Specifications
- Model: LPS-50 series
- Input: Universal AC input / Full range
- Protections: Short circuit / Overload / Over voltage
- Cooling: Free air convection
- Remote ON-OFF control: Built-in
- Indicator: LED for power on
- Burn-in test: 100% full load
- Low profile: 23mm thickness
- Warranty: 2 years
Product Usage Instructions:
Installation
- Ensure the input power matches the specifications of the power supply.
- Connect the output wires to the appropriate devices, observing polarity.
- Secure the power supply in a well-ventilated area to allow for proper cooling.
Operation
- Turn on the power supply using the remote ON-OFF control or switch.
- Monitor the LED indicator to ensure power is on.
- Avoid overloading the power supply beyond its rated capacity.
- If any protection feature is triggered, investigate and resolve the issue before reuse.
Maintenance
- Regularly check for dust or debris accumulation that may hinder cooling.
- Inspect the power supply for any physical damage or loose connections.
- Keep the power supply away from moisture or direct sunlight.
FAQ
-
Q: What should I do if the LED indicator does not light up?
A: Check the input power connection and ensure it is within thespecified range. If the issue persists, contact customer support. -
Q: Can I use the power supply with devices that have different voltage requirements?
A: No, it is recommended to match the voltage output of the power supply with the requirements of the connected devices to avoid damage. -
Q: How can I test if the power supply is functioning correctly?
A: Use a multimeter to measure the output voltage of the power supply under load to verify its performance.
50W Single Output Switching Power Supply
LPS-50 series
Features
- Universal AC input / Full range
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- Small and compact size
- Built-in remote ON-OFF control
- LED indicator for power on
- 100% full load burn-in test
- Low profile:23mm thickness
- 2 years warranty
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
SPECIFICATION
MODEL| LPS-50-3.3| LPS-50-5| LPS-50-12| LPS-50-15|
LPS-50-24| LPS-50-48
---|---|---|---|---|---|---
OUTPUT
| DC VOLTAGE| 3.3V| 5V| 12V| 15V| 24V| 48V
RATED CURRENT| 10A| 10A| 4.2A| 3.4A| 2.1A| 1.1A
CURRENT RANGE| 0 ~ 12A| 0 ~ 12A| 0 ~ 5A| 0 ~ 4.1A| 0 ~ 2.5A| 0 ~ 1.3A
RATED POWER| 33W| 50W| 50.4W| 51W| 50.4W| 52.8W
PEAK LOAD(10sec.) Note.4| 39.6W| 60W| 60W| 61.5W| 60W| 62.4W
RIPPLE & NOISE (max.) **Note.2| 50mVp-p| 50mVp-p| 80mVp-p| 80mVp-p|
80mVp-p| 100mVp-p
VOLTAGE ADJ. RANGE| 3 ~ 3.6V| 4.5 ~ 5.5V| 10.8 ~ 13.2V| 13.5 ~ 16.5V|
21.6 ~ 27.2V| 43.2 ~ 52.8V
VOLTAGE TOLERANCE Note.3| ±3.0%| ±3.0%| ±2.0%| ±2.0%| ±1.0%| ±1.0%
LINE REGULATION| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LOAD REGULATION| ±3.0%| ±3.0%| ±2.0%| ±2.0%| ±1.0%| ±1.0%
SETUP, RISE TIME| 500ms, 40ms/230VAC 500ms, 40ms/115VAC at full
load
HOLD UP TIME (Typ.)**| 70ms/230VAC 12ms/115VAC at full load
INPUT
| VOLTAGE RANGE| 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY(Typ.)| 75%| 81%| 82%| 84%| 85%| 86%
AC CURRENT
(Typ.)
| 115VAC| 0.9A| 1.2A
230VAC| 0.6A| 0.8A
INRUSH CURRENT (Typ.)| COLD START 18A/115VAC 35A/230VAC
LEAKAGE CURRENT| <1mA / 240VAC
PROTECTION| OVERLOAD| 122 ~ 160% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is
removed
OVER VOLTAGE| 3.8 ~ 4.45V| 5.75 ~ 6.75V| 13.8 ~ 16.2V| 17.25 ~ 20.25V|
27.6 ~ 32.4V| 57.6 ~ 67.2V
Protection type : Hiccup mode, recovers automatically after fault condition is
removed
FUNCTION| REMOTE ON/OFF| RC+/RC- : 0 ~ 0.8V power on ; 4 ~ 10V
power off
ENVIRONMENT
| WORKING TEMP.| -20 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -20 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.04%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X,
Y, Z axes
SAFETY & EMC
(Note 5)
| SAFETY STANDARDS| UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004
approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS
EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS
EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level,
criteria A, EAC TP TC 020
OTHERS
| MTBF| 3138.2K hrs min. Telcordia SR-332 (Bellcore) ; 491.4K hrs
min. MIL-HDBK-217F (25℃)
DIMENSION| 1955523mm (LWH)
PACKING| 0.24Kg; 48pcs/12.5Kg/0.87CUFT
NOTE|
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- Tolerance : includes set up tolerance, line regulation and load regulation.
- 33.3% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
- The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Mechanical Specification
AC Input Connector (CN1) : JST B5P-VH or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|
1 | AC/L |
JST VHR
or equivalent
|
JST SVH-21T-P1.1
or equivalent
2,4| No Pin
3| AC/N
5| FG| |
DC Output Connector (CN2) : JST B4P-VH or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|
1,2 | -V | JST VHR |
or equivalent
| JST SVH-21T-P1.1
or equivalent
3,4| +V
Remote ON/OFF Connector(CN3):JST B2B-XH or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|
1 | RC+ | JST XHP |
or equivalent
| JST SXH-001T-P0.6
or equivalent
2| RC-
: Grounding Required CN1:Pin 5 is safety ground
Block Diagram
Derating Curve
Static Characteristics (15V)
File Name:LPS-50-SPEC 2024-02-23
Downloaded from Arrow.com.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>