MEAN WELL LPS-50 Series 50W Single Output Switching Power Supply Owner’s Manual

June 1, 2024
MEAN WELL

MEAN WELL LPS-50 Series 50W Single Output Switching Power Supply

Specifications

  • Model: LPS-50 series
  • Input: Universal AC input / Full range
  • Protections: Short circuit / Overload / Over voltage
  • Cooling: Free air convection
  • Remote ON-OFF control: Built-in
  • Indicator: LED for power on
  • Burn-in test: 100% full load
  • Low profile: 23mm thickness
  • Warranty: 2 years

Product Usage Instructions:

Installation

  1. Ensure the input power matches the specifications of the power supply.
  2. Connect the output wires to the appropriate devices, observing polarity.
  3. Secure the power supply in a well-ventilated area to allow for proper cooling.

Operation

  1. Turn on the power supply using the remote ON-OFF control or switch.
  2. Monitor the LED indicator to ensure power is on.
  3. Avoid overloading the power supply beyond its rated capacity.
  4. If any protection feature is triggered, investigate and resolve the issue before reuse.

Maintenance

  1. Regularly check for dust or debris accumulation that may hinder cooling.
  2. Inspect the power supply for any physical damage or loose connections.
  3. Keep the power supply away from moisture or direct sunlight.

FAQ

  • Q: What should I do if the LED indicator does not light up?
    A: Check the input power connection and ensure it is within thespecified range. If the issue persists, contact customer support.

  • Q: Can I use the power supply with devices that have different voltage requirements?
    A: No, it is recommended to match the voltage output of the power supply with the requirements of the connected devices to avoid damage.

  • Q: How can I test if the power supply is functioning correctly?
    A: Use a multimeter to measure the output voltage of the power supply under load to verify its performance.

50W Single Output Switching Power Supply
LPS-50 series

Features

  • Universal AC input / Full range
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • Small and compact size
  • Built-in remote ON-OFF control
  • LED indicator for power on
  • 100% full load burn-in test
  • Low profile:23mm thickness
  • 2 years warranty

GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx

MEAN-WELL-LPS-50-Series-50W-Single-Output-Switching-Power-Supply-
\(2\)

SPECIFICATION

MODEL| LPS-50-3.3| LPS-50-5| LPS-50-12| LPS-50-15| LPS-50-24| LPS-50-48
---|---|---|---|---|---|---

OUTPUT

| DC VOLTAGE| 3.3V| 5V| 12V| 15V| 24V| 48V
RATED CURRENT| 10A| 10A| 4.2A| 3.4A| 2.1A| 1.1A
CURRENT RANGE| 0 ~ 12A| 0 ~ 12A| 0 ~ 5A| 0 ~ 4.1A| 0 ~ 2.5A| 0 ~ 1.3A
RATED POWER| 33W| 50W| 50.4W| 51W| 50.4W| 52.8W
PEAK LOAD(10sec.) Note.4| 39.6W| 60W| 60W| 61.5W| 60W| 62.4W
RIPPLE & NOISE (max.) **Note.2| 50mVp-p| 50mVp-p| 80mVp-p| 80mVp-p| 80mVp-p| 100mVp-p
VOLTAGE ADJ. RANGE| 3 ~ 3.6V| 4.5 ~ 5.5V| 10.8 ~ 13.2V| 13.5 ~ 16.5V| 21.6 ~ 27.2V| 43.2 ~ 52.8V
VOLTAGE TOLERANCE Note.3| ±3.0%| ±3.0%| ±2.0%| ±2.0%| ±1.0%| ±1.0%
LINE REGULATION| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LOAD REGULATION| ±3.0%| ±3.0%| ±2.0%| ±2.0%| ±1.0%| ±1.0%
SETUP, RISE TIME| 500ms, 40ms/230VAC         500ms, 40ms/115VAC at full load
HOLD UP TIME (Typ.)**| 70ms/230VAC         12ms/115VAC at full load

INPUT

| VOLTAGE RANGE| 90 ~ 264VAC         127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY(Typ.)| 75%| 81%| 82%| 84%| 85%| 86%
AC CURRENT

(Typ.)

| 115VAC| 0.9A| 1.2A
230VAC| 0.6A| 0.8A
INRUSH CURRENT (Typ.)| COLD START 18A/115VAC         35A/230VAC
LEAKAGE CURRENT| <1mA / 240VAC
PROTECTION| OVERLOAD| 122 ~ 160% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE| 3.8 ~ 4.45V| 5.75 ~ 6.75V| 13.8 ~ 16.2V| 17.25 ~ 20.25V| 27.6 ~ 32.4V| 57.6 ~ 67.2V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
FUNCTION| REMOTE ON/OFF| RC+/RC- : 0 ~ 0.8V power on ; 4 ~ 10V power off

ENVIRONMENT

| WORKING TEMP.| -20 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -20 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.04%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

SAFETY & EMC

(Note 5)

| SAFETY STANDARDS| UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, criteria A, EAC TP TC 020

OTHERS

| MTBF| 3138.2K hrs min.      Telcordia SR-332 (Bellcore) ; 491.4K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION| 1955523mm (LWH)
PACKING| 0.24Kg; 48pcs/12.5Kg/0.87CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. 33.3% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
  5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on   a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical SpecificationMEAN-WELL-LPS-50-Series-50W-Single-Output-
Switching-Power-Supply- \(3\)

AC Input Connector (CN1) : JST B5P-VH or equivalent

Pin No. Assignment Mating Housing Terminal
1 AC/L

JST VHR

or equivalent

|

JST SVH-21T-P1.1

or equivalent

2,4| No Pin
3| AC/N
5| FG| |

DC Output Connector (CN2) : JST B4P-VH or equivalent

Pin No. Assignment Mating Housing Terminal
1,2 -V JST VHR

or equivalent

| JST SVH-21T-P1.1

or equivalent

3,4| +V

Remote ON/OFF Connector(CN3):JST B2B-XH or equivalent

Pin No. Assignment Mating Housing Terminal
1 RC+ JST XHP

or equivalent

| JST SXH-001T-P0.6

or equivalent

2| RC-

: Grounding Required CN1:Pin 5 is safety ground

Block Diagram

MEAN-WELL-LPS-50-Series-50W-Single-Output-Switching-Power-Supply-
\(4\)

Derating Curve MEAN-WELL-LPS-50-Series-50W-Single-Output-Switching-
Power-Supply- \(5\)

Static Characteristics (15V)

MEAN-WELL-LPS-50-Series-50W-Single-Output-Switching-Power-Supply-
\(6\)

File Name:LPS-50-SPEC 2024-02-23
Downloaded from Arrow.com.