MEAN WELL HEP-600 Series 600W Switching Power Supply User Manual

June 1, 2024
MEAN WELL

600W Switching Power Supply for Harsh Environment
HEP-60 0 series
MEAN WELL HEP 600 Series 600W Switching Power
Supply

HEP-600 Series 600W Switching Power Supply

https://www.meanwell.com/Upload/PDF/Enclosed_Type_EN.pdf

MEAN WELL HEP 600 Series 600W Switching Power Supply - Symbol
1MEAN WELL HEP 600 Series 600W
Switching Power Supply - Symbol 2

Features

  • Universal AC input / Full range (up to 305VAC)
  • Built-in active PFC function
  • No load power consumption <0.5W at remote OFF
  • High efficiency up to 96%
  • Fanless design, cooling by free air convection
  • -40 ~ +70°C wide operating range
  • Aluminum case and filling with heat-conducted glue
  • Withstand 10G vibration test
  • Output voltage and output current can be adjusted through internal potentiometer
  • Protections: Short circuit / Over current / Over voltage / Over temperature
  • LED indicator for power on
  • Operating altitude up to 5000 meters (Note.7)
  • 6 years warranty

Applications

  • Outdoor telecommunication equipment
  • Outdoor electronic signage and billboard
  • Petroleum plant or mine shaft facility

GTINCODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

Description

HEP-600 is a 600W industrial AC/DC power supply featuring the outstanding capability to operate under highly humid, dusty, oily, and high-vibration harsh environment. The entire series is housed with the aluminum case and fully potted with heat-conducted silicone. Thanks to state-of-the-art design, the working efficiency is up to 96%, enabling HEP-600 perfectly work between -40°C and +70°C under free air convection.

Model Encoding

MEAN WELL HEP 600 Series 600W Switching Power Supply - Model
Encoding

SPECIFICATION

MODEL| HEP-600-12| HEP-600-15| HEP-600-20| HEP-600-24| HEP-600-30| HEP-600-36| HEP-600-42| HEP-600-48| HEP-600-54
---|---|---|---|---|---|---|---|---|---
 OUTPUT| DC VOLTAGE| 12V| 15V| 20V| 24V| 30V| 36V| 42V| 48V| 54V
RATED CURRENT| 40A| 36A| 28A| 25A| 20A| 16.7A| 14.3A| 12.5A| 11.2A
RATED POWER| 480W| 540W| 560W| 600W| 600W| 601.2W| 600.6W| 600W| 604.8W
RIPPLE & NOISE (max.) Note.2| 150mVp-p| 150mVp-p| 150mVp-p| 150mVp-p| 200mVp-p| 250mVp-p| 250mVp-p| 250mVp-p| 350mVp-p
VOLTAGE ADJ. RANGE| 10.2 ~ 12.6V| 12.7 ~ 15.8V| 17 ~ 21V| 20.4 ~ 25.2V| 25.5 ~ 31.5V| 30.6 ~ 37.8V| 35.7 ~ 44.1V| 40.8 ~ 50.4V| 45.9 ~ 56.7V
CURRENT ADJ. RANGE| Can be adjusted by internal potentiometer
20 ~ 40A| 18 ~ 36A| 14 ~ 28A| 12.5 ~ 25A| 10 ~ 20A| 8.3 ~ 16.7A| 7.1 ~ 14.3A| 6.2 ~ 12.5A| 5.6 ~ 11.2A
VOLTAGE TOLERANCE Note.3| ±3.0%| ±2.0%| ±1.5%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±2.0%| ±1.5%| ±1.0%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME      (Note.5)| 500ms, 80ms at full load  230VAC /115VAC
HOLD UP TIME (Typ.)| 15ms at full load  230VAC /115VAC
INPUT| VOLTAGE RANGE        Note.4| 85~264VAC(277VAC operational) 120~370VDC(390VDC  operational)
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC at full load
EFFICIENCY (Typ.)| 93%| 94%| 95%| 95%| 95.5%| 95.5%| 96%| 96%| 96%
AC CURRENT (Typ.)| 7A / 115VAC        3.3A / 230VAC        2.9A / 277VAC
INRUSH CURRENT(Typ.)| COLD START 70A(twidth=1000μs measured at 50% Ipeak) at 230VAC
LEAKAGE CURRENT| <0.75mA / 277VAC
PROTECTION| OVER CURRENT| 105 ~ 125%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT| Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE| 13 ~ 16V| 16.5 ~ 20.5V| 22 ~ 26V| 26 ~ 30V| 32.5 ~ 36.5V| 39.5 ~ 43.5V| 46 ~ 50V| 52.5 ~ 56.5V| 59 ~ 63V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, re-power on to recover
FUNCTION| REMOTE ON/OFF CONTROL| Power on : “Hi” >2 ~ 5V or Open circuit Power off : “Low” <0 ~ 0.5V or Short circuit
5V STANDBY| 5VSB : 5V@0.5A ; tolerance ±5%, ripple : 100mVp-p(max.)
ENVIRONMENT| WORKING TEMP.| -40 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 60℃)
VIBRATION| 20 ~ 500Hz, 10G 12min./1cycle, period for 72min. each along X, Y, Z axes
 SAFETY & EMC (Note.6)| SAFETY STANDARDS| UL62368-1,TUV BS EN/EN62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC  I/P-FG:2KVAC  O/P-FG:1.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, heavy industry level, EAC TP TC 020
 OTHERS| MTBF| 914.7K hrs min. Telcordia SR-332 (Bellcore) ; 76.9K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 28014448.5mm (LWH)
PACKING| 3.9Kg; 4pcs/16Kg/0.9CUFT
NOTE| 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3.Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re- confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer; For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Block Diagram

MEAN WELL HEP 600 Series 600W Switching Power Supply - Block
Diagram

Derating Curve

MEAN WELL HEP 600 Series 600W Switching Power Supply - Derating
Curve

Static Characteristics

Mechanical Specification

MEAN WELL HEP 600 Series 600W Switching Power Supply - Mechanical
Specification

※ Output voltage and constant current level can be adjusted through internal potentiometer.
(Can access by removing the rubber stopper on the case.)
AC Input Terminal Pin No. Assignment

Pin No. Assignment
1 FG ****
2 AC/L
3 AC/N

DC Output Terminal Pin No. Assignment

Pin No. Assignment Pin No. Assignment
1 RC+ 4,5 -V
2 RC- & GND 6,7 +V
3 +5VSB

Installation Manual

Please refer to : http://www.meanwell.com/manual.html
File Name:HEP-600-SPEC 2024-01-19
Downloaded from Arrow.com.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals