bsaunas Halden M Log Sauna Instruction Manual
- June 1, 2024
- bsaunas
Table of Contents
- BASE PLAN
- FLOOR FRAMING 45 x 95
- FASTENING WALL LOGS
- FLOOR BOARDS
- ROOF BOARDS
- FASTENING DOORS/WINDOWS
- DOOR WINDOW MOULDINGS
- CEILING INSULATION IN SAUNA ROOM
- FASTENING BENCH MODULES
- CROSS-SECTION OF SAUNA ROOM AND HEIGHT OF BENCH MODULES
- FASTENING GRID WALLS AND ADJUSTING POSTS
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
bsaunas Halden M Log Sauna Instruction Manual
HOUSE: HALDEN M 40
POS. | DESCRIPTION | NOTE | PCS. | PROFILE | LENGTH |
---|---|---|---|---|---|
AR5 | IMPREGNATED FLOOR FRAMING | 1 | 45×95 | 3915 | |
AR4 | IMPREGNATED FLOOR FRAMING | CUTOUT | 1 | 45×95 | 3915 |
AR3 | IMPREGNATED FLOOR FRAMING | 13 | 45×95 | 1980 | |
AR1 | IMPREGNATED FLOOR FRAMING | CUTOUT | 1 | 45×95 | 1980 |
AR2 | IMPREGNATED FLOOR FRAMING | 1 | 45×70 | 1980 | |
PL-1 | FLOOR BOARD | SAUNA ROOM | 18+2 | 24×112 | 1965 |
PL-2 | FLOOR BOARD | FRONT ROOM | 18+2 | 24×112 | 996 |
KL-1 | ROOF BOARD | 40+4 | 24×112 | 2668 | |
SL-1 | CEILING BOARD | SAUNA ROOM | 18+2 | 14×111 | 2013 |
TL-1 | IMPREGNATED TERRACE BOARD | 17+2 | 28×120 | 800 | |
TL-2 | IMPREGNATED TERRACE BOARD | 1 | 28×120 | 2070 | |
PP-1 | FLOOR/CEILING/ROOF MOULDING | 18+2 | 15×55 | 2100 | |
DL-1 | SPACER | 4 | 15×55 | 1996 | |
R-1 | BATTEN | BEVELLED | 2 | 45×45 | 1996 |
RLT-1 | ROOF EDGE SUPPORT | 2 | 45×45 | 4446 | |
RL-1 | ROOF EDGE BOARD | 2 | 18×95 | 2800 | |
RL-2 | ROOF EDGE BOARD | 2+1 | 18×95 | 4500 | |
APL55-1 | **** MOULDINGS FOR 845+845×1792 WINDOW | **** 1 SET | 2 | ||
15×55 | 1752 | ||||
APL95-1 | 2 | 18×95 | 1650 | ||
APL95-2 | 2 | 18×95 | 1900 | ||
APL95-3 | 4 | 18×95 | 1877 | ||
APL95-4 | **** MOULDINGS FOR 690×1792 WINDOW | **** 1 SET | 2 | 18×95 | 650 |
APL95-5 | 2 | 18×95 | 900 | ||
APL95-6 | 4 | 18×95 | 1877 | ||
UPL95-1 | **** MOULDINGS FOR 690×1860 DOOR | **** 2 SETS | 2 | 18×95 | 920 |
UPL95-2 | 4 | 18×95 | 1890 | ||
UPL-1 | EXTRA MOULDING | 2 | 18×95 | 2400 | |
DESCRIPTION | NOTE | PCS. | |||
--- | --- | --- | --- | ||
**** DOORS/WINDOWS | EXTERIOR DOOR WITH WOODEN FRAME 88x690x1860 | 1 | |||
GLASS DOOR 88x690x1860 | 1 | ||||
WINDOW 45x845x1792 | 2 | ||||
WINDOW 45x690x1792 | 1 | ||||
DOOR HANDLE SET FOR EXTERIOR DOOR | 1 | ||||
DOOR KNOB SET FOR GLASS DOOR | 1 | ||||
**** COMPONENTS | BENCH MODULE 600×1992 | 1 | |||
BENCH MODULE 400×1992 | 1 | ||||
BENCH MODULE 500×992 | 1 |
BENCH SUPPORTS SET 45×45 (560-3PCS, 500-1PC, 465-2PCS, 452-2PCS,
375-2PCS)| | 1
ADDITIONAL VERTICAL BENCH SUPPORT 45x45x1000| ADJUSTABLE| 1
OUTDOOR BENCH 563×750| | 1
|
GRID WALL 650×1711| | 1
3MM SLOPE BOARD| 1996MM| 1
6MM SLOPE BOARD| 1996MM| 1
9MM SLOPE BOARD| 1996MM| 1
12MM SLOPE BOARD| 1996MM| 1
INSULATION SHEET 30x600x1200| | 6
ALUMINUM TAPE| | 20M
WOODEN VENTILATION LOUVER D100| | 2
METAL VENTILATION GRID D100| | 2
DRAINAGE 2000+| OPENS RIGHT| 1
FASTENERS| 3.5×50 SCREW FOR FLOOR BOARDS| 200
3×40 STAINLESS SCREW FOR DOOR/WINDOW MOULDINGS| 200
4.2×55 STAINLESS SCREW FOR TERRACE AND ROOF EDGE BOARDS| 200
5×40 SCREW FOR ANGLE BRACKETS| 100
4.5×60 SCREW FOR ROOF EDGE SUPPORT| 50
4.5×70 SCREW FOR BENCH MODULES, BATTENS, GRID WALL AND DOOR FRAME| 150
5×90 SCREW FOR FLOOR FRAMING AND CONNECTING WALL LOGS WITH FLOOR FRAMING|
100
6×120 SCREW FOR WALL LOG INTERSECTIONS| 250
6×180 SCREW FOR PURLINS, CONNECTING WALL LOGS WITH FLOOR FRAMING AND WALL
LOGS| **** 40
75MM NAIL FOR ROOF BOARDS| 400
40MM LOST HEAD NAIL FOR CEILING BOARDS| 300
ADJUSTABLE POST SUPPORT 60×60| 1
SLIDING BRACKET 35x35x130 FOR GRID WALL| 2
WASHER M5 FOR SLIDING BRACKET| 2
ANGLE BRACKET 40x40x40 FOR WINDOWS| 12
BASE PLAN
FLOOR FRAMING 45 x 95
NB! Check diagonals, remember that A=B=4429
Use two 5×90 screws to fasten joist ends with crossing joists. Fix with parallel joists, when there is no crossing joists. AR3
FASTENING WALL LOGS
Fasten first row to floor framing. Use 5×90 screws for half logs (fix those
first) and 6×180 screws for full logs. It is recommended to predrill holes. If
necessary use rubber hammer and hit block to secure logs tightly on top of
each other.
Use 6×120 screws in each intersection. Try to alternate placement of drill holes so screws dont end up on top of each other. It is recommended to predrill the holes.
Framing should be 5mm inside from outer wall.
Pos| | Pcs| Profile
Imm)| Length
(mm)
---|---|---|---|---
001| | 1| 40×136| 4446
002| | 2| 40×136| 4446
003| | 2| 40×136| 4246
| | 16| 40×136| 3320
005| | 1| 40×136| 3320
006| ****| 14+1| 40×136| 2280
007| | 3| 40×136| 2280
008| | 3| 40×136| 2280
009| | 3| 40×68| 2280
010| | 3| 40×136| 1670
011| | 28| 40×136| 1212
012| | 3| 40×87| 650
013| | 28| 40×136| 368
014| | 13| 40×136| 330
015| | 26| 40×136| 285
P1| HIT BLOCK 40MM| 1| 70×70| 1912
PR1| | 2| 45×145| 4446
WALL (A)
WALL (B)
WALL (C)
WALL (1)
WALL (2)
FLOOR BOARDS
Add slope boards and drainage details before fixing floor boards.
When placing drainage, fix closed end temporarily 5mm higher than opened end to guarantee slope towards outer wall for water. After placing floor boards fix it permanently with floor mouldings.
Fasten floor boards with screws from the tongue side of the board. First board
should be placed -5mm from wall and when cutting last board make sure there is
5mm gap as well. Leave 2mm gap between floor board (cross cut sides) and
walls. Lastly fix mouldings in place.
Fasten terrace boards with two screws in each connection.
ROOF BOARDS
-
Fix purlins with 6×180 screws (predrill holes).
-
Fix roof boards with 75mm nails (2pcs for each connection).
-
Fasten roof edge support and board. Use 4,5×60 screws (one for every other board ending) to fix edge support. For edge boards use 4,2×55 srews.
-
Cut gable edge boards to length and fix with 4,2×55 screws.
FASTENING DOORS/WINDOWS
-
Fasten 40x40x40 angle brackets to window jambs (3pcs for each side) with two 5×40 screws. Make sure that brackets are 3mm inside from outer surface of the jamb, so there will be enough room for screw heads when mounting windows to walls and fixing mouldings.
-
Lift window in place and fasten angle brackets to wall with 5×40 screws (2pcs for each bracket).
-
Fasten mouldings with 3×40 screws. Mouldings should cover about 20mm of frame.
-
Lift door in place and fix it to wall by screwing 4,5×70 screws through wall to frame.
-
Fasten mouldings with 3×40 screws. Mouldings coverage is about 20mm on upper moulding and 10mm on sides. There are no mouldings on the side of the frame.
DOOR WINDOW MOULDINGS
CEILING INSULATION IN SAUNA ROOM
-
Fasten battens (R-1) to side walls so that they are in line with purlins. Use 4,5×70 screws.
-
Place insulation sheets under purlins (use few left over screws from previous steps to hold sheets in place). Tape screw holes in sheets, connection seams and perimeter with aluminum tape.
-
Fasten spacers under battens/purlins with 4,5×70 screws to secure insulation sheets properly in place.
-
Fix ceiling boards under spacers with lost head nails. (two nails for each connetion). Finally fasten mouldings around perimeter using lost head nails.
FASTENING BENCH MODULES
This is an overall manual for bench modules. You can skip some of the steps depending on the set (for example if there is no bench skirt). Precise heights for bench supports and benches can be found on the next page.
-
Fasten bench supports with screws to wall. Use glue between wall and support for stronger connection.
-
Lift modules in place and fix them to the supports on the walls. Do not install upper module in case there is bench skirt in set
-
Lift bench skirt in place, attach it to wall from sides and to lower bench in middle. There should be 8mm gap between lower bench and bench skirt.
-
Place upper module and fix it in place as described in step two.
CROSS-SECTION OF SAUNA ROOM AND HEIGHT OF BENCH MODULES
Use 4,5×70 screws to fasten bench supports to walls and to fix benches to
already fixed supports. Lower module position is approximate (can be placed
according to your own preferance). Outdoor bench support must be fixed at the
same height as is lenght of vertical supports.
FASTENING GRID WALLS AND ADJUSTING POSTS
Use sliding brackets to fix grid wall to house. Fasten slider to the wall logs. Leave the side with a slot on the side of grid wall, put MS washer between screw and slider. Do not fix the screw too tight to enable the house to move different from grid wall.
After house is built it is necessary to adjust post support. Otherwise house
will settle, but not the parts that are supported by post and there will be
gaps between wall logs. Loosen nut under post and wait a little bit so house
can settle. Then turn nut back against plate.
Adjusting should be done once a month after house has been built, then once
every three months after half a year has passed and after first year it is
enough to adjust post supports once or twice a year.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>