MEAN WELL LPV-150 Series 150W Single Output Switching Power Supply Owner’s Manual

June 1, 2024
MEAN WELL

MEAN WELL LPV-150 Series 150W Single Output Switching Power Supply

MEAN-WELL-LPV-150-Series-150W-Single-Output-Switching-Power-Supply-
product

Product Information

Specifications

  • Model: LPV-150-12, LPV-150-15, LPV-150-24, LPV-150-36
  • DC Voltage: 12V, 15V, 24V, 36V
  • Rated Current Current Range: 10A 0 ~ 10A, 8A 0 ~ 8A, 6.3A 0 ~ 6.3A, 4.2A 0 ~ 4.2A
  • Rated Power: 120W (for most models)

Frequently Asked Questions

  • Q: What should I do if the power supply overheats?
    • A: If the power supply overheats, immediately turn it off and allow it to cool down before resuming operation. Check for proper ventilation around the unit.
  • Q: Can I use the LPV-150 series power supply outdoors?
    • A: Yes, the LPV-150 series power supply is IP67 rated, making it suitable for outdoor use. Ensure proper protection from direct exposure to water.

Features

  • Constant voltage design
  • 90 ~ 132VAC input for LPVL-150
    • 180~305VAC input for LPV-150
  • Fully encapsulated with IP67 level (Note.7)
  • Class II power unit, no FG
  • Protections: Short circuit/Overload/Over voltage/ Over temperature
  • Fully isolated plastic case
  • fanless design, cooling by free air convection
  • 100% full load burn-in test
  • Low cost, high reliability
  • Listed in UL Sign Component Manual (SAM)
  • Type “HL” for use in class I, Division 2 hazardous (Classified) location luminaires for LPVL-150
  • 2 years warranty

Applications

  • Suitable for LED related fixture or appliance (such as LED Decoration or Advertisement devices Note.10)

GTIN CODE

Description

LPV-150 and LP VL-150 are 150W single output power supplies that specifically and perfectly work for LED lighting and LED moving sign applications. As a class Il power unit, these two series are housed with the UL 94V-0 rated flame retardant plastic enclosure. The IP67 design allows every model to fit the use at dry, damp and wet locations. Both series are constant voltage mode design that various models with 12V, 15V, 24V, 36V and 48V are offered for LPV-150 where as 12V and 24V are provided for LPVL-150.

Model Encoding

MEAN-WELL-LPV-150-Series-150W-Single-Output-Switching-Power-Supply-
fig-3

SPECIFICATION

MODEL| LPV       -150-12| LPV-150-15| LPV       -150-24| LPV-150-36| LPV-150-48
---|---|---|---|---|---





OUTPUT

| DC VOLTAGE| 12V| 15V| 24V| 36V| 48V
RATED CURRENT| 10A| 8A| 6.3A| 4.2A| 3.2A
CURRENT RANGE| 0 ~ 10A| 0 ~ 8A| 0 ~ 6.3A| 0 ~ 4.2A| 0 ~ 3.2A
RATED POWER| 120W| 120W| 151.2W| 151.2W| 153.6W
RIPPLE & NOISE (max.) **Note.2| 200mVp-p| 200mVp-p| 200mVp-p| 200mVp-p| 200mVp-p
VOLTAGE TOLERANCE Note.3| ±5.0%
LINE REGULATION| ±1.0%
LOAD REGULATION| ±2.0%
SETUP, RISE TIME Note.6| LPV-150: 500ms, 50ms / 230VAC      500ms, 50ms / 277VAC;              LPVL-150: 1500ms, 50ms / 115VAC
HOLD UP TIME (Typ.)**| LPV-150: 18ms/230VAC      20ms/277VAC at full load; LPVL-150: 10ms/115VAC at full load






INPUT

| VOLTAGE RANGE Note.4| LPV-150: 180 ~ 305VAC   254 ~ 431VDC; LPVL-150: 90~132VAC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 87%| 88%| 89%| 89%| 90%
AC CURRENT| LPV-150: 1.7A/230VAC   1.5A/277VAC; LPVL-150: 3.0A/115VAC
INRUSH CURRENT

(Typ.)

| Blank type| COLD START 60A(twidth=900μs measured at 50% Ipeak) at 230VAC
L type| COLD START 75A(twidth=900μs measured at 50% Ipeak) at 115VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER| Blank type| 2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC
L type| 1 units (circuit breaker of type B) / 2 units (circuit breaker of type C) at 115VAC
LEAKAGE CURRENT| LPV-150: 0.25mA / 240VAC             LPVL-150:0.25mA / 120VAC



PROTECTION

| OVERLOAD| 110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE| 13.5 ~ 18V| 17 ~ 25V| 27 ~ 35V| 40 ~ 49V| 52 ~ 63V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after temperature goes down



ENVIRONMENT

| WORKING TEMP.| -25 ~ +65℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 40℃ for LPV-150-12,15 and LPVL-150-12,24;0~50℃ for LPV-150-24,36,48)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes




SAFETY & EMC

| SAFETY STANDARDS| Blank type| UL8750,CSA C22.2 No 250.13-12,UL879,CSA C22.2 No.207-M89,BIS IS15885(for LPV-150-12,24 only),EAC TP TC 004, IP67, IEC62368-1, BS EN/EN62368-1 approved
L type| UL8750(type”HL”),CSA C22.2 No 250.13-12,UL879,CSA C22.2 No.207-M89,IP67 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC
ISOLATION RESISTANCE| I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Blank type| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2  Class A(≤80% load), BS EN/EN61000-3-3, EAC TP TC 020
L type| Compliance to FCC part 15
EMC IMMUNITY| Blank type| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035, light industry level, EAC TP TC 020
L type| Design refer to IEC61000-4-2,3,4,5,6,8,11; light industry level


OTHERS

| MTBF| 3361.2K hrs min.       Telcordia SR-332 (Bellcore) ; 391.9Khrs min.       MIL-HDBK-217F (25℃)
DIMENSION| 1916337.5mm (LWH)
PACKING| LPV-150: 0.74Kg;20pcs/15.8Kg/0.95CUFT;            LPVL-150: 0.85Kg;20pcs/17Kg/0.95CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC(115VAC for LPVL) input, rated load and 25℃ of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance: includes set up tolerance, line regulation and load regulation.
  4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
  5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.(as available on https://[www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)](http://www.meanwell.com/Upload/PDF/EMI_statement_en.pdf))
  6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
  7. Suitable for indoor use or outdoor use without direct sunlight exposure.
  8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
  9. For any application note and IP water proof function installation caution, please refer our user manual before using. https://[www.meanwell.com/Upload/PDF/LED_EN.pdf](http://www.meanwell.com/Upload/PDF/LED_EN.pdf)
  10. This product is not intended for LED lighting luminaire applications in the EU.(In the EU the LPF/NPF/XLG series are recommended.)

※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

Case No:  LPC-150 Unit:mm

MEAN-WELL-LPV-150-Series-150W-Single-Output-Switching-Power-Supply-
fig-4

Recommend Mounting Direction

MEAN-WELL-LPV-150-Series-150W-Single-Output-Switching-Power-Supply-
fig-5

Block Diagram

PWM fosc: 47KHz

MEAN-WELL-LPV-150-Series-150W-Single-Output-Switching-Power-Supply-
fig-6

Derating Curve

MEAN-WELL-LPV-150-Series-150W-Single-Output-Switching-Power-Supply-
fig-7

Static Characteristics

MEAN-WELL-LPV-150-Series-150W-Single-Output-Switching-Power-Supply-
fig-8

User’s Manual

MEAN-WELL-LPV-150-Series-150W-Single-Output-Switching-Power-Supply-
fig-2

Documents / Resources

| MEAN WELL LPV-150 Series 150W Single Output Switching Power Supply [pdf] Owner's Manual
LPV-150 Series 150W Single Output Switching Power Supply, LPV-150 Series, 150W Single Output Switching Power Supply, Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply, Supply
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)