AVTech HYBRID18R 370W 3 In 1 LED Moving Head User Manual
- June 4, 2024
- AVTECH
Table of Contents
- HYBRID18R 370W 3 In 1 LED Moving Head
- HYBRID18R
- 370W 3in1 LED Moving Head
- 2. Technical specifications
- Product Illumination Chart
- 3. Description
- 3. Button:
- 4. DMX Input and Output:
- 4. Lamp
- 5.1 Lighting fixtures
- 5.2 Error message
- 6. General DMX Controller Control
- 6.1 Channel settings
- 6.2 Address code settings
- 6.3 DMX 512 channels
- 7. Fault treatment
- 8. Maintenance and cleaning
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
HYBRID18R 370W 3 In 1 LED Moving Head
HYBRID18R
370W 3in1 LED Moving Head
USER MANUAL
Warning
Before using this product, Please read the instructions carefully.
Please keep this instruction, As a basis for future advice, If you sell this product to other users, Please make sure they also get this manual.
Please use it correctly on the basis of understanding the content.
Note :
The equipment is well packed when it leaves the factory, Please follow the user Manual to operate, human causes of machine failure is not covered by warranty.
⬥ Before using the product, Please open and check carefully to ensure that the lamps are not damaged by transportation.
⬥ The lamp is suitable for indoor drying only.
⬥ Installation and operation of lamps and lanterns should be carried out by professionals.
⬥ Don’t let children operate machines.
⬥ Use a safety cord when fixing equipment, lift the bottom while moving the lamp.
⬥ Equipment must be installed in good ventilation at least 50 cm from adjacent plane.
⬥ Make sure the ventilation hole is unobstructed so as not to overheat the lamp during operation.
⬥ Ensure that the power supply voltage is in line with the required power supply voltage before operation.
⬥ Please ground the conductive body to prevent electric shock.
⬥ Ambient temperature: do not run lamps below-25℃ or above 45℃.
⬥ It is forbidden to connect lamps directly to dimming equipment.
⬥ Do not place combustible items within 1 meter next to the lamp to prevent fire.
⬥ Please check carefully whether the power cord is damaged before opening the lamp. If there is any damage, please replace it immediately.
⬥ Lamp operation surface temperature can reach 55℃, do not touch with bare hands.
⬥ Avoid flammable liquids, water or metal conductors entering the interior of the lamp to avoid electric shock or fire.If any foreign body enters the lamp, please cut off the power immediately.
⬥ Avoid operating in dirty, dusty environment, and regularly clean and maintain lamps.
⬥ Do not touch the wire when the lamp is running to prevent electric shock.
⬥ Avoid winding power cord with other wire.
⬥ Distance between lamp and irradiation surface is greater than 15 M.
⬥ Disconnect the power before replacing the fuse or bulb.
⬥ Use the same model to replace fuse or bulb.
⬥ Serious Operation Failure Occurred,please stop using it immediately.
⬥ Do not repeat opening.
⬥ Please replace the case, lens or UV filter visible damage.
⬥ No spare parts inside the lamp, do not open the lamp shell without authorization.
⬥ Do not operate the machine on your own, non-professional operation will cause damage to the equipment or functional failure, For maintenance, please contact the nearest authorized service center.
⬥ Please cut off the power supply when the lamp is not used or repaired for a long time.
⬥ For re-transportation, please use the original package.
⬥ To avoid fire or electric shock, do not expose lamps to rain or wet areas.
⬥ High temperature light bulb is in danger of explosion, do not turn on the lamp within 15 minutes of power failure.
⬥ Light bulb damage, thermal deformation or beyond service life please replace in time.
⬥ Do not look directly at the lamp in operation.
⬥ Do not look directly at the lamp in operation.
⬥ The plug must be grounded in operation.
⬥ Do not operate the machine when the lamp has no shield or shell damage.
2. Technical specifications
Source:
10~240,50/60Hz
Power:
530W(90V)
Lamp bulb:
OSRAM SIRIUS HRI 371W.(Light bulb rated life:≥1500H)
Colour temperature :8000K
Power off display function :
Connect the USB socket when power is off you can enter the menu to set the
address code
and other settings.
Optical system:
Efficient optical systems
Strong Optical Output
High quality optical lens
Mobile:
Level:540°.
Vertical:270°.
The speed of horizontal / vertical movement can be adjusted.
Automatic completion of horizontal/vertical corrections.
Dimming/ Shutte:
0%~100% smooth dimming,
0-12 Hz shutter effect
Colors:
Color plate :13 color white light, any half-color effect, with two-way
rotation rainbow effect and Two-way Rainbow Effect.
Gobos:
Fixed Gobo: 11 Gobos + open
Rotating Gobo: 7 Gobos + open
Prism:
Prism 1: 6-facet linear prism, rotating
Prism 2: 8-facet round prism, rotating
Prism overlapping
Focus:
Electronic focus
Zoom
2.6°-42° electronic Zoom
Cooling:
Fan cooling.
Control:
DMX 512/Auto/Master/Slave
Signal input/output:
3 pin XLR signal interface
Net weight:
14Kg
Gross weight (carton):
17.5Kg
Product size:
571322255
Packing Size (Cartons):
580× 520 × 405mm
Product Illumination Chart
BEAM model:
SPOT model:
5
Wash model:
3. Description
3.1 Control Panel
front panel back panel
1. USB socket: USB connection data.
2. Display screen :After 30 seconds of standby, the key is automatically locked to prevent misoperation.
Activate display by pressing and holding the MENU button for 2 seconds;
3. Button:
MENU
|
return
---|---
DOWN
|
To select or decrease value
UP
|
To select or increase value
ENTER
|
Enter menu selection function\confirm selected function
---|---
4. DMX Input and Output:
For DMX 512 control,Use DMX cable with 3pin XLR In/Out to link DMX console and moving head.
5. Protective tube :Over current protection.
6. Power Input Block:Power supply.
7. Power output seatConnected Power Transmission
(110V power supply can connect up to 3 lamps,220 V power supply can connect up to 6 lamps).
4. Lamp
OSRAM SIRIUS HRI ® 371W
There is high pressure inside the lamp and there is a risk of cracking during operation. The ultraviolet light emitted by the lamp is harmful to the eyes and skin. Do not look directly when the lamp is running.
1. In order to protect the lamp, please turn off the lamp first and run for at least 5 minutes before disconnecting the power.
2. Do not touch the lamp with bare hands. Once in hand contact, scrub with alcohol and dry with a soft linen cloth.
3. When the light is on, the lamp runs under high pressure, so there is a risk of rupture. The degree of risk is related to the length of service time, temperature and unreasonable operation.Therefore, please do not use lamps that exceed the service life.
4. Make sure the lamp is installed in the center to ensure the best lights effects.
5.1 Lighting fixtures
Go to menu mode by pressing the ENTER button. Use UP and DOWN buttons to select menus. Press ENTER button to confirm when the preset menu is displayed on the display screen. Use the UP and DOWN buttons to select the sub-menu, press the ENTER button to save the settings or automatically return to the upper menu.Press the MENU button to return, or wait 30 seconds to automatically exit menu mode.
Press and hold MENU button for 3 seconds to enter menu mode without power connection. After setting, press the ENTER button for 1 second or wait 40 seconds to automatically exit the setting function.
The main features are shown below
Address Setting High Level Setting Running Mode
System Information Bulb Control Application Service
Menu operation
Level 1
menu
|
second-level menu
|
Three-level menu
|
Four-level menu
|
Five-level menu
Address
settings
|
001-512
|
|
|
Advanced setup
|
X axis reverse
|
On/off
|
|
(Default closed)
Y axis reverse
|
On/off
|
|
(Default closed)
Screen rotation
|
Forward/reverse/auto matic
|
|
(default positive)
The screen is always on
|
On/off
|
|
(Default closed)
Optocoupler
Correction
|
On/off
|
|
(Default on)
language
|
Chinese/English
|
|
(factory default
Chinese)
Error
|
On/off
|
|
(Default on)
Touch screen
calibration
|
Yes/No
|
|
Factory setting
|
|
|
Drop out
|
|
|
Running
mode
|
Select Channel Mode
|
(CH)
|
|
(factory default)
Streamlining Mode 20(CH)
|
|
View the current channel
|
x-axis
|
0-255
|
…….
|
Functional channels
|
|
DMX mode
|
|
|
Self-propelled Mode
|
|
|
Sound Control Mode
|
|
Manual control lamps
|
Scene mode
|
Automatic
/1-10
|
|
Master-slave mode
|
Automatic/
host/ slave
|
|
|
Scene selection
|
01-10
|
Scenario settings
|
Scene time
|
0.00S
|
|
Drop out
|
|
|
|
01X axis
|
0-255
---|---|---|---|---
|
|
….
|
0-255
|
|
24 Reset
function
|
0-255
Running
mode
|
Manual control lamps
|
Lamp reset
|
X axis Y axis
|
Yes/No
Dyestuff
|
Yes/No
Wheel
|
Yes/No
strobe
|
Yes/No
Focus and Prism
|
Yes/No
Whole
|
Yes/No
Drop out
|
Drop out
|
|
Drop out
|
|
|
System
information
|
Equipment Version Number
|
|
|
Device status
|
|
|
Error recording
|
|
|
Light source time
|
|
|
Equipment running time
|
|
|
Drop out
|
|
|
Light lamp control
|
Bright bubbles
|
On/off
|
|
(Default closed)
Turn on the light lamp
|
On/off
|
|
(Default closed)
Control of Bright Bubbles
|
On/off
|
|
(Default closed)
Bubble opening delay
|
0-535
|
|
Half power delay
|
0-535
|
|
Reset lamp time
|
Yes/No
|
|
Light lamp timing maintenance
|
Internal use
|
0-255
|
Remaining
maintenance time
|
Heavy/No
|
Drop out
|
|
|
Application
|
Service contact
information
|
|
|
service
|
Equipment
maintenance
|
|
|
Equipment fine
calibration
|
|
|
---|---|---|---
Equipment data
removal
|
|
|
Equipment usage records
|
|
|
Drop out
|
|
|
5.2 Error message
Temperature error
The temperature board may be damaged
Fan error
The fan and its control may be broken
Magnetic error
For the magnetic sensing function part may be broken.
Optical Coupling Error
The optocoupler and its control may be broken.
The above conditions may occur when the machine is turned on or reset, possibly some parts are damaged. Please contact the authorized maintenance centre.
6. General DMX Controller Control
1. In order to reduce signal errors and avoid signal weakening and interference during transmission. The resistance of 90-120Ω(0.25W) can be added between 2 cores and 3 cores at the DMX output of the last machine.
2. Connect the lamp with a XLR signal line, one end to the outlet of the lamp,the other end is connected to the input port of the next lamp.XLR signal lines can only be used in series, not in parallel. DMX512 signal transmission is fast.Signal lines are damaged, welding is not secure, contact is not good.Will affect signal transmission, causing the system to shut down
3. When the machine power supply of a unit is broken, the connection between DMX output and input is bypassed in order to maintain the connection of the DMX line.Each lamp should have an address code that can receive messages from the console, ranging from 0-512, usually 0&1 and 1 Same).
4. A terminal DMX512 the system needs to be assembled to reduce signal transmission errors. 5. 3 core XLR connector:
Three cores XLR :PIN 1:GND,PIN 2:negative, PIN 3:positive.
6.1 Channel settings
Press the ENTER button to enter the menu mode, Run Mode → Select Channel Mode, press the ENTER button to confirm, the current channel mode will flash on the display, use the UP and DOWN buttons to select the full mode 24 (CH), press the ENTER button to save. Press the MENU button to return to the previous menu or wait 30 seconds and automatically exit the menu mode.
6.2 Address code settings
When applying universal DMX controllers to control lamps, you need to set the starting address (1-512) for the lamps so that the machine can receive DMX signals.
Press ENTER button to enter menu mode, select DMX function, press ENTER button to confirm,The current address flashes on the display screen, then the UP/DOWN button is used to select the address code (1-512), and the ENTER button is pressed to save it. Click the MENU button to return to the next menu or exit menu mode after waiting 30 seconds.
Please refer to the chart below to set the address code for the first 4 fixtures
Channel Wheel
Lamps 1 Address code
Lamps 2 Address code
Lamps 3 Address code
Lamps 4 Address code
24 channels
20 channels
6.3 DMX 512 channels
1 25 49 73 1 21 41 61
Please refer to the following channel diagram to control the lamp
Notice :
- If DMX signal is fails, the light will remain in the state before the disconnect signal unless reset.
Channel table :
Standa rd
model 24
(CH )
Stream lining model 20
(CH )
Channel Name Channel value Function
1
|
1
|
Pan
|
000-255
|
0-540 degrees
---|---|---|---|---
2
|
2
|
Pan fine
|
000-255
|
16 bit Adjustable
3
|
3
|
Tilt
|
000-255
|
0-270 degrees
4
|
4
|
Tilt fine
|
000-255
|
16 bit Adjustable
5
|
5
|
Pan/Tilt speed
|
000-255
|
From fast to slow
6
|
6
|
Dimmer
|
000-255
|
0-100% dimmer
7
|
|
Dimmer fine
|
000-255
|
16 bit Adjustable
8
|
7
|
Strobe
|
0-7
8-15
16-131
132-167
168-203
204-239
240-247
248-255
|
No function
Opening the light
Synchronous stroboscopic from slow to fast
Turn it off, turn it off
Turn it off quickly, from slow to fast
Pulse stroboscopic from slow to fast
Random strobe, from slow to fast Opening the light
9
|
8
|
Colour wheel
|
0-4
5-9
10-14
15-19
20-24
25-29
30-34
35-39
40-44
45-49
50-54
55-59
60-64
65-69
|
White
Red
Blue
Green
Orange
Purple
Light yellow
Plum red
Pale blue purple
Cold colour
Blue Green
Yellow green
CTO5600K
Fluorescence
|
|
|
70-76
77-83
84-90
91-97
|
White light → red
Red → blue
Blue → green
Green → orange
---|---|---|---|---
98-104
105-111
112-118
119-125
126-132
133-139
140-146
147-152
153-159
160-219
220-223
224-255
|
Orange→purple
Fuchsia → light yellow
Light yellow → plum red
Plum red → light blue purple Light blue purple → cool color Cool color → blue green
Blue-green → yellow-green Yellow-green → CTO5600K CTO5600K→ Fluorescence
Positive rainbow, from fast to slow Stop
Reverse rainbow, from slow to fast
10
|
9
|
Fixed Gobo
wheel
|
0-3
4-7
8-11
12-15
16-19
20-23
24-27
28-31
32-35
36-39
40-43
44-47
48-51
52-55
56-59
60-63
64-67
68-71
72-75
76-79
80-83
84-87
88-91
|
Open
Gobo 1
Gobo 2
Gobo 3
Gobo 4
Gobo 5
Gobo 6
Gobo 7
Gobo 8
Gobo 9
Gobo 10
Gobo 11
Gobo 11 shaking from slow to fast Gobo 10 shaking from slow to fast Gobo 9 shaking from slow to fast
Gobo 8 shaking from slow to fast Gobo 7 shaking from slow to fast Gobo 6 shaking from slow to fast Gobo 5 shaking from slow to fast Gobo 4 shaking from slow to fast Gobo 3 shaking from slow to fast Gobo 2 shaking from slow to fast Gobo 1 shaking from slow to fast
|
|
|
92-95
96-173
174-177
178-255
|
Open
Gobo wheel clock-wise rotates from slow to fast
Stop
Gobo wheel counter clock-wise rotates from slow to fast
---|---|---|---|---
11
|
10
|
Rotating Gobo
|
0-3
|
Open
4-6
|
filter gets in
7-13
|
Gobo 1
14-20
|
Gobo 2
21-27
|
Gobo 3
28-34
|
Gobo 4
35-41
|
Gobo 5
42-48
|
Gobo 6
49-55
|
Gobo 7
56-62
|
Gobo 1 shaking from slow to fast
63-69
|
Gobo 2 shaking from slow to fast
70-76
|
Gobo 3 shaking from slow to fast
77-83
|
Gobo 4 shaking from slow to fast
84-90
|
Gobo 5 shaking from slow to fast
91-97
|
Gobo 6 shaking from slow to fast
98-104
|
Gobo 7 shaking from slow to fast
105-109
|
Open
110-180
|
Gobo wheel clock-wise rotates from slow to fast
181-184
|
Stop
185-255
|
Gobo wheel counter clock-wise rotates from slow to fast
12
|
11
|
Gobo rotating
|
0-63
|
Forward rotation, from slow to fast
64-145
|
Rotating pattern hovering position
146-150
|
Stop
151-231
|
Rotate forward and backward from slow to fast
232-255
|
Reverse rotation, from slow to fast
13
|
|
Gobo rotating fine
|
000-255
|
16 bit Adjustable
14
|
12
|
Prism 1
|
0-15
16-255
|
No functioning
6-facet linear prism
15
|
13
|
Prism 1 rotation
|
0-127
128-189
|
prism rotation position
Forward rotation, from fast to
|
|
|
190-193
194-255
|
slow
Stop
Reverse rotation, from slow to fast
---|---|---|---|---
16
|
14
|
Prism 2
|
0-15
16-255
|
No functioning
8-facet round prism
17
|
15
|
Prism 2 rotation
|
0-127
128-189
190-193
|
Prism rotation position
Forward rotation, from fast to slow
Stop
194-255
|
Reverse rotation, from slow to fast
18
|
16
|
Frost
|
0-15
16-255
|
No functioning
Frost
19
|
17
|
Focus
|
0-255
|
Adjust the focus
20
|
|
Focus fine
|
0-255
|
16 bit Adjustable
21
|
18
|
Zoom
|
0-255
|
From max. to min.
22
|
|
Zoom fine
|
0-255
|
16 bit Adjustable
23
|
19
|
Effect
|
0-255
|
No
24
|
20
|
Function channel
|
0-129
130-139
140-199
200-209
210-219
220-229
230-239
240-255
|
No function
Lamp on
No function
All reset
No function
No function
Lamp off
No function
7. Fault treatment
The following are some of the problems that often occur in operation, with some suggestions for troubleshooting:
A. Lamps do not work, no lights,Fan does not rotate
1. Check for electrical contact and fuse integrity.
2. Detection voltage.
3. Check the power switch indicator.
B. Control of uncontrolled stations
1. Check DMX signal connectors and signal lines to see if they are connected correctly.
2. Check that the address code is set correctly.
3. If DMX signal is intermittent, check that the Canon is connected to the signal line.
4. Try the other controllers.
5. Check that DMX signal lines and high voltage wires are too close to each other, which can damage or interfere with signal circuits.
C. One channel failed
1. The stepper motor or motor lead may be damaged.
2. The drive circuit of the motor may be damaged.
D. Light lamps are good and bad
1. The light lamp can not be lit normally. See if the voltage is too high or too low.
2. The internal temperature may be too high. If necessary, replace the cooling fan.
8. Maintenance and cleaning
Maintenance:
Ballast resistor
A. When the color of each pin of the ballast is yellow, please consider replacing it in time.
B. Be sure to maintain the machine every 2 months and ensure that all parts of the screws and terminals shown above are locked and not loosened. To ensure performance. Poor maintenance may cause malfunction of the machine.
cleaning:
The inside and outside of the lens and the reflector must be cleaned regularly so that the lighting can be better. The wiping frequency depends on the environment. Wet, smoky, especially dirty environment easy to dust the lens.
-
Soft linen and special glass scrub.
-
Carefully wipe the cadres.
-
Wipe the outside of the lens at least every 20 days. Clean the interior at least every 30 days. Clean the dust-proof sponge on the bottom cover at least every 30 days (depending on the actual environment)
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>