FUTECH 850.060DM 60cm Digital Level User Manual

June 4, 2024
FUTECH

FUTECH 850.060DM 60cm Digital Level

FUTECH-850-060DM-60cm-Digital-Level-product

FAQ

Frequently Asked Questions

  • Q: How often should calibration be done?
    • A: Calibration is recommended before each use to ensure accurate readings.
  • Q: What should I do if the battery indicator is flashing?
    • A: Replace the batteries with fresh ones to maintain proper functionality.

OVERVIEW

FUTECH-850-060DM-60cm-Digital-Level-fig-1

DEVICE

  1. ON/OFF button
  2. MODE button
  3. Reference Button
  4. HOLD button
  5. SOUND Button
  6. LIGHT Button
  7. Calibration button
  8. LCD display
  9. Battery cover

DISPLAY

  • A Sound indicator

  • B HOLD indicator

  • C Reference indicator

  • D mm/m measuring unit
    E in/ft measuring unit

  • F % measuring unit

  • G degree measuring unit

  • H Battery indicator

  • I Level indicators

  • J Main display

SAFETY AND BATTERY

SAFETY

  • Please read the complete safety instructions in the booklet delivered with this device.
  • When the product won’t be used for a long time, extract the batteries.

BATTERY

  • Open the battery compartment [09] and insert the 2 x AAA batteries (DC 4.5V) . Make sure the batteries are in the correct position.
  • When batteries are less then 5% charged, the battery indicator [H] will start flashing.

FIRST TIME USAGE

  • Remove all protection foils.

USE

POWER ON/OFF

  • To power on the product, press the On/Off button [01] shortly. The LCD display [08] turns on.
  • To switch off the product, shortly press the ON/ Off button [01]. The device powers off.

UNITS

Several units are available to show the slope. The different options are: degrees (°), millimeter per meter (mm/m), percentage (%), inch/feet (in/ft).

  • Press the Mode button [02] shortly to change the unit.

The selected unit is shown in the upper right corner of the LCD display [08].

BACKLIGHT

  • The display backlight increases visibility in less bright environments.
  • Press the light button [06] to change the setting of the backlight.

AUTOMATIC SHUT OFF

To save battery power, the digital level will switch itself off if not used for a certain time. This time can be set to 5 minutes or 2 hours.

  • Hold the Mode button [02] to select the preferred shut off time.

The LCD display [08] shows ‘5’ for 5 minutes or ‘2H’ for 2 hours.
When 2 hours is selected, the battery indicator [H] stays on th display to remind you the 2 hour function is active.
Default setting is 5 minutes.

NOTE

  • When the battery is less than 5% charged, the system automatically shuts of the product after 5 minutes. Holding the mode button [02] will not initiate the setting options.

ZERO REFERENCE

  • This function allows the user to set every slope as reference (0°).
  • This feature is useful when measuring the same slope over and over or finding the difference between two slopes.

SETTING REFERENCE

  • Position the level under the required slope to use it as reference.
  • Press the Reference button [03] to program that angle as reference slope.

To find, for example, the difference between that and a second slope, now hold the device on the second slope and the difference in angle is directly displayed.

EXITING REFERENCE MODE

  • Press the [03] Reference button shortly to deactivate the Reference function.

HOLD FUNCTION

The hold button is a useful functionality when you are not able to read the display while working.

  • Press the Hold button [04] to freeze the readout until you press the button again. ‘HOLD’ [B] is displayed on the LCD display.
  • Press the Hold button [04] again to turn off the hold function.

SOUND NOTIFICATION

Sound assistance can be used for work in case that looking at the LCD is not possible.

  • Press the Sound button [05] to enable the sound mode.
  • Once activated, a sound symbol [A] is visible on the LCD display [08].
  • Press the Sound button [05] agian to disable the sound mode.
  • The sound symbol [A] is no longer visible on the LCD display [08].

These beeps can be heard:

The inclination arrows [I] provide the desired turning direction. When levelled (0° or 90°), the display shows two hyphens at both sides of the LCD Display [08].

CALIBRATING DEVICE

NOTE

  • Calibration is recommended before each use.
  • An ‘ERROR’ message is displayed when the product tilts too much for- or backwards (to display an accurate reading).
  • Two different types of calibration are available:

QUICK LEVEL/PLUMB CALIBRATION

This method is used to (level/plumb) calibrate the device quickly.

  • Turn on the digital level
  • Hold the device against a (flat) surface/wall making sure the level bubble is centered.
  • When holding the device in this position, hold the calibration button [07] for 3 seconds.

When done properly, the LCD Display [08] will flash ‘CAL’ on the screen. The calibration process started.
When moving/tipping the device during this process, ‘ERROR’ appears on the [08] LCD Display.

  • To exit the calibration mode after an error, shortly press the calibration button [07].

You can restart the procedure. The calibration process is done when the LCD display [08] shows ‘RDY’. The device automatically leaves the calibration mode.

CALIBRATION

  • When calibrating the device, put the device on a flat surface (i.e. surface of table).
  • This surface will be the reference surface.
  • When holding the device under this angle, hold the calibration button [07] and the Mode button [02] for 3 seconds.
  • The calibration process initiated and the LCD Display [08] shows ‘CAL1’.
  • Push the Calibration button [07] shortly and the LCD Display [08] starts flashing ‘CAL1’.
  • When the LCD Display [08] shows ‘CAL2’, rotate the device 180° in such a way that the device is in the same position, but the screen faces now away from the user.
  • Push the Calibration [7] button shortly,
  • ‘CAL2’ will flash on the [08] LCD Display.

When ready, the device will automatically exit the calibration mode.

MAINTENANCE
  • Repairs or services are not covered in this manual and should only be carried out by qualified trained technicians.
  • Periodically, wipe the body with a dry cloth.
  • Do not use abrasives or solvents on this instrument. For service, use only manufacturer’s specified parts.

TECHNICAL SPECIFICATIONS

| 850.060DM DIGITAL LEVEL| 850.120DM DIGITAL LEVEL
---|---|---
Precision| ± 0.1º for 0º and 90º

± 0.2º for other angles

Protection| IP54
Resolution| 0.1º, 0.1%, 1/8”, .125”, 1 mm/m
Optional units| in/ft – mm/m – ° – %
Measurement range| 4 x 90°
Batteries| 2 x AAA
Battery life| ±100 hours (continuous use)
Dimensions (l x w x h)| 27 x 600 x 63 mm       27 x 1200 x 63

mm (120cm)

Weight| 0.67 kg                       1.29 kg
Working temperature| -10 °C < T < 50 °C

DECLARATION OF CONFORMITY

FUTECH-850-060DM-60cm-Digital-Level-fig-3

Potential misprints are reserved. Images used are not strict. All features, functionality and other product specifications are subject to change without notice or obligation.

USER MANUAL

other languages:

FUTECH-850-060DM-60cm-Digital-Level-fig-4

  • Facebook
    • @futechtools
  • LinkedIn
    • futechtools
  • World Wide Web
  • YouTube
    • @futechtools

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>