HOLMAN PRO469 Multi Program Irrigation Controller User Guide
- June 1, 2024
- Holman
Table of Contents
PRO469 Multi Program Irrigation Controller
“`html
Specifications
-
Available in 6 and 9 station configurations
-
Toroidal high capacity transformer rated to 1.25AMP (30VA)
-
3 programs, each with 4 start times, maximum of 12 start times
per day -
Station run times from 1 minute to 12 hours and 59 minutes
-
Selectable watering options: Individual 7 day selection, Even,
Odd, Odd -31, interval watering day selection from every day to
every 15th day -
Watering budgeting feature allows adjustment of station run
times by percentage, from OFF to 200%, by month -
Rain sensor input to turn off stations during wet periods
-
Permanent memory feature retains automatic programs during
power failures -
Manual functions for program and station operation
-
Pump output to drive a 24VAC coil
-
Real-time clock backed up with 3V Lithium battery
-
Contractor recall feature
Product Usage Instructions
Correct Power-up Procedure
- Connect the controller to AC power.
- Install a 9V battery to extend the life of the coin
battery.
Programming
- Set Automatic Program:
…
Manual Operation
- To run a single station:
…
FAQs
How can I set the watering days?
To set the watering days, navigate to the programming section
and select the watering days option. Choose from options such as
Individual 7 day selection, Even, Odd, etc., based on your
requirements.
How does the rain sensor feature work?
The rain sensor input will automatically turn off all stations
or selected stations when it detects wet conditions. Ensure a rain
sensor is installed and properly connected for this feature to
function.
“`
1 of 20
User Guide
Contents
Introduction Correct Power-up Procedure
Features Overview Programming
Set Automatic Program Set Current Time, Day and Date Set Start Times Set
Watering Days Set Run Times Set Additional Programs Manual Operation Run a
Single Station Edit the Default Manual Run Time Run a Program Stacking
Programs Other Features Stop Watering Stacking Start Times Automatic Backup
Rain Sensor Rain Delay Dual Pump Selection Display Contrast Water Budgeting
and Seasonal Adjustment Fault Indication Feature System Test Clearing the
Programs Program Rescue Feature
3 Installation
12
3
Mounting the Controller
12
3
Electrical Hook-up
12
4
Field Wiring Connections
12
5
Power Supply Connections
12
5
Terminal Block Layout
13
5
Valve Installation and Power Supply Connection 13
6
Station Valve Installation
14
6
Pump Start Relay Connection
15
7
Pump Protection (System Test)
15
7
Single Phase Pump Installation
15
8 Troubleshooting
16
8 Electrical Specifications
17
8
Electrical Outputs
17
8
Overload Protection
17
8
Power Failure
17
9
Wiring
17
9 Servicing
18
9
Servicing your Controller
18
9 Warranty
19
9
10
10
10
10
11
11
11
11
2 of 20
Introduction
Your PRO469 Multi-Program Irrigation Controller is available in 6 and 9
station configurations. Designed to cover a wide range of applications from
residential and commercial turf, to light agriculture, and professional
nursery.
This controller has a possible 3 separate programs with up to 12 starts per
day. The controller has a 7 day watering schedule with individual day
selection per program or a 365 calendar for odd/even day watering or
selectable interval watering schedules from every day to every 15th day.
Individual stations can be allocated to one or all programs and can have a run
time of 1 minute to 12 hours 59 minutes or 25 hours if the water budget is set
to 200%. Now with “Water Smart Seasonal Set” which allows the automatic run
times to be adjusted in percentage from “OFF” to 200% per month.
We have always been concerned with sustainable water usage. The controller has
many water saving features that can be used to maintain the highest standard
of plant quality with the least amount of water consumption. The integrated
budget facility allows global changes of run times without affecting
programmed run times. This allows for decreasing total water consumption on
days of minimal evaporation.
Correct Power-up Procedure
1. Connect to AC Power
2. Install a 9V battery to increase the life of the coin battery
® Batteries will maintain the clock
Features
L 6 and 9 station models
L Toroidal high capacity transformer rated to 1.25AMP (30VA)
L Outdoor model with an inbuilt transformer includes lead and plug, for
Australia
L 3 programs, each of which has 4 start times, maximum of 12 start times per
day
L Station run times from 1 minute to 12 hours and 59 minutes
L Selectable watering options: Individual 7 day selection, Even, Odd, Odd -31,
interval watering day selection from every day to every 15th day
L Watering budgeting feature allows quick adjustment of the station run times
by percentage, from OFF to 200%, by month
L Rain sensor input will turn off all stations or selected stations during wet
periods, if a sensor is installed
L Permanent memory feature will retain automatic programs during power
failures
L Manual functions: run a program or group of programs once, run a single
station, with a test cycle for all stations, OFF position to stop a watering
cycle or to stop automatic programs during winter
L Pump output to drive a 24VAC coil
L Real-time clock backed up with 3V Lithium battery (pre-fitted)
L Contractor recall feature
3 of 20
Overview
2
3
4
5
1
6
7 8
9
1. LCD display
4 of 20
7. MAIN DIAL 8. SENSOR switch 9. Terminal cover
Programming
This controller has been designed with 3 separate programs to allow different
landscape areas to have their own individual watering schedules
A PROGRAM is a method of grouping stations (valves) with similar watering
requirements to water on the same days. These stations will water in
sequential order and on the days selected.
L Group the stations (valves) which are watering similar landscape areas
together. For example, turf, flower beds, gardensthese different groups may
require individual watering schedules, or PROGRAMS
L Set the current time and correct day of the week. If odd or even day
watering is going to be used, make sure the current year, month and day of the
month is correct
® To select a different PROGRAM, press . Each press will move to the next
PROGRAM number. This is handy for quick reviewing of previously entered
information without losing your place in the programming cycle
Set Automatic Program
Set the automatic PROGRAM for each group of stations (valves) by completing
the following three steps:
1. Set watering START TIMES ® For each start time, all the stations (valves)
selected for the PROGRAM will come on in sequential order. If two start times
are set, the stations (valves) will come on twice
2. Set WATER DAYS
3. Set RUN TIME durations
This controller has been designed for quick intuitive programming. Remember
these simple tips for hassle free programming:
® One push of a button will increment one unit ® Holding a button down will
fast scroll through units ® During the programming, only flashing
units are able to be set ® Adjust flashing units using or ® Press or to scroll
through settings as desired ® The MAIN DIAL is the primary device
for selecting an operation ® Press to select different PROGRAMS. Each push
on this button will increment one PROGRAM number
Set Current Time, Day and Date
1. Turn the dial to DATE+TIME
2. Use or to adjust the flashing minutes
3. Press and then use or to adjust the flashing hours
® AM/PM must be set correctly.
4. Press and then use or to adjust the flashing days of the week
5. Press repeatedly until the calendar date appears on the display with the
year flashing
® The calendar only needs to be set when selecting odd/even day watering
6. Use or to adjust the year
7. Press and then use or to adjust the flashing month
8. Press and then use or to adjust the flashing date
® To return to the clock, turn the dial back to AUTO
5 of 20
Programming (continued)
Set Start Times
Set Watering Days
® All stations will run in sequential order for each start time
L For this example, we will set a START TIME for PROG No. 1
1. Turn the dial to START TIMES and ensure that PROG No. 1 is showing
® If not, press to cycle through the PROGRAMS and select PROG No. 1
2. START No. will be flashing
3. Use or to change the START No. if required
4. Press and the hours for your selected START No. will flash
5. Use or to adjust if required ® Ensure AM/PM is correct
6. Press and the minutes will flash
7. Use or to adjust if required ® Each PROGRAM can have up to 4 START TIMES
8. To set an additional START TIME, press and START No. 1 will flash
9. Advance to START No. 2 by pressing
10. Follow steps 4-7 above to set a START TIME for START No. 2
® To enable or disable a START TIME, use or to set both the hours and minutes
to zero
® To cycle through and change PROGRAMS, press repeatedly
L This unit has individual day, EVEN/ODD date, ODD-31 date and INTERVAL DAYS
selection
Individual Day Selection:
L Turn dial to WATER DAYS and PROG No. 1 will show 11. If not, use to select
PROG No. 1 12. MON (Monday) will be flashing 13. Use or to enable or disable
watering for Monday respectively 14. Use or to cycle through the days of the
week ® Active days will be shown with underneath
ODD/EVEN Date Selection
L Some regions only allow watering on odd dates if the house number is odd, or
likewise for even dates
L Turn dial to WATER DAYS and PROG No. 1 will show 15. Press repeatedly to
cycle past FRI until
ODD DAYS or EVEN DAYS is showing accordingly ® Press again for ODD-31 if
necessary ® The 365-day calendar must be set correctly for this
feature, (see Set Current Time, Day and Date) L This controller will take leap
years into account
Interval Day Selection
1. Turn dial to WATER DAYS and PROG No. 1 will show 2. Press repeatedly to
cycle past FRI until
INTERVAL DAYS is showing accordingly ® INTERVAL DAYS 1 will be flashing ® Use
or to select from 1 to 15 day intervals ® Example: INTERVAL DAYS 2 means the
controller will run the program in 2 days time ® The next active day is always
changed to 1,
meaning tomorrow is the first active day to run
6 of 20
Programming (continued)
Set Run Times
Set Additional Programs
® This is the length of time that each station (valve) is scheduled to water
on a particular program
® Maximum watering time is 12 hours 59 minutes for each station
® A station can be assigned to any or all of the possible 3 programs
1. Turn the dial to RUN TIMES
® Set schedules for up to 6 PROGRAMS by pressing when setting up START TIMES,
WATERING DAYS and RUN TIMES as previously outlined
L Although the controller will run automatic programs with the MAIN DIAL in
any position (with the exception of OFF), we recommend to leaving the main
dial on AUTO position when not programming or running manually
® STATION No. 1 will be flashing labelled as OFF, as shown above, meaning it
has no RUN TIME programmed in it
L The controller has permanent memory so when there is a power failure, even
if the battery is not installed, the programmed values will be restored to the
unit
2. Press or to select the station (valve) number
3. Press and OFF will flash
4. Press or to adjust the RUN TIME minutes as desired
5. Press and the RUN TIME hours will flash
6. Press or to adjust the RUN TIME hours as desired
7. Press and the STATION No. will flash again
8. Press or to select another station (valve), and repeat steps 2-7 above to
set a RUN TIME
® To turn a station OFF, set both the hours and minutes to 0, and the display
will flash OFF as shown above
L This completes the setup procedure for PROG No. 1
7 of 20
Manual Operation
Run a Single Station
® The maximum run time is 12 hours 59 minutes 1. Turn the dial to RUN STATION
® STATION No. 1 will be flashing ® The default manual run time is 10
minutesto edit
this, see Edit the Default Manual Run Time below 2. Use or to select the
desired station ® The selected station will start running and
the RUN TIME will decrease accordingly ® If there is a pump or master valve
connected,
PUMP A will be shown in the display, indicating the pump/master is active 3.
Press and the RUN TIME minutes will flash 4. Use or to adjust the minutes 5.
Press and the RUN TIME hours will flash 6. Use or to adjust the hours ® The
unit will revert to AUTO after the time has lapsed L If you forget to turn the
dial back to AUTO, the controller will still run programs 7. To stop watering
immediately, turn the dial to OFF
Edit the Default Manual Run Time
1. Turn the dial to RUN STATION ® STATION No. 1 will flash 2. Press and the
RUN TIME minutes will flash 3. Use or to adjust the RUN TIME minutes 4. Press
and the default RUN TIME hours will flash 5. Use or to adjust the RUN TIME
hours 6. Once the desired RUN TIME is set, press to
save this as the default manual RUN TIME L The new default will now always
appear
when the dial is turned to RUN STATION
Run a Program
1. To manually run a complete program or to stack multiple programs to run,
turn the dial to RUN PROGRAM
® OFF will flash on the display
2. To enable a PROGRAM, press and the display will change to ON
® If no RUN TIME has been set for the desired PROGRAM, the above step will not
work
3. To run the desired PROGRAM immediately, press
Stacking Programs
L There may be times when it is desirable to run more than one program
manually
L The controller allows this to occur using its unique facility of enabling a
program, before running it
L For example, to run PROG No. 1 and also PROG No. 2, the controller will
manage stacking of the programs so they do not overlap
1. Follow steps 1 and 2 of Run a Program to enable a single PROGRAM
2. To select the next PROGRAM press P
3. Enable the next PROGRAM by pressing ® To disable a program number, press
4. Repeat steps 2-3 above to enable additional PROGRAMS
5. Once all desired PROGRAMS have been enabled, they can be run by pressing
L The controller will now run all PROGRAMS that have been enabled in
sequential order
L This method can be used to enable any, or all of the available programs on
the controller.
® When running programs in this mode the BUDGET % will alter the RUN TIMES of
each individual station accordingly
8 of 20
Other Features
Stop Watering
® To stop an automatic or manual watering schedule, turn the dial to OFF
® For automatic watering remember to turn the dial back to AUTO, as OFF will
stop any future watering cycles from occurring
Rain Sensor
1. When installing a rain sensor, first remove the factory fitted link
between the C and R terminals as shown
Stacking Start Times
® Should you accidentally set the same START TIME on more than one PROGRAM,
the controller will stack them in sequential order
® All programmed START TIMES will be watered from the highest number first
Automatic Backup
L This product is fitted with permanent memory. This allows the controller to
hold all stowed values even in the absence of power sources, which means that
programmed information will never be lost
® Fitting a 9V battery is recommended to extend the life of the coin battery
but it will not provide sufficient power run the display
® If the battery is not fitted, the real time clock is backed up with a
lithium coin battery that has been factory fittedwhen the power returns the
clock will be restored to the current time
® It is recommended that the 9V battery is fitted and it is changed every 12
months
® The display will show FAULT BAT in the display when the battery has a week
left to runwhen this occurs, replace the battery as soon as possible
® If the AC power is off, the display will not be visible
2. Replace with the two wires from the rain sensor into these terminals,
polarity NOT required
3. Toggle the SENSOR switch to ON
4. Turn the dial to SENSOR to enable your rain sensor for individual stations
® The default mode is ON for all stations
® If a station is labelled ON on the display, this means your rain sensor will
be able to control the valve in the instance of rain
® Should you have a station that always needs to be watered, (such as an
enclosed greenhouse, or plants that are under cover) the rain sensor can be
turned OFF to continue watering during rainy conditions
5. To turn a station OFF, press to cycle through and select the desired
station, then press
6. To toggle a station back ON, press
® To disable the rain sensor and allow all stations to water, toggle the
SENSOR switch to OFF
WARNING!
KEEP NEW OR USED BUTTON/COIN BATTERIES OUT OF REACH OF CHILDREN
The battery can cause severe or fatal injuries in 2 hours or less if it is
swallowed or placed inside any part of the body. If you think batteries may
have been swallowed or placed inside any part of the body, seek immediate
medical attention
Contact the Australian Poisons Information Centre for 24/7 fast, expert
advice: 13 11 26
Refer to your local government guidelines on how to correctly dispose of
button/coin batteries.
Other Features (continued)
Rain Delay
Water Budgeting and Seasonal Adjustment
® To adjust the timing of your rain sensor, this controller features a RAIN
DELAY setting
L This allows a specific delay time to elapse after the rain sensor has dried
out before the station will water again.
1. Turn the dial to SENSOR
2. Press to access the RAIN DELAY screen ® The INTERVAL DAYS value will now
be flashing
3. Use or to alter the rain delay time in increments of 24 hours at a time
® A maximum delay of 9 days can be set
® Automatic station RUN TIMES can be adjusted by percentage as the seasons
change
L This will save valuable water as RUN TIMES can be adjusted quickly in
spring, summer, and autumn to reduce or increase water usage
® For this function, it is important to set the calendar correctlysee Set
Current Time, Day and Date for more details
1. Turn the dial to BUDGETthe display will appear as follows:
Pump Connection
L This unit will allow stations to be assigned to a pump ® The default
position is that all stations
are assigned to PUMP A 1. To change individual stations, turn the dial to PUMP
2. Press to cycle through each station 3. Use or to toggle PUMP A to
ON or OFF respectively
Display Contrast
1. To adjust the LCD contrast, turn the dial to PUMP 2. Press repeatedly
until the display reads CON 3. Use or to adjust the display contrast as
desired 4. To save your setting, turn the dial back to AUTO
L This means the RUN TIMES are set to a BUDGET% of 100%
L By default, the display will show the current MONTH
® For example, if STATION No. 1 is set to 10 minutes then it will run for 10
minutes
® If the BUDGET% changes to 50%, STATION No. 1 would now run for 5 minutes
(50% of 10 minutes
® The budget calculation is applied to all active STATIONS and RUN TIMES
2. Use or to cycle through the months 1 to 12
3. Use or to adjust the BUDGET% in 10% increments for each month
® This can be set for each month from OFF to 200%
L The permanent memory function will retain the information
4. To return to the clock, turn the dial to AUTO
5. If the BUDGET% for your current month is not 100%, this will be shown in
the AUTO clock display
10 of 20
Other Features (continued)
Fault Indication Feature
Clearing the Programs
L This unit has a M205 1AMP glass fuse to protect the transformer from power
surges, and an electronic fuse to protect the circuit from field or valve
faults
The following fault indications can be displayed:
NO AC: Not connected to mains power or transformer not working
As this unit has a permanent memory feature, the best way to clear the
PROGRAMS is as follows:
3. Turn the dial to OFF 4. Press twice until the display appears as follows:
FAULT BAT: 9V battery not connected or needs to be replaced
System Test
1. Turn the dial to TEST STATIONS ® The system test will begin automatically
L Your PRO469 will water every station
sequentially for 2 minutes each
2. Press to advance to the next station before the 2 minute period has
elapsed
® It is not possible to go backwards to a previous station
® To restart the system test from STATION No. 1, turn the dial to OFF, and
then back to TEST STATIONS
5. Press to clear all PROGRAMS ® The clock will be retained, and the other
functions for setting START TIMES, WATERING DAYS and RUN TIMES will be cleared
and returned to the start up settings ® PROGRAMS can also be cleared by
manually setting START TIMES, WATERING DAYS and RUN TIMES individually back to
their defaults
Program Rescue Feature
1. To upload Program Recall Feature turn the dial to OFF and press and
simultaneously LOAD UP will appear on the screen
2. Press to complete the process ® To re-install Program Recall Feature
turn the dial OFF and press ® LOAD will appear on the screen ® Press to return
to the original stored program
11 of 20
Installation
Mounting the Controller
® Install the controller near a 240VAC outletpreferably in a house, garage,
or exterior electrical cubicle
® For ease of operation, eye level placement is recommended
® Ideally, your controller location should not be exposed to rain or areas
prone to flooding or heavy water
® This inbuilt controller comes with an internal transformer and is suitable
for outdoor or indoor installation
® The housing is designed for outdoor installation but the plug needs to be
installed in a weatherproof socket or under cover
® Fasten the controller using the key hole slot positioned externally on the
top centre and the additional holes positioned internally under the terminal
cover
Electrical Hook-up
All electrical work must be carried out in accordance with these instructions,
following all applicable local, state and federal codes pertaining to the
country of installationfailure to do so will void the controller’s warranty
Disconnect mains power supply before any maintenance work to the controller or
valves is undertaken
Do not attempt to wire any high voltage items yourself, i.e. pumps and pump
contactors or hard wiring the controller power supply to the mainsthis is the
field of a licensed electrician
Serious injury or death could result from improper hook upif in doubt consult
your regulatory body as to what is required
Field Wiring Connections
1. Prepare wire for hook-up by cutting the wires to the correct length and
stripping approximately 0.25 inches (6.0mm) of insulation from the end to be
connected to the controller
2. Ensure terminal block screws are loosened sufficiently to permit easy
access for wire ends
3. Insert stripped wire ends into the clamp aperture and tighten screws
® Do not over tighten as this may damage the terminal block
® A maximum of 0.75 amps may be supplied by any output
4. Check the inrush current of your solenoid coils before connecting more
than two valves to any one station
Power Supply Connections
® It is recommended that the transformer is not connected to a 240VAC supply
which is also servicing or supplying motors (such as air conditioners, pool
pumps, refrigerators)
® Lighting circuits are suitable as power sources
12 of 20
Installation (continued)
Terminal Block Layout
24VAC C R M 1 2 3 4 5 6 7 8 9
1. 24VAC 2. COM 3. SENS
24VAC power supply connection Common wire connection to field wiring Input for rain switch
4. PUMP 1 Master valve or pump start output 5. ST1ST9 Station (valve) field connections ® Use a 2 amp fuse
Valve Installation and Power Supply Connection
® The purpose of the master valve is to shut off the water supply to the
irrigation system when there is a faulty valve or none of the stations are
operating correctly
® It is used like a back-up valve or fail safe device and is installed at the
start of the irrigation system where it is connected to the water supply line
13 of 20
Installation (continued)
Station Valve Installation
® Up to two 24VAC solenoid valves can be connected to each station output and
wired back to the Common (C) connector
® With long cable lengths, voltage drop can be significant, especially when
more than one coil is wired to a station
® As a good rule of thumb select your cable as follows: 050m cable dia 0.5mm
L 50100m cable dia 1.0mm
L 100200m cable dia 1.5mm
L 200400m cable dia 2.0mm
® When using multiple valves per station, the common wire needs to be larger
to carry more current. In these circumstances choose a common cable one or two
sizes larger than required
® When making connections in the field, only ever use gel filled or greased
filled connectors. Most field failures occur due to poor connections. The
better the connection here, and the better the waterproof seal the longer the
system will perform without trouble
® To install a rain sensor, wire it between the Common (C) and the Rain Sensor
(R) terminals as shown
24VAC C R M 1 2 3 4 5 6 7 8 9
RAIN
M SENSOR:
OPTIONAL
3
1
6
2
4
7
C
8
9
5
14 of 20
Installation (continued)
Pump Start Relay Connection
L This controller does not provide mains power to drive a pumpa pump must be
driven via an external relay and contactor setup.
L The controller provides a low voltage signal that actuates the relay which
in turn enables the contactor and finally the pump
Pump Protection (System Test)
® Although the controller has permanent memory and thus a default program will
not cause erroneous valve actuation as in some controllers, it is still good
practice when using a system where the water supply comes from a pump to
connect unused stations on the unit back to the last used station
® This in effect, inhibits the chances of the pump ever running against a
closed head
L In some circumstances not all operational stations may be hooked upfor
example, if the controller was capable of running 6 stations but there were
only 4 field wires and solenoid valves available for connection
® This situation can pose a risk to a pump when the system test routine for
the controller is initiated
® The system test routine sequences through all available stations on the
controller
® In the above example this would mean stations 5 through to 6 would become
active and would cause the pump to operate against a closed head
This could possibly cause permanent pump, pipe and pressure vessel damage
® It is mandatory if the system test routine is going to be used, that all
unused, spare stations, should be linked together and then looped to the last
working station with a valve on it
® Using this example, the connector block should be wired as per the diagram
below
Single Phase Pump Installation ® It is recommended to always use a relay between the controller and the pump starter
24VAC C R M 1 2 3 4 5 6 7 8 9
CM1 2 3 4
PUMP MOTOR MAGNETIC STARTER
24VAC AC RELAY
POWER SUPPLY
15 of 20
Troubleshooting
Symptom
Possible Cause
Suggestion
No display
Faulty transformer or blown fuse
Check fuse, check field wiring, check transformer
Single station not working
Faulty solenoid coil, or break in field wire Check fault indicator in display
Check solenoid coil (a good solenoid coil should read around 33ohms on a multi meter). Test field cable for continuity. Test Common cable for continuity
No automatic start
Programming error or blown fuse or transformer
If unit works manually then check the programming. If not then check the fuse, wiring and transformer.
Buttons not responding
Short on button or programming not correct. Unit may be in sleep mode and no AC power
Check instruction book to ensure programming is correct. If buttons still not responding then return panel to supplier or manufacturer
System coming on at random
Too many start times entered on automatic programs
Check number of start times entered on each program. All stations will run once for every start. If fault persists return panel to supplier
Multiple stations running at once
Possible faulty driver triac
Check wiring and swap faulty station wire’s on the controller terminal block with known working stations. If the same outputs are still locked on, return panel to supplier or manufacturer
Pump start chattering
Faulty relay or pump contactor
Electrician to check voltage on relay or contactor
Display cracked or missing segments
Display damaged during transportation
Return panel to supplier or manufacturer
Sensor input not working
Slide switch on front panel to the
Sensor enable switch in the OFF position or faulty wiring
ON position, test all wiring and make sure the sensor is a normally closed type. Check programming
to make sure sensor is enabled
Pump not working on a specific station or program
Programming error with pump enable routine
Check programming, using the manual as a reference and correct mistakes
16 of 20
Electrical Specifications
Electrical Outputs
Overload Protection
Power Supply
L Mains supply: This unit runs off a 240 volt 50 hertz single phase outlet
L The controller draws 30 watt at 240VAC L The internal transformer reduces
the 240VAC
to an extra low voltage supply of 24VAC L The internal transformer is fully
compliant
with AS/NZS 61558-2-6 and has been independently tested and judged to comply L
This unit has a 1.25AMP low energy, high efficient toroidal transformer for
long life performance
Electrical Power Supply:
L Input 24 volts 50/60Hz
Electrical Outputs:
L Maximum of 1.0 amp
L Standard 20mm M-205 1 amp fast blow glass fuse, protects against power
surges and electronic fuse rated to 1AMP protects against field faults
L Faulty station skip function
Power Failure
L The controller has permanent memory and real time clock, so the data is
always backed up even with the absence of all power
L The unit is factory fitted with a 3V CR2032 lithium battery with up to 10
years memory backup
L The 9V alkaline battery maintains the data during power outages, and is
recommended to help maintain the life of the lithium battery
Tampering with the unit will void the warranty ® The batteries do not run the
outputs. The internal
transformer requires mains power to run the valves
To Solenoid Valves:
Wiring
L 24VAC 50/60Hz 0.75 amps max ® Up to 2 valves per station on the inbuilt model
® Output circuits should be installed and protected in accordance with wiring code for your location
To the Master Valve/Pump Start:
L 24VAC 0.25 amps max ® Transformer and fuse capacity must be
compatible with output requirements
17 of 20
Servicing
Servicing your Controller The controller should always be serviced by an
authorised agent. Follow these steps to return your unit: 1. Turn the mains
power off to the controller ® If the controller is hard-wired, a qualified
electrician will be required to remove the entire unit, depending on the fault
2. Proceed to either unplug and return the entire controller with transformer
or
disconnect the panel assembly only for servicing or repair 3. Disconnect the
24VAC leads at the controller 24VAC terminals on the very left hand side of
the terminal block 4. Clearly mark or identify all valve wires according to
the terminals they are connected to, (19) ® This allows you to easily wire
them back to the controller, maintaining your valve watering scheme 5.
Disconnect valve wires from the terminal block 6. Remove the complete panel
from the controller housing by unscrewing the two screws
in the lower corners of the fascia (both ends of the terminal block) 7. Remove
the complete controller from the wall unplugging the lead 8. Carefully wrap
the panel or controller in protective wrapping and pack in a
suitable box and return to your service agent or the manufacturer Tampering
with the unit will void the warranty. 9. Replace your controller panel by
reversing this procedure. ® The controller should always be serviced by an
authorised agent
18 of 20
Warranty
3 Year Replacement Guarantee Holman offers a 3 year replacement guarantee with
this product. In Australia our goods come with guarantees that cannot be
excluded under the Australian Consumer Law. You are entitled to a replacement
or refund for a major failure and compensation for any other reasonably
foreseeable loss or damage. You are also entitled to have the goods repaired
or replaced if the goods fail to be of acceptable quality and the failure does
not amount to a major failure. As well as your statutory rights referred to
above and any other rights and remedies you have under any other laws relating
to your Holman product, we also provide you with a Holman guarantee. Holman
guarantees this product against defects caused by faulty workmanship and
materials for 3 years domestic use from the date of purchase. During this
guarantee period Holman will replace any defective product. Packaging and
instructions may not be replaced unless faulty. In the event of a product
being replaced during the guarantee period, the guarantee on the replacement
product will expire 3 years from the purchase date of the original product,
not 3 years from the date of replacement. To the extent permitted by law, this
Holman Replacement Guarantee excludes liability for consequential loss or any
other loss or damage caused to property of persons arising from any cause
whatsoever. It also excludes defects caused by the product not being used in
accordance with instructions, accidental damage, misuse, or being tampered
with by unauthorised persons, excludes normal wear and tear and does not cover
the cost of claiming under the warranty or transporting the goods to and from
the place of purchase. Should you suspect your product may be defective and
need some clarification or advice please contact us directly: 1300 716 188
support@holmanindustries.com.au 11 Walters Drive, Osborne Park 6017 WA If you
are certain your product is defective and is covered by the terms of this
warranty, you will need to present your defective product and your purchase
receipt as proof of purchase to the place you purchased it from, where the
retailer will replace the product for you on our behalf.
19 of 20
Thanks for being a #SMARTGARDENER
We really appreciate having you as a customer, and would like to say thank you
for choosing us. We recommend registering your new product on our website.
This will ensure we have a copy of your purchase and activate an extended
warranty. Keep up to date to with relevant product information and special
offers available through our newsletter.
www.holmanindustries.com.au/product-registration/ Thanks again for choosing
Holman