Guangzhou DC 8V-24V Hall Switch Sensor Instructions

June 1, 2024
GUANGZHOU

Guangzhou DC 8V-24V Hall Switch Sensor

Guangzhou-DC-08V-24V-Hall-Switch-Sensor-product

Specifications

Size: 79mm43mm26mm
Net weight: 79.5g

Wiring Connection

Please connect the wiring as labeled on the product:

  1. The long black wire is connected to the negative pole of the power supply.
  2. The long red wire is connected to the positive pole of the power supply.
  3. The short black wire, short brown wire, and short blue wire are respectively connected to the corresponding wires of the same color of the Hall switch.

Installation

The Hall switch needs to be fixed firmly with a bracket. The installation distance between the Hall switch and the magnet must be within 10mm (the effective distance is subject to the detected magnet). The magnet has N/S sides, only one side is valid.

Precautions for Use

  • Avoid strong electromagnetic interference by using shielded wire or twisted-pair wire for measuring wire.
  • Avoid installing magnets on metallic iron materials as they will interfere with Hall’s detection.
  • The Hall switch and magnet need to be fixed firmly during detection to prevent data inaccuracies.
  • Use NPN normally open sensors for proper functioning.

FAQ

Common Problems and Solutions

Problem Cause Solution
The meter is not connected to the Hall switch. Install the Hall switch and

magnet in the correct way.
The meter is connected to the Hall switch, but the magnet is
not detected.| Magnet not installed, or distance too far, misalignment.| Detect within the product range, ensure correct
installation.
The actual speed is too low.| Issue with Hall switch.| Replace with a NPN normally open sensor.
The environment interferes with Hall switch detection.| Use environment interferes with Hall switch detection (e.g.,
inverter).| Use anti-jamming Hall sensor with shielded wire.
The actual speed is too high.| Environment interferes with Hall switch detection.| Use anti-jamming Hall sensor with shielded wire.
The Hall switch or magnet is not firmly fixed.| –| Ensure firm fixation during detection.

For more information, visit the manufacturer’s website: www.meimotor.com

Operating Instruction

TECHNICAL PARAMETERS

  • Input Voltage: DC 8V-24V, above 40mA
  • Display Mode: four-digit 0.56 LED
  • Measuring Range: 10-9999
  • Measuring accuracy: ±0.1%, reading ±1 word
  • Display refresh rate: >3 times/sec
  • Over-range Display: Below the detection range, “LLLL” is displayed; Above the detection range, “HHHH” is displayed

OPERATING INSTRUCTION

  • Please connect the wiring as the label on the product :
  1. The long black wire is connected to the negative pole of the power supply;
  2. The long red wire is connected to the positive pole of the power supply;
  3. The short black wire, short brown wire, and short blue wire are respectively connected to the corresponding wires of the same color of the Hall switch
  • The Hall switch needs to be fixed firmly with a bracket. The installation distance between the Hall switch and the magnet must be within 10mm (the effective distance is subject to the detected magnet)
  • The magnet has N/S sides, only one side is valid.

PRODUCT SPECIFICATIONS

  • Size: 79mm43mm26mm
  • Net weight: 79.5g

PRECAUTIONS FOR USE

  • Should avoid strong electromagnetic interference, it is better to use shielded wire or twisted-pair wire for measuring wire. Avoid the same tube or twisted wiring with other such as strong current wires or power wires to avoid unnecessary interference.
  • The matching Hall switch is an NPN normally open type with a diameter of 12mm. Customers can purchase other NPN normally open sensors instead
  • The Hall switch and magnet need to be fixed firmly during detection, otherwise the shaking of the Hall switch or magnet will cause the detection data to jump or be inaccurate. The installation distance between the Hall switch and the magnet must be within 10mm.
  • Magnets cannot be installed on metallic iron materials, as metallic materials will interfere with Hall’s detection. The magnet has N/S sides, only one side can be detected. When the Hall detects the magnet, the Hall lamp will flash.
    Common problems and solutions for product use
Problem Cause Solution
Displys “LLLL” The meter is not connected to the Hall switch.

Install the Hall switch and magnet in the correct way.

The meter is connected to the Hall switch, but the magnet is not detected.(maybe the magnet is not installed, or the distance between the Hall and the magnet is too far; Or the magnet and

the Hall switch are not aligned, etc.)

The actual speed is too low.| Detect within the product range
There is a problem with the Hall switch.| Replace a NPN normally open sensor
Use environment interferes with Hall switch detection. (such as inverter)| Use the anti-jamming Hall sensor with shielded wire, and connect the shielded wire with the negative wire of Hall signal.
Displays “HHHH”| The environment interferes with the Hall switch detection. (for example, Frequency converter)
The actual speed is too high.| Detect within the product range
Displays to jump or be inaccurate| The environment interferes with the Hall switch detection. (for example, Frequency converter)| Use the anti-jamming Hall sensor with shielded wire, and connect the shielded wire with the negative wire of Hall signal.

The Hall switch or magnet is not firmly fixed.

|