MEAN WELL MDR-40 Series Industrial DIN Rail Power Supply Owner’s Manual

June 1, 2024
MEAN WELL

MEAN WELL MDR-40 Series Industrial DIN Rail Power Supply

Features

  • Universal AC input/Full range
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • Can be installed on DIN rail TS-35/7.5 or 15
  • Class I, Div 2 Hazardous Locations T4
  • LED indicator for power on
  • DC OK relay contact
  • No load power consumption<0.75W
  • 100% full load burn-in test
  • 3 years warranty

MEAN-WELL-MDR-40-Series-Industrial-DIN-Rail-Power-Supply-
fig-1

GTIN CODE

SPECIFICATION

MODEL MDR-40-5 MDR-40-12 MDR-40-24 MDR-40-48







OUTPUT

| DC VOLTAGE| 5V| 12V| 24V| 48V
RATED CURRENT| 6A| 3.33A| 1.7A| 0.83A
CURRENT RANGE| 0 ~ 6A| 0 ~ 3.33A| 0 ~ 1.7A| 0 ~ 0.83A
RATED POWER| 30W| 40W| 40.8W| 39.8W
RIPPLE & NOISE (max.) **Note.2| 80mVp-p| 120mVp-p| 150mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE| 5 ~ 6V| 12 ~ 15V| 24 ~ 30V| 48 ~ 56V
VOLTAGE TOLERANCE Note.3| ±2.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LOAD REGULATION| ±1.0%| ±1.0%| ±1.0%| ±1.0%
SETUP, RISE TIME Note.5| 500ms, 30ms/230VAC           500ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)**| 50ms/230VAC           20ms/115VAC at full load




INPUT

| VOLTAGE RANGE| 85 ~ 264VAC           120 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 78%| 85%| 88%| 88%
AC CURRENT (Typ.)| 1.1A/115VAC           0.7A/230VAC
INRUSH CURRENT (Typ.)| COLD START 30A/115VAC           60A/230VAC
LEAKAGE CURRENT| <1mA / 240VAC



PROTECTION

| ****

OVERLOAD

| 105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed


OVER VOLTAGE

| 6.25 ~ 7.25V| 15.6 ~ 18V| 31.2 ~ 36V| 57.6 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
FUNCTION| DC OK SIGNAL| Relay contact rating(max.): 30V/1A resistive




ENVIRONMENT

| WORKING TEMP.| -20 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| Component : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6



SAFETY & EMC

(Note 4)

| SAFETY STANDARDS| UL508, UL62368-1, TUV BS EN/EN62368-1,Class I, Div. 2 Group A, B, C, D Hazardous Locations T4, EAC TP TC 004, BSMI CNS14336-1, AS/NZS 60950.1 ,IS13252(Part1)/IEC60950-1(except 48V)approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438 Class B
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2, 3, 4, 5, 6, 8, 11, BS EN/EN55035, BS EN/EN61000-6-2, BS EN/EN61204-3, heavy industry level, EAC TP TC 020


OTHERS

| MTBF| 2418.5K hrs min.       Telcordia SR-332 (Bellcore) ; 301.7K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION| 4090100mm (WHD)
PACKING| 0.3Kg; 42pcs/13.6Kg/0.82CUFT
NOTE| 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation, and load regulation.
4. The power supply is considered a component that will be installed into the final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to an increase of the set-up time.
6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

MEAN-WELL-MDR-40-Series-Industrial-DIN-Rail-Power-Supply-
fig-2

Block Diagram

MEAN-WELL-MDR-40-Series-Industrial-DIN-Rail-Power-Supply-
fig-3

DC OK Relay Contact

  • Contact Close
    • PSU turns on / DC OK.
  • Contact Open
    • PSU turns off / DC Fail.
  • Contact Ratings (max.)
    • 30V/1A resistive load.

Derating Curve

MEAN-WELL-MDR-40-Series-Industrial-DIN-Rail-Power-Supply-
fig-4

Output Derating VS Input Voltage

MEAN-WELL-MDR-40-Series-Industrial-DIN-Rail-Power-Supply-
fig-5

References