Spray Additives

a. Push down on the GRAB HANDLE (M)
b. Twist counter-clockwise to unhook the GRAB HANDLE from the PRESSURE TANK (E)
c. Pull the GRAB HANDLE out of the PRESSURE TANK
d. Place the GRAB HANDLE somewhere clean to avoid dirt touching the lubricated PLUNGER (N)
e. Add fertiliser or other additives to your EzySpray® before filling with water
f. Optional: To include more additive, insert the plunger to push the first shot into the tank
g. Optional: For powder additives, include a cup of water in addition to the additive
h. Repeat Steps 4c and d as necessary to introduce more additive

HOLMAN GC8030 EzySpray 3L Pump Free Garden Sprayer -
parts

Introducing Spray Additives

Ensure the SPRAY HOSE (D) is attached when removing or replacing the GRAB HANDLE to avoid excess additive or water squirting out of the PRESSURE TANK outlet After removing the GRAB HANDLE, follow your additive instructions to pour the correct  amount into the TANK OPENING (O)

|
---|---

j. Insert the PLUNGER into the TANK OPENING, in the position shown above, push down and rotate clockwise to hook the GRAB HANDLE back into place
k. Follow Tank Filling in Step 5 to fill the tank with water and mix in the additive

Tank Filling

Tank Filling
Min. tap pressure required to fill tank: 300kPa

a. Before filling your EzySpray®, push excess air from your garden hose by turning on the tap
This will stop additional air using the EzySpray® capacity
b. Once water is flowing out, you can turn off the tap
c. Locate the 12mm snap-on HOSE CONNECTION (K)
d. Attach the INLET VALVE CONNECTOR (P)
e. Add a standard 12mm garden hose (Q) onto this connection
f. Ensure the INLET VALVE (P) is open and turn the garden hose tap on begin filling
Watch the pressure gauge as the reservoir fills with water
The gauge should begin moving towards MAX level
g. If your water source is high pressure, it may trigger the PRESSURE RELEASE VALVE (L) when full to stop your EzySpray from over-pressurising:

h. If your water source is low pressure, the EzySpray® will stop filling when it reaches the maximum pressure
i. Once your EzySpray is full, turn off your tap and close the INLET VALVE (P)
j. Disconnect the INLET VALVE (P) and garden hose L High or low pressure circumstances are fine and shouldn’t damage your EzySpray®
Watch for excess water from the hose when disconnectingHOLMAN GC8030
EzySpray 3L Pump Free Garden Sprayer - MAX 2

Spraying

Spray Functions
The SPRAY HEAD (A) includes 4 individual spray functions: JET, CONE, SHOWER and MIST
a. Before spraying, twist the orange section of the SPRAYHEAD to select the desired spray pattern

Trigger Action
b. To begin spraying, simply point the SPRAY HEAD in the desired direction and pull the orange TRIGGER (C) lever

Troubleshooting

Question
Why won’t my EzySpray® work?
Why is the pressure gauge reading below 1 bar?

Answer

Your EzySpray® may need to be re-pressurised:
This is only necessary if the pressure is below 1 bar. It should be able to hold this minimum pressure for an extended period

a. Locate SCHRADER (bike) VALVE (J) on the opposite side to the GAUGE(I)
b. Unscrew the lid off the valve
c. Attach a standard bike pump
d. Pump air in until the gauge reads at least 1 bar

Check the PRESSURE GAUGE (I) to ensure water is in the tank
Check hose for kinks and blockages
Check wand for blockages
Try each setting on the spray head and check this for blockages

Why is the pressure release valve triggered and spraying water during filling?

This is perfectly normal and means the tank is full of water
Turn off your tap and disconnect your garden hose

Flushing and Cleaning

Spray Functions
It is important to completely flush your EzySpray® with clean water when finished with chemical spraying

a. After you have completed your spraying job and the tank has run out, connect to a tap and refill the tank with clean water
b. Point your spray wand into a bucket or anywhere you don’t mind the excess fluid flowing
c. Hold down the trigger and let the contents flow through until the tank is empty
d. Once the tank is empty, we recommend storing your EzySpray® in a dry, protected space out of direct sunlight
Don’t leave full for extended periods of time!

Question Answer
Why is my EzySpray®  hose difficult to screw onto the tank and wand? The hose

included with your EzySpray®  is designed for the best seal  possible, which may be difficult to screw on during initial assembly
For the easiest assembly, screw the hose onto the tank outlet before  screwing onto the spray wand
Why has the pressure
gauge stopped rising while
filling with water?| The EzySpray®  can still be used when not entirely full
It may be due  to a low-pressure water source–try filling the tank elsewhere with  higher water pressure
Why doesn’t my garden hose
fit on my EzySpray® ?| Your hose may be 18mm
Unscrew the 12mm hose connection and  replace with an 18mm version
Visit www.holmanindustries.com.au/product/18mmbrass-sprinkler- adaptor for more info
How do I empty my EzySpray®?| Point your spray wand anywhere you don’t mind the excess fluid  flowing
Hold the trigger and let the contents spray until the tank is  empty

HOLMAN GC8030 EzySpray 3L Pump Free Garden Sprayer - pressure
3

We really appreciate having you as a customer, and would like to say thank you for choosing us.
We recommend registering your new product on our website. This will ensure we have a copy of your purchase and will activate an extended warranty. Keep up to date to with relevant product information and special offers available through our newsletter.

www.holmanindustries.com.au/product- registration/

For the #SMARTGARDENER
Head Office/Service
11 Walters Drive, Osborne Park WA 6017
Tel: +61 8 9416 9999 Fax: +61 8 9416 9920
support@holmanindustries.com.au
www.holmanindustries.com.au
Copyright © 2023 Holman Industries

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals