Features:
- Constant voltage design
- Universal AC input/ Full range
- Fully encapsulated with IP67 level (Note.7)
- Withstand 300VAC surge input for 5 seconds
- Protections: Short circuit/Overload/Over voltage
- Fully isolated plastic case
- Cooling by free air convection
- 100% full load burn-in test
- Low cost, high reliability
- Suitable for LED related fixture or appliance (such as LED Decoration or Advertisement devices) (Note.11)
- 2 years warranty
SPECIFICATION
MODEL | LPV-100-5 | LPV-100-12 | LPV-100-15 | LPV-100-24 | LPV-100-36 | LPV-100-48 |
---|---|---|---|---|---|---|
OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 24V | 36V |
RATED CURRENT | 12A | 8.5A | 6.7A | 4.2A | 2.8A | 2.1A |
CURRENT RANGE | 0 ~ 12A | 0 ~ 8.5A | 0 ~ 6.7A | 0 ~ 4.2A | 0 ~ 2.8A | 0 ~ 2.1A |
RATED POWER | 60W | 102W | 100.5W | 100.8W | 100.8W | 100.8W |
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 150mVp-p |
150mVp-p
VOLTAGE TOLERANCE Note.3| ±8.0%| ±5.0%
LINE REGULATION| ±1.0%
LOAD REGULATION| ±6.0%| ±2.0%
SETUP, RISE TIME| Note.6| 2000ms, 25ms / 230VAC 2000ms, 25ms / 115VAC
HOLD UP TIME (Typ.)| 50ms/230VAC 14ms/115VAC at full load
INPUT| VOLTAGE RANGE| Note.4| 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 80%| 85%| 87%| 88%| 88%| 89%
AC CURRENT| 2.2A/115VAC 1.2A/230VAC
INRUSH CURRENT(Typ.)| COLD START 75A(twidth=700μs measured at 50% Ipeak) at
230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 2 units (circuit breaker of type B) /
3 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| 0.25mA / 240VAC
PROTECTION| OVERLOAD| 110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is
removed
OVER VOLTAGE| 5.75 ~ 6.75V| 13.8 ~ 16.2V| 17.25 ~ 20.25V| 27.6 ~ 32.4V| 41.4 ~
48.6V| 55.2 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT| WORKING TEMP.| -25 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z
axes
SAFETY & EMC| SAFETY STANDARDS| UL8750,CSA C22.2 No 250.13-12,UL879,CSA C22.2
No.207-M89,BIS IS15885(Note12),EAC TP TC 004,IP67, IEC62368-1 , BS
EN/EN62368-1 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC
ISOLATION RESISTANCE| I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2
Class A(≤80% load), BS EN/EN61000-3-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035,
light industry level, EAC TP TC 020
OTHERS| MTBF| 4497.1K hrs min. Telcordia SR-332 (Bellcore) ;| 681.6Khrs
min.| MIL-HDBK-217F (25℃)|
DIMENSION| 1905237mm (LWH)
PACKING| 0.63Kg;20pcs/13.6Kg/0.55CUFT
NOTE|
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- Tolerance : includes set up tolerance, line regulation and load regulation.
- Derating may be needed under low input voltage. Please check the static characteristics for more details.
- The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.(as available on https://[www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)](http://www.meanwell.com/Upload/PDF/EMI_statement_en.pdf))
- Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time
- Suitable for indoor use or outdoor use without direct sunlight exposure
- The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- Products sourced from the Americas regions may not have the TUV/BIS/CCC logo. Please contact your MEAN WELL sales for more information.
- For any application note and IP water proof function installation caution, please refer our user manual before using. https://[www.meanwell.com/Upload/PDF/LED_EN.pdf](http://www.meanwell.com/Upload/PDF/LED_EN.pdf)
- This product is not intended for LED lighting luminaire applications in the EU.(In the EU the LPF/NPF/XLG series are recommended.)
- R-41027766 (GZ factory) only for 12V,24V / R-62002178 (ID factory) for 5V~48V
※ Product Liability Disclaimer:For detailed information, please refer to https://[www.meanwell.com/serviceDisclaimer.aspx](http://www.meanwell.com/serviceDisclaimer.aspx)
| Arrow.com.| File Name: LPV-100-SPEC __2024-02-19
Mechanical Specification
Recommend Mounting Direction
Block Diagram
Aerating Curve
Static Characteristics