FRIGIDAIRE FFAD5034W1 Dehumidifier Energy Star Certified User Manual
- June 1, 2024
- Frigidaire
Table of Contents
- FRIGIDAIRE FFAD5034W1 Dehumidifier Energy Star Certified
- INTRODUCTION
- IMPORTANT SAFETY INSTRUCTIONS
- LOCATION & HOW IT WORKS
- DEHUMIDIFIER FEATURES & OPERATING INSTRUCTIONS
- OPERATING INSTRUCTIONS
- OPERATING INSTRUCTIONS & CARE AND CLEANING
- STORAGE & NORMAL SOUNDS
- BEFORE YOU CALL
- MAJOR APPLIANCE LIMITED WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
FRIGIDAIRE FFAD5034W1 Dehumidifier Energy Star Certified
INTRODUCTION
Welcome to our family
Thank you for bringing Frigidaire® into your home! We see your purchase as the beginning of a long relationship together. This manual is your resource for the use and care of your product. Please read it before using your appliance. Keep it handy for quick reference. If something doesn’t seem right, the troubleshooting section will help you with common issues. FAQs, helpful tips and videos, cleaning products, and kitchen and home accessories are available at www.frigidaire.com. We are here for you! Visit our website, chat with an agent, or call us if you need help. We may be able to help you avoid a service visit. If you do need service, we can get that started for you. Let’s make it official! Be sure to register your product. Keep your product info here so it’s easy to find.
- Model Number
- Serial Number
- Purchase Date
IMPORTANT SAFETY INSTRUCTIONS
WARNING
For Your Safety
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Read product labels for flammability and other warnings.
- Discard water from a bucket. Water is not potable and cannot be used for drinking.
WARNING
Electrical Information
- For your safety and protection, this dehumidifier is equipped with a three-prong grounding plug on the power cord. Do not, under any circumstances, cut or remove the round ground prong from the plug.
- Your dehumidifier must be plugged directly into a properly grounded and polarized three-prong receptacle. lf the wall receptacle you intend to use will not accept a three-prong plug, or if you are not sure the outlet is adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper outlet according to the National Electrical Code and applicable local codes and ordinances. Do not use an extension cord or an adapter plug.
- Never unplug the dehumidifier by pulling on the power cord. Always grip the plug firmly and pull straight out from the receptacle.
- Do not pinch, bend, or knot the power cord.
WARNING
Child Safety Precautions
- Destroy the carton, plastic bags, and any packing materials immediately after the dehumidifier is unpacked. Children should never use these items for play.
- Do not leave children unattended in an area where the appliance is operating. Do not allow them to sit or stand on the appliance.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
SAFETY PRECAUTIONS
DANGER! Avoid Serious Injury or Death
- This dehumidifier contains no user-serviceable parts. Always call an authorized Electrolux servicer for repairs.
- Do not insert or place fingers or objects into the air discharge area or back grille of the unit.
- Do not start or stop the dehumidifier by unplugging the power cord or turning off the power at the electrical box.
- Do not cut or damage the power cord. Do not pull on the power cord.
- If the power cord is damaged, it should only be replaced by an authorized Electrolux servicer.
- In the event of a malfunction (sparks, burning smell, etc.), immediately stop the operation, disconnect the power cord, and call an authorized Electrolux servicer.
- Do not operate the dehumidifier with wet hands. Do not drink any water from the dehumidifier.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons to avoid a hazard.
- The appliance shall be installed according to national wiring regulations.
CAUTION! Avoid Injury or damage to the unit or other property
- Do not direct airflow at fireplaces or other heat-related sources as this could cause flare-ups.
- Do not climb on or place objects on the unit. Do not hang objects off the unit.
- Do not place containers with liquids on the unit.
- Turn off the dehumidifier at the power source when it will not be used for an extended period.
- Operate the unit with an air filter in place.
- Do not block or cover the intake grille, discharge area, and outlet ports.
- Ensure that any electrical/electronic equipment is one yard away from the unit.
- Do not use or store flammable gases near the unit.
WARNING
Avoid fire hazard or electric shock. Do not use an extension cord or an adaptor plug. Do not remove any prong from the power cord.
WARNING
FOR FLAMMABLE REFRIGERANT
- Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
- DO NOT modify the length of the power cord or use an extension cord to power the unit.
- DO NOT share a single outlet with other electrical appliances. Improper power supply can cause fire or electrical shock.
- Please follow the instructions carefully to handle, install, clear, and service the air conditioner to avoid any damage or hazard.
- Flammable Refrigerant R32 is used within the air conditioner. When maintaining or disposing of the air conditioner, the refrigerant (R32) shall be recovered properly, and shall not discharge to air directly.
- Compliance with national gas regulations shall be observed.
- Keep ventilation openings clear of obstruction.
- The appliance shall be stored to prevent mechanical damage from occurring.
- A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
- Any person who is involved with working on or breaking into a refrigerant circuit should hold a currently valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely by an industry-recognized assessment specification.
Examples of such working procedures are:
- breaking into the refrigerating circuit;
- opening of sealed components;
- opening of ventilated enclosures.
- No any open fire or device like a switch which may generate spark/arcing shall be around the air conditioner to avoid causing ignition of the flammable refrigerant used. Please follow the instructions carefully to store or maintain the air conditioner to prevent mechanical damage from occurring.
- Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
- The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance) and ignition sources or (for example: an operating electric heater) close to the appliance.
- Do not pierce or burn.
- Be aware that the refrigerants may not contain an odor.
-
Transport of equipment containing flammable refrigerants. See transport regulations.
-
Marking of equipment using signs See local regulations.
-
Disposal of equipment using flammable refrigerants See national regulations.
-
Storage of equipment/appliances The storage of equipment should be under the manufacturer’s instructions.
-
Storage of packed (unsold) equipment Storage package protection should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge. The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations.
-
Information on servicing
- Checks to the area Before beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with before conducting work on the system.
- Work procedure Work shall be undertaken under a controlled procedure to minimize the risk of flammable gas or vapvaporing present while the work is being performed.
- General work area All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.
- Checking for the presence of refrigerant The area shall be checked with an appropriate refrigerating detector before and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. non-sparking, adequately sealed,d or intrinsically safe.
- Presence of fire extinguisher If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.
- No ignition sources No person carrying out work about a refrigerating system that involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repair, removal, and disposal, during which flammable refrigerant can be released into the surrounding space. Before work taking the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. No Smoking signs shall be displayed.
- Ventilated area Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.
- Checks to the refrigerating equipment Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance. The following checks shall be applied to installations using flammable refrigerants: The actual refrigerant charge is by the room size within which the refrigerant-containing parts are installed; The ventilation machinery and outlets are operating adequately and are not obstructed; If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant; Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected; Refrigerating pipes or components are installed in a position where they are unlikely to be exposed to any substance that may corrode refrigerant-containing components unless the components are constructed of materials that are inherently resistant to being corroded or are suitably protected against being so corroded.
- Checks to electrical devices Repair and maintenance of electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised. Initial safety checks shall include: That capacitors are discharged: this shall be done safely to avoid the possibility of sparking; That no live electrical components and wiring are exposed while charging, recovering, or purging the system; That there is continuity of earth bonding.
-
Repairs to sealed components
- During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon before any removal of sealed covers, etc. If it is necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
- Particular attention shall be paid to the following to ensure that by working on electrical components, the casing is not altered in such a way that the level of protection is affected. This shall include damage to cables, excessive number of connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc. Ensure that the apparatus is mounted securely. Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of flammable atmospheres. Replacement parts shall betray the manufacturer’s specifications.
NOTE: The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment. Intrinsically safe components do not have to be isolated before working on them.
-
Repair to intrinsically safe components
Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use. Intrinsically safe components are the only types that can be worked on while living in the presence of a flammable atmosphere. The test apparatus shall be at the correct rating. Replace components only with parts specified by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere from a leak.
Cabling
Check that cabling will not be subject to wear, corrosion, excessive pressure,
vibration, sharp edges, or any other adverse environmental effects. The check
shall also take into account the effects of aging or continual vibration from
sources such as compressors or fans.
Detection of flammable refrigerants
Under no circumstances shall potential sources of ignition be used in the
search for or detection of refrigerant leaks. A halide torch (or any other
detector using a naked flame) shall not be used. The following leak-detection
methods are deemed acceptable for systems containing flammable refrigerants.
Electronic leak detectors shall be used to detect flammable refrigerants, but
the sensitivity may not be adequate or may need re-calibration. (Detection
equipment shall be calibrated in a refrigerant-free area). Ensure that the
detector is not a potential source of ignition and is suitable for the
refrigerant used. Leak detection equipment shall be set at a percentage of the
LFL of the refrigerant and shall be calibrated to the refrigerant employed and
the appropriate percentage of gas (25 % maximum) is confirmed. Leak detection
fluids are suitable for use with most refrigerants but the use of detergents
containing chlorine shall be avoided as the chlorine may react with the
refrigerant and corrode the copper pipe-work. If a leak is suspected, all
naked flames shall be removed/extinguished. If a leakage of refrigerant is
found that requires brazing, all of the refrigerants shall be recovered from
the system, or isolated (using shut-off valves) in a part of the system remote
from the leak. Removal of refrigerant shall be according to Removal and
evacuation.
Removal and evacuation
When breaking into the refrigerant circuit to make repairs – or for any
other purpose–conventional procedures shall be used. However, for flammable
refrigerants best practice must be followed since flammability is a
consideration. The following procedure shall be adhered to:
- safely remove refrigerant following local and national regulations;
- purge the circuit with inert gas;
- evacuate (optional for A2L);
- purge with inert gas (optional for A2L);
- open the circuit by cutting or brazing. The refrigerant charge shall be recovered into the correct recovery cylinders if venting is not allowed by local and national codes. For appliances containing flammable refrigerants, the system shall be purged with oxygen-free nitrogen to render the appliance safe for flammable refrigerants. This process might need to be repeated several times. Compressed air or oxygen shall not be used for purging refrigerant systems. For appliances containing flammable refrigerants, refrigerant purging shall be achieved by breaking the vacuum in the system with oxygen-free nitrogen and continuing to fill until the working pressure is achieved, then venting to the atmosphere, and finally pulling down to a vacuum (optional for A2L). This process shall be repeated until no refrigerant is within the system (optional for A2L). When the final oxygen-free nitrogen charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. Ensure that the outlet for the vacuum pump is not close to any potential ignition sources and that ventilation is available.
Charging procedures
In addition to conventional charging procedures, the following requirements
shall be followed. Ensure that contamination of different refrigerants does
not occur when using charging equipment. Hoses or lines shall be as short as
possible to minimize the amount of refrigerant contained in them. Cylinders
shall be kept in an appropriate position according to the instructions. Ensure
that the refrigeration system is earthed before charging the system with
refrigerant. Label the system when charging is complete (if not already).
Extreme care shall be taken not to overfill the refrigeration system. Before
recharging the system it shall be pressure tested with OFN. The system shall
be leak tested on completion of charging but before commissioning. A follow-up
leak test shall be carried out before leaving the site.
Decommissioning
Before carrying out this procedure, the technician must be completely familiar
with the equipment and all its details. It is recommended good practice that
all refrigerants are recovered safely. Before the task is carried out, an oil
and refrigerant sample shall be taken in case analysis is required before the
re-use of reclaimed refrigerant. Electrical power must be available before the
task is commenced.
- Become familiar with the equipment and its operation.
- Isolate system electrically.
- Before attempting the procedure ensure that: Mechanical handling equipment is available, if required, for handling refrigerant cylinders; All personal protective equipment is available and being used correctly; The recovery process is supervised at all times by a competent person; Recovery equipment and cylinders conform to the appropriate standards.
- Pump down the refrigerant system, if possible.
- If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system.
- Make sure that the cylinder is situated on the scales before recovery takes place.
- Start the recovery machine and operate by instructions.
- Do not overfill cylinders. (No more than 80% volume liquid charge).
- Do not exceed the maximum working pressure of the cylinder, even temporarily.
- When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equipment are removed from sthe site promptly and all isolation valves on the equipment are closed off.
- Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked.
Labeling
Equipment shall be labeled stating that it has been de-commissioned and
emptied of refrigerant. The label shall be dated and signed. Ensure that there
are labels on the equipment stating the equipment contains flammable
refrigerant.
Recovery
When removing refrigerant from a system, either for servicing or
decommissioning, it is recommended good practice that all refrigerants are
removed safely. When transferring refrigerant into cylinders, ensure that only
appropriate refrigerant recovery cylinders are employed. Ensure that the
correct number of cylinders for holding the total system charge is available.
All cylinders to be used are designated for the recovered refrigerant and
labeled for that refrigerant (i.e. special cylinders for the recovery of
refrigerant). Cylinders shall be complete with pressure relief valves and
associated shut-off valves in good working order. Empty recovery cylinders are
evacuated and, if possible, cooled before recovery occurs.
The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants. In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained, and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release. Consult the manufacturer if in doubt. The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant Waste Transfer Note arranged. Do not mix refrigerants in recovery units especially not in cylinders. If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out before returning the compressor to the suppliers. Only electric heating of the compressor body shall be employed to accelerate this process. When oil is drained from a system, it shall be carried out safely. Non-duct connected appliances containing A2L refrigerants with the supply and return air openings in the conditioned space may have the body of the appliance installed in open areas such as false ceilings not being used as return air plenums, as long as the conditioned air does not directly communicate with the air of the false ceiling.
Wiring Diagram
LOCATION & HOW IT WORKS
Location Selecting a Location
IMPORTANT:
- Dehumidifier must be operated in an enclosed area to be most effective. Close all doors, windows, and other outside openings in the room. The effectiveness of the dehumidifier depends on the rate at which new moisture-laden air enters the room.
- Place dehumidifier in a location that does not restrict the airflow of the air intake and air outlet.
- A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed storage area, such as a closet unless there is adequate circulation of air in and out of the area. It may be necessary to install a second dehumidifier in the enclosed area for satisfactory drying.
- The dehumidifier must be installed on a level floor that will support it with a full bucket of water.
- There should be a minimum of 12 inches of clearance around the dehumidifier. The unit will produce heat while in operation and should not be operated in an enclosed small space like a closet.
How It Works
When the unit is started, the fan begins to pull moisture-laden air across the
dehumidifying coils. The coils condense or draw moisture from the air, and air
flows through the air outlet louvers into the room as dry, warm air. Moisture
removed from the air is collected in a bucket on the front of the dehumidifier.
The unit is designed to operate between 41°F (5°C), and 89°F (32°C) and
between 30%(RH) and 80%(RH). The unit will not work properly if the
temperature is out of this temperature range, or the performance of the unit
will fall greatly. The “Compressor” circuit has an automatic 3-minute time
delayed start if the unit is turned off and on quickly. This prevents
overheating of the compressor and possible circuit breaker tripping. Make sure
the tank is fitted correctly otherwise unit will not turn on.
DEHUMIDIFIER FEATURES & OPERATING INSTRUCTIONS
Dehumidifier Features
ELECTRONIC CONTROL
Before you begin, thoroughly familiarize yourself with the control panel and
all its functions (as shown below).
- A Check Filter Reset Button
- B Bucket Full Indicator
- C Displays Humidity
- D Turns Unit On Or OFF
- E Sets Fan Speed
- F Adjusts Humidity
- G Sets Timer
Operating Instructions
Allow the unit to reach room temperature before operating. To begin operating the dehumidifier, follow these steps:
NOTE
The unit must be upright for one hour before operating.
-
Plug the power cord into a properly grounded 115-volt AC outlet.
NOTE
If the “BUCKET FULL” light is on, remove the bucket and re-install it to reset the float switch. -
To turn the unit on, press the ON/OFF button. The unit will run in the factory setting of CONTINUOUS and high fan speed. In the CONTINUOUS mode, the unit will only display CO and not the room humidity. It is recommended you leave the unit running in the CONTINUOUS setting for the first three or four days until the sweating and dampness odors have stopped.
OPERATING INSTRUCTIONS
- After a few days when the Relative Humidity has declined, press the HUMIDITY (DOWN ) or (UP ) buttons to choose a value between 35% to 85%, so the room is kept at a comfortable humidity. Pressing the ( DOWN) or (UP) buttons will change the humidity selection in 5% increments. 5 seconds after you have set the desired humidity, the readout will display the actual room humidity. If at any time you want to return to the CONTINUOUS Mode, pressing the HUMIDITY (DOWN) button will lower the Relative Humidity through 5%decrements until the display reads CO.
- You can also use the FAN SPEED button to change the fan speed to Hi, Med, or Lo. The indicator light will show the setting you have selected. A higher fan speed will result in quicker moisture removal.
- The Filter reset light will illuminate after 250 hours of operation. At this time refer to the care and cleaning section to remove and clean the filter. Once the filter has been cleaned and replaced, simply press the Filter reset button to extinguish the light.
- The TIMER function enables you to either Delay Start or Delay Stop the unit in the choice from 0.5 hours to 24 hours. If the unit is running, then selecting Timer will turn the unit off in the hours that will be set (Delay Stop). If the unit is off, then selecting Timer will turn the unit on in the hours that will be set (Delay Start). TIMER setting: First press the TIMER button, then adjust the timer setting, by tapping or holding the (DOWN) or (UP) button to change the delay timer at 0.5 hour increments, up to 10 hours, then by 1 hour increments up to 24 hours. The control will count down the time remaining (8h, 7.5h, 7h, etc.) until the unit either starts or stops. For the Delay Start, the fan speed and humidity maintained will be the same as the previous setting. After the TIMER setting finishes, pressing the TIMER button again at any time will stop the TIMER function. The Delay Start/Stop Feature will work until the unit either starts or stops. Once that happens the above steps have to be repeated. NOTE
- Before entering the TIMER setting, make sure power is being supplied to the unit.
- Before entering the TIMER setting, make sure pressing the HUMIDITY ( DOWN) or (UP) button sets one desired room humidity first.
- To shut the unit down, press the ON/OFF button.
Note: After a power outage, the unit will memorize the last setting and return the unit to the same setting once power is restored.
Fault Codes
- If the display reads “AS” or “ES”, a sensor has failed. Contact your Authorized Frigidaire® Service Center.
- If the display reads “EC”, check the following operating conditions. Outlet voltage should be 115V±10% and the surrounding temperature should be within the range of 41 °F to 89 °F. Unplug the unit and plug it in again under normal operating conditions. If the “EC” code persists, contact your Authorized Frigidaire® Service Center.
- If the display reads “E4”, the communication between the display PCB and the main control PCB is faulty. Contact your Authorized Frigidaire® Service Center.
Removing Collected Water
- Emptying the Bucket:
- When the bucket is full, the unit will shut down and the BUCKET FULL indicator will illuminate.
- Do not move the unit at this time otherwise, water may spill on the floor.
- Press the sides of the bucket gently to unclip the bucket from the unit.
- Remove the bucket as shown in the photographs below and empty the bucket.
WARNING
Discard water from a bucket. Water is not potable and cannot be used for
drinking.
- Replace the empty bucket into the unit and once seated correctly, the unit will start up again.
- You should hear a click when the bucket is in the correct position.
If the bucket full light does not extinguish, check that the float is correctly snapped in place.
Continuous Drainage:
- For continuous drainage operation, you will need a garden hose and a drain nearby to discharge the water.
- Unscrew the drain cap on the back side of the unit. (fig.1)
- Insert the female threaded end of the hose onto the drain connector of the unit. (fig.2)
- Screw the garden hose onto the threaded portion of the drain connector. (fig.3)
OPERATING INSTRUCTIONS & CARE AND CLEANING
- Make sure the hose is secure so there are no leaks.
- Direct the hose toward the drain, making sure that there are no kinks that will stop the water flowing.
- Place the end of the hose into the drain. (fig.4)
- Select the desired humidity setting and fan speed on the unit for continuous draining to start.
NOTE
- Check the seal between the hose and the drain connector. If there is a small leak then replace the hose gasket and re-tighten the hose.
- It is recommended that a Dehumidifier Drain Hose – 1/2″ (12.7 mm) or larger be used. Make sure there are no kinks or elevations in the hose.
- When a hose is not attached to the drain connector, please ensure the drain cap is screwed securely to the connector to prevent leakages.
Care and Cleaning
-
Filter
Clean the filter every two weeks based on normal operating conditions.
To remove the filter:- Open the back grille.
- Detach the filter from the back of the grille by pressing the tabs as shown below.
STORAGE & NORMAL SOUNDS
- Wash the filter with clean water then dry.
- Re-install the filter.
Cabinet
- Dust cabinet with an oil-free cloth, or using a damp cloth.
- Vacuum grill using a brush attachment.
Water Bucket
Clean the Water Bucket every two weeks based on normal operating conditions.
- Clean the bucket with warm water and detergent.
Storage
When a unit is not in use, unplug and use the cord wrap shown for your model
type.
Normal Sounds
- Dripping Sound The sound of dripping water may be heard during the dehumidification cycle.
- Sound of Rushing Air At the top of the unit, you may hear the sound of rushing air being moved by the fan.
- Gurgle/Hiss “Gurgling or hissing” noise may be heard due to refrigerant passing through the evaporator during normal operation.
- High-pitched Chatter Today’s high-efficiency compressors may have a high-pitched chatter during the dehumidification cycle.
BEFORE YOU CALL
Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of defective workmanship or materials in this appliance.
OCCURRENCE | SOLUTION |
---|
The dehumidifier does not operate.
| • Wall plug disconnected. Push plug firmly into a wall outlet.
• House fuse blown or circuit breaker tripped. Replace the fuse with a time delay
type or reset the circuit breaker.
• The dryness level you selected has been reached. Dehumidifier automatically shuts off when a selected amount of moisture has been removed from the air. If you want to remove more moisture, Select ‘CONTINUOUS’ by using the humidity button or knob. After the dehumidifier starts, reset the control to the desired setting.
• Bucket not installed properly. See “Removing Collected Water“.
• Water in the bucket has reached its preset level. Dehumidifier automatically
turns off when this occurs. Empty the bucket and return the bucket to the position.
• Dehumidifier is not turned on. Turn the unit on.
• “BUCKET FULL“ light is on. Remove the bucket, empty water, and re-install
correctly.
The dehumidifier runs too much.
| • Windows or doors near the dehumidifier are open outdoors. Close all windows
or doors to outside.
• The area to be dehumidified is too large. Check with your dealer to see if capacity
is adequate.
• Air movement through the dehumidifier is blocked. The grill may be dirty. Use the brush attachment of a vacuum cleaner to clean the grill. See “Care and Cleaning”. The dehumidifier must be placed in a space that does not restrict air flow into the rear coil or out of the front grill.
• Dehumidifier has been installed or restarted recently. The higher the
moisture in the room, the longer the dehumidifier will operate.
• Dehumidifier is in the CONTINUOUS mode and will remain in this mode,
use the humidity button or knob to set a RH% higher level.
The dehumidifier is operating but the room is not dry enough.
| • Humidity setting is too high. Press the HUMIDITY button or rotate the knob to a
lower setting or choose CONTINUOUS for maximum dryness.
• Dehumidifier has been installed or restarted recently. The higher the moisture
in the room air, the longer it takes for the room air to become dry.
• Dehumidifier does not have sufficient clearance to operate. Air flow to the air
outlet is blocked. See “Selecting a Location”.
• Room temperature is too low. The unit will not operate satisfactorily if the room
temperature is below 41°F(5°C). See “Operating Conditions”.
• Refer to causes under DEHUMlDIFIER RUNS TOO MUCH.
Frost appears on coils behind the filter
| • Dehumidifier has been turned on recently. This is normal due to refrigerant
rushing through the coil. Frost will usually disappear within 60 minutes.
• Room Temperature is too low. All models will operate satisfactorily at
temperatures greater than 41°F (5°C).
Fan noise.| • Air is moving through the dehumidifier. This is a normal sound.
If These Solutions Fail, Call 1-800-944-9044(US)/1-800-265-8352(Canada) For Frigidaire® Service.
MAJOR APPLIANCE LIMITED WARRANTY
Your appliance is covered by a limited one-year warranty for functional repairs only. For one year from your original date of purchase, Electrolux will pay all costs for repairing or replacing any parts of this appliance that prove to be defective in materials or workmanship when such appliance is installed, used, and maintained by the provided instructions. After one year from your original date of purchase, the consumer will be responsible for diagnostic, labor, and parts costs as well as any removal, transportation, and reinstallation expenses that are incurred during service on components.
Exclusions This warranty does not cover the following:
- Products with original serial numbers that have been removed, altered, or cannot be readily determined.
- Product that has been transferred from its original owner to another party or removed outside the USA or Canada.
- Rust on the interior or exterior of the unit.
- Products purchased “as-is” are not covered by this warranty.
- Food loss due to any refrigerator or freezer failures.
- Products used in a commercial setting.
- Service calls that do not involve malfunction or defects in materials or workmanship, or for appliances not in ordinary household use or used other than by the provided instructions.
- Service calls to correct the installation of your appliance or to instruct you how to use your appliance.
- Expenses for making the appliance accessible for servicing, such as removal of trim, cupboards, shelves, etc., which are not a part of the appliance when it is shipped from the factory.
- Service calls to repair or replace appliance light bulbs, air filters, water filters, other consumables, or knobs, handles, or other cosmetic parts.
- Surcharges include, but nare ot limited to, any after-hour, weekend, or holiday service calls, tolls, ferry trip charges, or mileage eexpensesfor service calls to remote areas, including the state of Alaska.
- Damages to the finish of appliance or home incurred during installation, including but not limited to floors, cabinets, walls, etc.
- Damages caused by: services performed by unauthorized service companies; use of parts other than genuine Electrolux parts or parts obtained from persons other than authorized service companies; or external causes such as abuse, misuse, inadequate power supply, accidents, fires, or acts of God.
DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES
CUSTOMER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE
PRODUCT REPAIR OR REPLACEMENT AS PROVIDED HEREIN. CLAIMS BASED ON IMPLIED
WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY
LAW, BUT NOT LESS THAN ONE YEAR. ELECTROLUX SHALL NOT BE LIABLE FOR
CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL
EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN LIMITED WARRANTY OR ANY
IMPLIED WARRANTY. SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR
LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, OR LIMITATIONS ON THE
DURATION OF IMPLIED WARRANTIES, SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT
APPLY TO YOU. THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY
ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE.
If You Need Service
Keep your receipt, delivery slip, or some other appropriate payment record to establish the warranty period should service be required. If service is performed, it is in your best interest to obtain and keep all receipts. Service under this warranty must be obtained by contacting Electrolux at the addresses or phone numbers below. This limited warranty only applies in the USA and Canada. In the USA, your appliance is warranted by Electrolux Major Appliances North America, a division of Electrolux Home Products, Inc. In Canada, your appliance is warranted by Electrolux Canada Corp. Electrolux authorizes no person to change or add to any obligations under this warranty. Obligations for service and parts under this warranty must be performed by Electrolux or an authorized service company. Product features or specifications as described or illustrated are subject to change without notice.
USA 1.800.944.9044
Electrolux Major Appliances 10200 David Taylor Drive Charlotte, NC 28262
Canada 1.800.265.8352
Electrolux Canada Corp. 5855 Terry Fox Way Mississauga, Ontario, Canada L5V
3E4
Our home is your home. Visit us if you need help with any of these things:
(See your registration card for more information.)
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>