hama 00186355 EWS-800 Weather Station Instruction Manual

June 6, 2024
Hama

hama logo

hama 00186355 EWS-800 Weather Station

Operating instruction

Controls and Displays

A. Base station

hama 00186355 EWS-800 Weather Station-1

  1. Weather forecast symbol

  2. Minimum/maximum data

  3. Atmospheric pressure trend

  4. Low (LO)/high (HI) atmospheric pressure alarm

  5. Atmospheric pressure value

  6. Low (LO)/high (HI) atmospheric pressure alarm, active

  7. Relative/absolute atmospheric pressure

  8. 24 hour (atmospheric pressure history)

  9. Atmospheric pressure unit

  10. Low (LO)/high (HI) room temperature/room humidity alarm,active

  11. 11. Low (LO)/high (HI) room temperature/room humidity alarm

  12. Room temperature

  13. Room temperature unit

  14. Relative room humidity

  15. Low (LO)/high (HI) outdoor temperature/outdoor humidity alarm, active

  16. Outdoor temperature/outdoor humidity lower (LO)/higher (HI) alarm

  17. Outdoor temperature unit

  18. Outdoor temperature/dew point temperature

  19. Outdoor transmitter signal

  20. Relative outdoor humidity

  21. Date

  22. Summertime

  23. DCF-controlled time

  24. Time

  25. Weekday

  26. Alarm time, active

  27. Wireless symbol

  28. SET button =switching display mode/confirmation of set value

  29. ALM button =displaying/setting/deactivating/activating the alarm functions

  30. MIN/MAX button =accessing the saved maximum/minimum values/reduction of the current set value

  31. + button =increasing the current set value

  32. SNOOZE /LIGHT button =stopping the alarm/activating the backlight (approx. 10 seconds)/stopping Settings

  33. Opening for wall mounting

  34. Battery compartment

  35. Base
    B.Measuring stationhama 00186355 EWS-800 Weather
Station-2

  36. Outdoor temperature

  37. Outdoor humidity

  38. Battery compartment

  39. Opening for wall mounting

  40. TX button =not used

  41. C/F button =switching between°C and°F

Thank you for choosing aHama product.
Take your time and read the following instructions and information completely.Please keep these instructions in asafe place for futurereference. If you sellthe device, please pass these operating instructions on to the new owner.

Explanation of Warning Symbols and Notes


Warning
This symbol is used to indicate safety instructions or to draw your attention to specific hazards and risks.


Note
This symbol is used to indicate additional information or important notes.

Package Contents

  • Weather station EWS-800 (base station for indoors /outdoor measuring station)
  • These operating instructions

Safety Notes

  • The product is intended for private, non-commercial use only.
  • Do not operate the product outside the power limits given in the specifications.
  • Do not use the product in moist environments and avoid splashes.
  • Do not use the product in the immediate vicinity of heaters or other heat sources or in direct sunlight.
  • Do not use the product in areas where the use of electronic devices is not permitted.
  • Only connect the product to a socket that has been approved for the device. The socket must be installed close to the product and easily accessible.
  • Do not drop the product and do not expose it to any major shocks.
  • Do not open the device or continue to operate it if it becomes damaged.
  • Do not attempt to service or repair the product yourself. Leave any and all service work to qualified experts.
  • Keep the packaging material out of the reach of children due to the risk of suffocation.
  • Dispose of packaging material immediately according to locally applicable regulations.
  • Do not modify the product in any way.Doing so voids the warranty.
  • Use the product for its intended purpose only.

Warning –Batteries

  • When inserting batteries, note the correct polarity (+ and -markings) and insert the batteries accordingly. Failure to do so could result in the batteries leaking or exploding.
  • Only use batteries (or rechargeable batteries) that match the specified type.
  • Before you insert the batteries, clean the battery contacts and the polar contacts.
  • Do not allow children to change batteries without supervision.
  • Do not mix old and new batteries or batteries of a different type or make.
  • Remove the batteries from products that are not being used for an extended period (unless these are being kept ready for an emergency).
  • Do not short-circuit batteries.
  •  Do not charge batteries.
  • Donot throw batteries in a fire.
  • Keep batteries out of the reach of children.
  • Never open, damage, or swallow batteries or allow them to enter the environment. They can contain toxic, environmentally harmful heavy metals.
  • Immediately remove and dispose of dead batteries from the product.
  • Avoid storing, charging, or using the device in extreme temperatures and extremely low atmospheric pressure(for example, at high altitudes).

Getting Started

Measuring station

  • Unscrew the screw on the battery compartment (38) on the back of the measuring station and open it.
  • Insert two AAA batteries and close the battery compartment (38) and then secure the screw again.

Note
Before use, ensure you insert the batteries in the measuring station first and then in the base station.

Base station

  • Open the battery compartment (34) and insert three AA batteries with the correct polarity into the battery compartment. Close the battery compartment.

Installation

Note –Installation

  • We recommend initially placing the base and measuring stations in the intended locations without installing them and making all the settings described in 6. Operating the Base Station
  • Only install the stations once the appropriate settings have been made and astable wireless connection is established.

Note

  • The wireless transmission range between the measuring and base stations is up to 100 min open spaces. Before installation, ensure that wireless transmission will not be disrupted by interference or obstacles like buildings, trees, vehicles, high-voltage lines, etc.
  • Beforethe final installation, ensure that there is sufficient reception between the intended installation locations.
  • When installing the measuring station, ensure that it is protected from direct sunlight and rain.
  • The international standard height for measuring air temperatureis1.25 m(4ft) above ground.

Warning

  • Buy special or suitable installation material from a specialized dealer for wall-mounting.
  • Ensurethat no faulty or damaged parts are installed.
  • Never apply force during mounting. This could damage the product.
  • Before mounting, ensure that the chosen wall is suitable for the weight to be mounted, and make sure that there are no electrical wires, water, gas or other lines at the installation site on the wall.
  • Do not mount the product above locations where persons might linger.

Base station

  • Use the base (35) to position the base station on a level surface.
  • Alternatively, you can install the base station on a wall using the opening (33) on the back.

Measuring station

  • You can also position the measuring station on a level outdoor surface using the base.
  • Werecommend installing the measuring station securely on an outdoor wall.
  • Install an anchor, screw, nail, etc. in the wall of your choice.
  • Hang up the base/measuring station using the opening (33/39) intended for this purpose.

Operating the Base Station

Note –Input
Hold down the MIN/MAX button (30) or the + button (31) to select the values faster.

If you press the SNOOZE /LIGHT button (32), the display will light up for approx. 10 seconds.

Automatic initial setup
All available LCDsegments on the display are displayed briefly after turning the measuring station on for the first time.

  • The base station then performs an automatic initial setup. During setup, the base station performs measuring station synchronization, the pressure measurement values are stabilised and factory settings are set.

Note –Initial setup

  • Initial setup takes approx. 3minutes.
  • Donot press any buttons during setup. Otherwise, values may not be transmitted correctly and there is a risk of value errors and inaccuracies.
  • The setup process is completed when the indoor (12, 14) and outdoor (18, 20) measurement data is displayed
  • After the first time, the base station is switched on and successful transmission is established between the base station and the measuring station, the clock will automatically search for aDCF signal. During the search, the wireless symbol (27) will flash.

hama 00186355 EWS-800 Weather Station-5

Note –Time settings

  • If, During the first minute of the initial setup, no DCF signal can be found, the search is stopped and repeated every two hours. The wireless symbol will go out.
  • You can, however,set the time and the date manually.
  • The clock automatically continues to search for the DCF signal on a daily basis. If the signal is received successfully, the manually-set time and date are overwritten.

Note –Summertime
The clock automatically switches to summertime. appears on the display as long as summertime is activated.

Basic and manual settings

  • Press and hold the SET button (28) for approx. 3seconds to make the following settings one after the other:
  • Time zone (24)
  • 12/24 hour format (24)
  • Hours (24)
  • Minutes (24)
  • Year (21)
  • Month (21)
  • Day (21)
  • Temperatureunit (°C /°F) (13+17)
  • Room temperature value (12)
  • Room humidity value (14)
  • Outdoor temperature value (18)
  • Outdoor humidity value (20)
  • Atmospheric pressure unit (hPa/inHg) (5+9)
  • Relative atmospheric pressure reference value (5)
  • Atmospheric pressure threshold value (5)
  • Storm threshold value (5)
  • To select the individual values, press the MIN/MAX button (30) or the + button (31) and confirm each selection by pressing the SET button (28).
  • Press the SET button (28) to adopt the set value displayed and to skip.
  • Ifyou do not make an entry for 20 seconds, you automatically exit setup mode. Alternatively, press the SNOOZE /LIGHT button (32) to exit setup mode before selecting all the values.

Note –Time zone

  • The DCF signal can be received over a wide range, but always corresponds to the applicable Central European Time in Germany. Make sure you account for the time difference in countries with another time zone.
  • If you are in Moscow,the time is 3hours later than in Germany. This means that you should set +3 for the time zone. The clock then automatically sets itself 3hours ahead after receiving the DCF signal or according to the manually set time.

Note –Temperature and humidity

  • In terms of accuracy, the temperature and air humidity measurement is intended for private, non-commercial use. Individual cases, the measured values displayed may differ slightly from comparison values, e.g. values from a calibrated measuring device. Using the Basic and manual settings, you can adjust and recalibrate the values for the room/outdoor temperature and/or the humidity.
  • We recommend that you do not manually calibrate the measured values, press the SET button (28) during manual setup to skip this step.

Note –Atmospheric pressure

  • The absolute atmospheric pressure(abs)is a value measured at the installation location that cannot be changed.
  • The relative atmospheric pressure(rel)is the absolute atmospheric pressure at the installation location corrected to the atmospheric pressure at sea level (msl).
  • The reference value for relative atmospheric pressure is set to 1013.2 hPaasstandard. For an exact measurement, adapt the reference value to your location. You can manually set the reference value to within arangeof919.0 hPaand 1080.0 hPa.
  • Information on the current relative atmospheric pressure for you location is available on the Internet, from your local meteorological office, on the radio, etc.

Note –Atmospheric pressure threshold value

  • The weather forecast is based on atmospheric pressure changes, and you individually set their threshold values between 2hPa and 4hPa.The threshold value is set to 3hPA as standard.

  • Adecrease or increase in the atmospheric pressure by at least the set threshold value is registered as a change in the weather.
     For locations with frequent changes in atmospheric pressure, we recommend you set a higher atmospheric threshold value than for locations with a relatively constant atmospheric pressure.
    Note –Storm threshold value

  • The storm forecast is also based on atmospheric pressure changes, and you individually set their threshold values between 3hPa and 9hPa.The threshold value is set to 6hPA as standard.

  • The storm warning display is activated if, over a period of three hours, there is a decrease or increase in the atmospheric pressure by a tleast the set threshold value.

  • When the storm warning display is activated, the rain symbol and the trend arrow flash for three hours.

Weather forecast

  • Based on changes in the atmospheric pressure and the data saved, the base station is able to make weather forecasts for the next 12 to 24 hours.

Note –Weather forecast

  • The weather forecast function is not available during the first few hours of operation because it requires data that is collected during operation.
    The weather forecast and the current weather are indicated by four different symbols (1):hama 00186355 EWS-800 Weather Station-6

  • Based on the measured barometer values, the atmospheric pressure trend for the next few hours is displayed between the weather forecast symbols.hama 00186355 EWS-800 Weather Station-7

  • The weather symbols change depending on the current relative atmospheric pressure and atmospheric pressure changes within the past six hours. If the weather is changing, the atmospheric pressure trend arrows (3) flash for three hours to indicate the change in weather.The arrows (3) stop flashing when the weather conditions have subsequently stabilized and the station has not detected any further changes in weather.
    Examples:hama 00186355 EWS-800 Weather Station-8

  • The bar graph (8) shows the history of the relative atmospheric pressure within the last 24 hours.

Temperature /atmospheric pressure display mode

  • Press the SET button (28) repeatedly to change between the following displays:

  • Outdoor temperature(18: TEMP)/ Dew point temperature (18: DEWPOINT)

  • Absolute atmospheric pressure(7: abs)/Relative atmospheric pressure(7: rel)
    The applicable display begins to flash.

  • While the display is flashing, press the MIN/MAX button (30) or the + button (31) to switch between the outdoor temperature and the dew point or between the absolute and relative atmospheric pressure.

  • Confirm your display selection by pressing the SET button (28).
    The weather station offers you the option to adjust the relative air pressure display according to the height of the location above sea level.
    To set /calibrate the relative air pressure, proceed as follows:

  • Press and hold the SET button (28) until the time at the bottom edge of the display disappears.

  • Now press the SET button (28) several times until “rel”appears next to air pressure and the numeric value for the air pressure flashes.

  • Now use MIN/MAX (30) or + (31) to adjust the (current) relative value in 0.1 increments. Use the value from a calibrated weather station nearby or the value from a weather service to set the value for the relative air pressure.

Note –Dew point

  • The dew point temperature indicates avalue to which, with the current humidity level, the outside temperature would have to increase/decrease in order to reach 100% relative humidity.
    Alarm mode

  • Repeatedly press the ALM button (29) to access HI AL
    (4/11/16/21) or LO AL (4/11/16/21) alarm mode.

  • Inalarm mode HI AL (4/11/16/21), repeatedly press the SET button (28) to switch between the following alarm functions:

    • Alarm (hour/minute) (24)
    • High room humidity alarm (14)
    • High room temperature alarm (12)
    • High outside humidity alarm (20)
    • High outdoor temperature alarm (18)
    • High absolute atmospheric pressure alarm (5)
      The applicable display begins to flash.
  • In alarm mode LO AL (4/11/16/21), repeatedly press the SET button (28) to switch between the following alarm functions:

  • Alarm (hour/minute) (24)

  • Lowroomhumidity alarm (14)

  • Lowroomtemperaturealarm (12)

  • Low outside humidity alarm (20)

  • Low outdoor temperature alarm (18)

  • Low absolute atmospheric pressure alarm (5)
    The applicable display begins to flash.

  • In the corresponding display, press the MIN/MAX button (30) or the + button (31) to change the alarm value, and confirm your selection by pressing the SET button (28).

  • In the corresponding display, press the ALM button (29) to activate/deactivate the corresponding alarm function.

  • If the alarm is activated, the corresponding symbol (6/10/15/26), HI AL (4/11/16) and/or LO AL (4/11/16) is displayed.

  • If you do not make an entry for 20 seconds, you automatically exit setup mode. Alternatively, press the SNOOZE /LIGHT button (32) to exit setup mode before selecting all the values.
    Note

  • The set value is displayed for alarms that are already set, deactivated alarms are indicated by — or –.

  • The corresponding alarm triggers when the weather conditions or the time reaches the set values for an active alarm. An alarm will sound and the corresponding symbols (6/10/15/26), HI AL (4/11/16) and/or LO AL (4/11/16) and the alarm value will flash for 2 minutes.

  • Press any button to stop the alarm.
    Note –Alarm due to weather conditions

  • The alarm signal does not sound again if the same alarm function is triggered again within 10 minutes. The symbol and the alarm value flash so long until the weather conditions have stabilized.

  • The alarm is automatically triggered again if the weather conditions exceed or fall below the set alarm value.

  • If the dew point temperature triggers the low/high outdoor temperature alarm, the DEW POINT symbol also begins to flash.

Note –Snooze function
While the alarm signal is sounding, press the SNOOZE /LIGHT button (32) to activate the snooze function. The alarm signal will be stopped for 5minutes, after which it will sound again. The corresponding alarm symbol will start to flash.

Maximum and minimum temperature and humidity values

  • The base station automatically stores the maximum and minimum temperature and humidity values.
  • Repeatedly press the MIN/MAX button (30) to switch between the current temperature and humidity, minimum temperature and humidity (2: MIN)and the maximum temperature and humidity (2: MAX).
  • In the maximum value display (2: MAX), repeatedly press the + button (31) to display the following values with the date (21) and time (24) they were recorded.
    • Maximum room humidity (14)
    • Maximum room temperature(12)
    • Maximum outdoor humidity (20)
    • Maximum outdoor temperature(18)
    • Maximum absolute/ relative atmospheric pressure(5)
  • In the minimum value display (2: MIN), repeatedly press the + button (31) to display the following values with the date (21) and time (24) they were recorded.
    • Minimum room humidity (14)
    • Minimum room temperature(12)
    • Minimum outdoor humidity (20)
    • Minimum outdoor temperature(18)
    • Minimum absolute/ relative atmospheric pressure(5)
  • In the individual maximum and minimum value display, press the SET button (28) for approx. 3seconds to delete the corresponding values with the date (21) and time (24) they were recorded.
     Press the SNOOZE /LIGHT button (32), or wait for approx. 20 seconds to return to the display of the current measurement values.

Note –Replacing the batteries
Note, the stations have to be resynchronized each time after you change the batteries in the measuring or base station. To do this, remove the batteries from the other station and then reinsert them, or change them as required.

Note –Faulty transfer of measured values
In isolated cases, interference—e.g. from a WLAN network,
computer or a television set—can cause the transfer of measured values between the measuring station and the base station to fail.
In this case, you must resynchronize the stations by briefly removing the batteries from both stations and reinserting them. If the measured values are not transferred again once the batteries are inserted, replace the batteries with new ones.
If necessary, select a new location for the base station in order to avoid possible interference in the future.

Care and Maintenance

Only clean this product with a slightly damp, lint-free cloth and do not use aggressive cleaning agents. Make sure that water does not get into the product.

Warranty Disclaimer
Hama GmbH &CoKG assumes no liability and provides no warranty for damage resulting from improper installation/mounting, improper use of the product or from failure to observe the operating instructions and/or safety notes.

Technical Data

| Basisstation| Messstation
---|---|---
Stromversorgung| 4,5 V

3x AA Batterie

| 3,0 V

2x AAA Batterie

Messbereich

Temperatur Luftfeuchtigkeit

| 0°C – +50°C/ 32°F– 122°F

20%– 95%

| -20°C – +60°C/ -4°F – 140°F 20% – 95%
Messschritte

Temperatur Luftfeuchtigkeit

| 0,1°C / 0,2°F

1%

| 0,1°C / 0,2°F

1%

Messzyklus Temperatur/ Luftfeuchtigkeit| 30 s| 57 s
Messbereich Barometer


Messschritte

| 919 – 1080 mbar/hPa

(27,14 – 31,89 inHg)

0,1 hPa

| –
DCF-Funkuhr| Ja| Nein
Hygrometer| Ja| Ja
Thermometer| Ja| Ja
Barometer| Ja| Nein
Weckfunktion| Ja| Nein
Frequenz| 433 MHz
Reichweite| ≤ 100 m

Declaration of Conformity
Hereby,Hama GmbH &CoKG declares that the radio equipment type [00076045, 00186355] is in compliance with Directive 2014/53/EU.The full text of the EU declaration of conformity is available at the following internet address: www.hama.com -> 00076045, 00186355 -> Downloads.

Frequenzband/Frequenzbänder 433 MHz
Abgestrahlte maximale Sendeleistung 0,107mW

Hama GmbH &CoKG 86652 Monheim /Germany
Service &Support
www.hama.com
+49 9091 502-0
All listed brands are trademarks of the corresponding companies. Errors and omissions excepted, and subject to technical changes. Our general terms of delivery and payment are applied.