FUTECH 195.10 Hydro Ultrasonic Moisture Meter User Manual
- August 27, 2024
- FUTECH
Table of Contents
FUTECH 195.10 Hydro Ultrasonic Moisture Meter
Specifications
- Selected material: Various
- Battery: 2x AAA alkaline batteries
- Measuring depth: 15-20 mm
- Temperature units: Celsius/Fahrenheit
Product Usage
Turning On/Off the Device:
To turn the device on, briefly press the HOLD/ON button. Replace batteries if
the display is blank or shows low battery status. To turn off, press and hold
the OFF button until the device powers down.
FAQ
-
Q: How often should I use the auto zero mode?
A: The auto zero mode should be used periodically within a time range of 10-15 minutes to calibrate the humidity sensor readings to zero and avoid deviations in measurements. -
Q: What should I do if the display remains blank?
A: If the display remains blank, check the battery status indicator for low battery voltage and replace the batteries if needed.
OVERVIEW
-
Selected material
-
Battery status
-
Measurement recording (Hold)
-
Measuring result
-
Temperature
-
The number of chosen material group
-
Chosen density
-
Power ON / measurement hold button
-
Choosing material group button
-
Choosing material button
-
Power OFF (3 sec.)
-
Auto zero mode button
INTRODUCTION
On the front panel, there is a digital display (see picture) and a keyboard consisting of six buttons (see picture). The humidity sensor is located under the back panel of the device. The device is powered by 2x AAA alkaline batteries, housed in the battery compartment at the lower back part of the device.
APPLICATION FIELD
-
The device is made for the rapid moisture testing of various types of wood and concrete. The device measures the moisture content of a material, judging by its electrical resistance at a temperature above 0°C.
Variety of measuring items:- 8 groups – wood
- 6 groups – concrete (light and heavy), concrete blinding coat. Full list of material groups you can find in the application 1.
-
The main application field: various kinds of timber works, as well as construction production and technologies, in which the humidity of materials regulated by normative-technical or technical documentation.
-
The device produces with averaged characteristics settings.
-
Operating temperature: +5 … +40°C, with several humidity till 90% at the temperature 25°C and air-pressure 86 … 106 Pa.
OPERATION
TURN ON/OFF THE DEVICE
- Turn the device on by briefly pressing the HOLD/ON button. If the display remains blank or the battery status indicator shows low battery voltage, replace the power supply.
- To turn the device off, press and hold the OFF button until the device powers down.
- If no buttons are pressed for 20 seconds, the screen backlight will turn off. You can reactivate it by pressing any button.
- The device will automatically turn off after 1 minute of inactivity.
AUTO ZERO MODE
If you press button ZERO/SET, the device will enter auto zero mode. The following information will appear on the screen:
At this point, ensure the sensor of the device is at least 30 cm away from all objects, then press the ZERO/SET button again. The device will perform auto- tuning and then switch to measuring mode, as shown in the picture.
Using auto zero mode, you calibrate the humidity sensor readings to zero. To avoid deviations, the auto zero mode should be used periodically, within a time range of 10-15 minutes.
MEASURING MODE
After selecting the material using the / button and the material group using
the button, place the sensor plate on the testing surface. To obtain accurate
readings, ensure that the sensor fits snugly against the test surface, with no
gaps between the sensor and the surface. Then, read the result.
The surface should be even, clean, and homogeneous, without deep dents or
protrusions. While obtaining measurements, the device should be pressed
lightly against the test surface with a force of about 1 kg.
To hold the result on the screen, for example, when measuring a surface where
you cannot see the device, press the HOLD/ON button. “HOLD” will appear at the
top of the screen, and the last measured value will remain visible until you
press the HOLD/ON button again.
Moisture measurement results can be obtained for:
-
Wood
arithmetic mean of more than three measurements -
Concrete
arithmetic mean of more than five measurements
The measuring depth is 15-20 mm, depending on the moisture content and density of the material being measured. The device is calibrated for this depth. If the thickness of the chosen material is less than 15 mm, perform the measurement by holding the device with the material in the air to ensure the sensor does not pick up data from other materials.
To avoid deviations, use the auto zero mode (refer to “AUTO ZERO MODE”).
SENSOR TEMPERATURE UNITS
If you hold the button, the temperature unit changes from Celsius to Fahrenheit. A second long press will change it back to Celsius.
MAINTENANCE
Users should perform periodic preventive measures and checks.
- Keep the device clean and protected from bumps, dust, and moisture; wipe it with a clean, soft cloth after each use.
- If the battery status indicator shows low voltage, turn off the device and replace the power supply.
- Optimize battery life by turning on the device before measuring and turning it off after use.
- If the device becomes unresponsive during operation and does not turn off, open the battery compartment for a few seconds, remove one battery, reinsert it, and restart the instrument.
- If the device does not respond when turning it on, remove the batteries, clean the battery contacts with an alcohol-soaked swab or fine sandpaper, reinsert the batteries, and check if the device functions.
- Repairs must be conducted by authorized after-sales service centers. The device is a highly technical product and should not be repaired by users; therefore, we do not provide complete technical documentation to users
- For long-term storage, remove the batteries from the compartment to prevent damage from leakage.
COMPLETE SET
- Instrument 1x
- Battery 2x
- Manual 1x
- Bag 1x
SPECIFICATIONS
WORKING RANGE
CONSTRUCTION MATERIAL| Heavy concrete
(2400kg/m3) from 0,1 to 10%
Light concrete
(2200kg/m³) from 0,1 to 20%
Screed
__(1700-2000kg/m³) from 0,1 to 35%
Gypsum
(1400kg/m3) from 0,1 to 35%
WOOD| (420-700kg/m³) from 2 to 65%
ACCURACY WITHIN LIMITS, %
CONSTRUCTION MATERIAL| from 1 to 10%| up to ± 0,9%
from 10 to 35%| up to ± 1,5%
WOOD
| from 1 to 10%| up to ± 1,0%
from 10 to 20% up to ± 1,5%
from 20 to 45% up to ± 2,0%
from 45 to 65%| up to ± 2,5%
The device equipped with calibration curves on the following materials above “Working range”.
TECHNICAL SPECIFICATIONS
SCANNING DEPTH| Wood 20mm
Concrete 10mm
DENSITY RANGE
| Wood 420-700kg/m³ Concrete 1800-2400 kg/m³
TIMBER GROUP| 1-8
CONCRETE GROUP| 1-4
RESOLUTION| 0,1% humidity; 1°C / 1°F
MEASURING RANGE| Wood 2.0 -65%
Concrete 0-35%
TEMPERATURE RANGE| -10°C / +60°C
OPERATING TEMPERATURE| -0°C / +40 °C
POWER SUPPLY| 2x 1,5V AAA Alkaline batteries
POWER INPUT| 17mA (incl. lightning)
AUTO SHUT OFF FUNCTION| 1 minute
DIMENSIONS| 110x43x25mm
WEIGHT INCL. BATTERIES| 75 gram
POWER SUPPLY| 2x AAA batteries
POWER INPUT (WITH LED)| 17mA
OPERATING TIME| 10 hours
DIMENSIONS| 110x43x25mm
WEIGHT| 75g
The device constructed as an electronic unit with the integrated humidity sensor.
TIMBER TABLE
GROUP | DENSITY KG/M³ | SPECIES |
---|---|---|
1 | < 420 | Spurce, poplar, aspen |
--- | --- | --- |
2 | 421-460 | Pine, basswood, oregon |
3 | 461-500 | Alder, cedar, meranti |
4 | 501-540 | Larch, cherry, mahogany |
5 | 541-580 | Ramin, walnut, elm |
6 | 581-620 | Ash, maple, birch, teak |
7 | 621-660 | Beech, pear, yew |
8 | 661-700 | Oak, hickory |
CONCRETE TABLE | ||
GROUP | DENSITY KG/M³ | SPECIES |
--- | --- | --- |
1 | <1400 | Gypsum |
--- | --- | --- |
2 | 1401-1700 | Screed |
3 | 1701-1800 | Low density screed |
4 | 1801-2000 | Regular density screed |
5 | 2001-2200 | Light concrete |
6 | 2201-2400 | Heavy concrete |
NOTE
Since concrete production varies between brands, specific data such as density
(specific weight) must be obtained from the manufacturer. This information is
crucial for determining the correct group setting on the device.
USER MANUAL other languages:
Facebook
@futechtools
futechtools
LinkedIn
YouTube
futech-tools.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>