), and the ENTER button is pressed to save it. Click the MENU button to return to the next menu or exit menu mode after waiting 30 seconds.

Please refer to the chart below to set the address code for the first 4 fixtures

Channel  Wheel

Lamps 1 Address  code

Lamps 2 Address  code

Lamps 3 Address  code

Lamps 4 Address  code

24 channels

20 channels

6.3 DMX 512 channels

1 25 49 73 1 21 41 61

Please refer to the following channel diagram to control the lamp

Notice :

  1. If DMX signal is fails, the light will remain in the state before the disconnect signal unless reset.

Channel table :

Standa rd

model  24

(CH )

Stream lining  model  20

(CH )

Channel Name Channel value Function

1

|

1

|

Pan

|

000-255

|

0-540 degrees

---|---|---|---|---

2

|

2

|

Pan fine

|

000-255

|

16 bit Adjustable

3

|

3

|

Tilt

|

000-255

|

0-270 degrees

4

|

4

|

Tilt fine

|

000-255

|

16 bit Adjustable

5

|

5

|

Pan/Tilt speed

|

000-255

|

From fast to slow

6

|

6

|

Dimmer

|

000-255

|

0-100% dimmer

7

|

|

Dimmer fine

|

000-255

|

16 bit Adjustable

8

|

7

|

Strobe

|

0-7

8-15

16-131

132-167

168-203

204-239

240-247

248-255

|

No function

Opening the light

Synchronous stroboscopic from  slow to fast

Turn it off, turn it off

Turn it off quickly, from slow to  fast

Pulse stroboscopic from slow to  fast

Random strobe, from slow to fast Opening the light

9

|

8

|

Colour wheel

|

0-4

5-9

10-14

15-19

20-24

25-29

30-34

35-39

40-44

45-49

50-54

55-59

60-64

65-69

|

White

Red

Blue

Green

Orange

Purple

Light yellow

Plum red

Pale blue purple

Cold colour

Blue Green

Yellow green

CTO5600K

Fluorescence

|

|

|

70-76

77-83

84-90

91-97

|

White light → red

Red → blue

Blue → green

Green → orange

---|---|---|---|---

98-104

105-111

112-118

119-125

126-132

133-139

140-146

147-152

153-159

160-219

220-223

224-255

|

Orange→purple

Fuchsia → light yellow

Light yellow → plum red

Plum red → light blue purple Light blue purple → cool color Cool color → blue green

Blue-green → yellow-green Yellow-green → CTO5600K CTO5600K→ Fluorescence

Positive rainbow, from fast to slow Stop

Reverse rainbow, from slow to  fast

10

|

9

|

Fixed Gobo

wheel

|

0-3

4-7

8-11

12-15

16-19

20-23

24-27

28-31

32-35

36-39

40-43

44-47

48-51

52-55

56-59

60-63

64-67

68-71

72-75

76-79

80-83

84-87

88-91

|

Open

Gobo 1

Gobo 2

Gobo 3

Gobo 4

Gobo 5

Gobo 6

Gobo 7

Gobo 8

Gobo 9

Gobo 10

Gobo 11

Gobo 11 shaking from slow to fast Gobo 10 shaking from slow to fast Gobo 9 shaking from slow to fast

Gobo 8 shaking from slow to fast Gobo 7 shaking from slow to fast Gobo 6 shaking from slow to fast Gobo 5 shaking from slow to fast Gobo 4 shaking from slow to fast Gobo 3 shaking from slow to fast Gobo 2 shaking from slow to fast Gobo 1 shaking from slow to fast

|

|

|

92-95

96-173

174-177

178-255

|

Open

Gobo wheel clock-wise rotates  from slow to fast

Stop

Gobo wheel counter clock-wise  rotates from slow to fast

---|---|---|---|---

11

|

10

|

Rotating Gobo

|

0-3

|

Open

4-6

|

filter gets in

7-13

|

Gobo 1

14-20

|

Gobo 2

21-27

|

Gobo 3

28-34

|

Gobo 4

35-41

|

Gobo 5

42-48

|

Gobo 6

49-55

|

Gobo 7

56-62

|

Gobo 1 shaking from slow to fast

63-69

|

Gobo 2 shaking from slow to fast

70-76

|

Gobo 3 shaking from slow to fast

77-83

|

Gobo 4 shaking from slow to fast

84-90

|

Gobo 5 shaking from slow to fast

91-97

|

Gobo 6 shaking from slow to fast

98-104

|

Gobo 7 shaking from slow to fast

105-109

|

Open

110-180

|

Gobo wheel clock-wise rotates  from slow to fast

181-184

|

Stop

185-255

|

Gobo wheel counter clock-wise  rotates from slow to fast

12

|

11

|

Gobo rotating

|

0-63

|

Forward rotation, from slow to fast

64-145

|

Rotating pattern hovering position

146-150

|

Stop

151-231

|

Rotate forward and backward from slow to fast

232-255

|

Reverse rotation, from slow to fast

13

|

|

Gobo rotating  fine

|

000-255

|

16 bit Adjustable

14

|

12

|

Prism 1

|

0-15

16-255

|

No functioning

6-facet linear prism

15

|

13

|

Prism 1 rotation

|

0-127

128-189

|

prism rotation position

Forward rotation, from fast to

|

|

|

190-193

194-255

|

slow

Stop

Reverse rotation, from slow to fast

---|---|---|---|---

16

|

14

|

Prism 2

|

0-15

16-255

|

No functioning

8-facet round prism

17

|

15

|

Prism 2 rotation

|

0-127

128-189

190-193

|

Prism rotation position

Forward rotation, from fast to  slow

Stop

194-255

|

Reverse rotation, from slow to fast

18

|

16

|

Frost

|

0-15

16-255

|

No functioning

Frost

19

|

17

|

Focus

|

0-255

|

Adjust the focus

20

|

|

Focus fine

|

0-255

|

16 bit Adjustable

21

|

18

|

Zoom

|

0-255

|

From max. to min.

22

|

|

Zoom fine

|

0-255

|

16 bit Adjustable

23

|

19

|

Effect

|

0-255

|

No

24

|

20

|

Function channel

|

0-129

130-139

140-199

200-209

210-219

220-229

230-239

240-255

|

No function

Lamp on

No function

All reset

No function

No function

Lamp off

No function

7. Fault treatment

The following are some of the problems that often occur in operation, with some suggestions for  troubleshooting:

A. Lamps do not work, no lights,Fan does not rotate

1. Check for electrical contact and fuse integrity.

2. Detection voltage.

3. Check the power switch indicator.

B. Control of uncontrolled stations

1. Check DMX signal connectors and signal lines to see if they are connected correctly.

2. Check that the address code is set correctly.

3. If DMX signal is intermittent, check that the Canon is connected to the signal line.

4. Try the other controllers.

5. Check that DMX signal lines and high voltage wires are too close to each other, which can damage or  interfere with signal circuits.

C. One channel failed

1. The stepper motor or motor lead may be damaged.

2. The drive circuit of the motor may be damaged.

D. Light lamps are good and bad

1. The light lamp can not be lit normally. See if the voltage is too high or too low.

2. The internal temperature may be too high. If necessary, replace the cooling fan.

 8. Maintenance and cleaning

Maintenance:

Ballast resistor

A. When the color of each pin of the ballast is yellow, please consider replacing it in time.

B. Be sure to maintain the machine every 2 months and ensure that all parts of the screws and  terminals shown above are locked and not loosened. To ensure performance. Poor maintenance may cause malfunction of the machine.

cleaning:

The inside and outside of the lens and the reflector must be cleaned regularly so that the lighting  can be better. The wiping frequency depends on the environment. Wet, smoky, especially dirty  environment easy to dust the lens.

  • Soft linen and special glass scrub.

  • Carefully wipe the cadres.

  • Wipe the outside of the lens at least every 20 days. Clean the interior at least every 30 days. Clean the dust-proof sponge on the bottom cover at least every 30 days (depending on the actual environment)

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>