MEAN WELL RSP-500 Series Switching Power Supply Enclosed Single Output Owner’s Manual

June 1, 2024
MEAN WELL

500W Single Output with PFC Function
RSP-500 series

Dimension

L W H
230 127 40.5 (1U) mm
9.06 5 1.59 (1U) inch

https://www.meanwell.com/Upload/PDF/Enclosed_Type_EN.pdfMEAN WELL RSP-500
Series Switching Power Supply Enclosed Single Output -
ce

Features

  • Universal AC input / Full range
  • Built-in active PFC function
  • High efficiency up to 90.5%
  • Forced air cooling by built-in DC fan (Note.5)
  • Built-in remote ON-OFF control / remote sense
  • Protections: Short circuit/Overload/Over voltage/Over temperature
  • 3 years warranty

Applications

  • Factory control or automation apparatus
  • Test and measurement instrument
  • Laser related machine
  • Burn-in facility
  • RF application

GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx

Model Encoding/Order Information

MEAN WELL RSP-500 Series Switching Power Supply Enclosed Single Output -
rsp

SPECIFICATION

MODEL| RSP-500-3.3| RSP-500-4| RSP-500-5| RSP-500-12| RSP-500-15| RSP-500-24| RSP-500-27| RSP-500-48
---|---|---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 3.3V| 4V| 5V| 12V| 15V| 24V| 27V| 48V
RATED CURRENT| 90A| 90A| 90A| 41.7A| 33.4A| 21A| 18.6A| 10.5A
CURRENT RANGE| 0 – 90A| 0 – 90A| 0 – 90A| 0 – 41.7A| 0 – 33.4A| 0 – 21A| 0 – 18.6A| 0 – 10.5A
RATED POWER| 297W| 360W| 450W| 500.4W| 501W| 504W| 502.2W| 504W
RIPPLE & NOISE (max.) Note.2| 120mVp-p| 120mVp-p| 150mVp-p| 150mVp-p| 150mVp-p| 150mVp-p| 150mVp-p| 150mVp-p
VOLTAGE ADJ. RANGE| 2.8 – 3.6V| 3.6 – 4.3V| 4.5 – 5.5V| 10 – 13.2V| 13.5 – 18V| 20 – 26.4V| 26 – 30V| 41 – 56V
VOLTAGE TOLERANCE Note.3| ±2.0%| ±2.0%| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.3%| ±0.3%| ±0.2%| ±0.2%| ±0.2%
LOAD REGULATION| ±1.0%| ±1.0%| ±1.0%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 1500ms, 80ms/230VAC 3000ms, 80ms/115VAC at full load
HOLD UP TIME (Typ.)| 18ms/230VAC 14ms/115VAC at full load
INPUT| VOLTAGE RANGE Note.4| 85 – 264VAC 120 – 370VDC
FREQUENCY RANGE| 47 – 63Hz
POWER FACTOR (Typ.)| PF>0.95/230VAC PF>0.98/115VAC at full load
EFFICIENCY (Typ.)| 81%| 183%| 84%| 188%| 188%| 189%| 190.%| 191.%
AC CURRENT (Typ.)| 4.2Af115VAC 2.1 A/230VAC| 5.3A/115VAC 2.65 A/230VAC
INRUSH CURRENT (Typ.)| 20A/115VAC 40A/230VAC
LEAKAGE CURRENT| <2mA/ 240VAC
PROTECTION| OVERLOAD| 105 -130% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE| 3.8 – 4.5V| 4.5 – 5.3V| 15.75 – 6.75V| 113.8 – 16.2V| 18.8 – 21.8V| 27.6 – 32.4V| 132.9 – 38.3V| 158.4 – 68V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION| REMOTE CONTROL| POWER ON:open or 0-0.8VDC between RC+(Pin 4)&RC-(Pin3) on CN100 POWER OFF: 4-10VDC between RC+(Pin 4)&RC-(Pin3) on CN100
REMOTE SENSE| Compensate voltage drop on the load wiring up to 0.3V
FAN CONTROL (Typ.)| RTH250°C± 10°C Fan on ; RTH240°C±10°C Fan off (Fan always on for 3.3-SV,Fan ON/OFF control for 12-48V)
ENVIRONMENT| WORKING TEMP.| -30 – +70°C (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 – 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 – +85°C, 10 – 95% RH
TEMP. COEFFICIENT| ±0.03%/°C (0 – 50°C)
VIBRATION| 10 – 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY &
EMC (Note.4)| SAFETY STANDARDS| UL62368-1, TUV BS EN/EN62368-1, AS/NZS 62368.1, EAC TP TC 004 , CCC GB4943.1 . BSMI CNS14336-1approved
WITHSTAND VOLTAGE| I/P-0/P:3KVAC IIP-FG:2KVAC 0/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-0/P, I/P-FG, 0/P-FG:100/1 Ohms / 500VDC / 25°C / 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS ENIEN61000-3-2,-3, EAC TP TC 020,G8/T 9254, CNS13438 Class B
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2, EAC TP TC 020
OTHERS| MTBF| 1372.4K hrs min. Telcordia SR-332 (Bellcore) ; 187.9K hrs min. MIL-HDBK-217F (25°C)
DIMENSION| 23012740.5mm (L’W*H)
PACKING| 1.3Kg; 9pcs112.7Kg10.7CUFT
NOTE| 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance. line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the derating curve for more details.
5. Fan always on for 3.3-5V.Fan ON/OFF control for 1 2-48V.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
7. The ambient temperature derating of 3.5 C/1000m with fanless models and of 5C/1000m with fan models for operating altitude higher than 2000m(6500ft).
,%:.: Product Liability Disclaimer : For detailed information. please refer to https://www.meanwell.com/serviceDisclaimeraspx

Mechanical Specification

MEAN WELL RSP-500 Series Switching Power Supply Enclosed Single Output -
Specification

Block Diagram

MEAN WELL RSP-500 Series Switching Power Supply Enclosed Single Output -
Diagram

Derating Curve

MEAN WELL RSP-500 Series Switching Power Supply Enclosed Single Output -
Curve

Static Characteristics

Function Description of CN100

Pin No. Function Description
1 -S Negative sensing. The -S signal should be connected to the negative

terminal of the load. The -S and +S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.3V.
2| +S| Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.3V.
3| RC-| Return for RC+ signal input.
4| RC+| Turns the output on and off by electrical or dry contact between pin 4 ( RC+) and pin 3 (RC-). 0-0.8VDC or open: Power ON, 4-10VDC: Power OFF.

Function Manual

  1. Remote Control
    The PSU can be turned ON/OFF by using the “Remote Control” function.Between RC-(pin3) and RC+(pin4) on CN100| PSU Status
    ---|---
    SW OFF (0 ~ 0.8VDC) or open| ON
    SW ON (4 ~ 10V)| OFF

MEAN WELL RSP-500 Series Switching Power Supply Enclosed Single Output -
Function

  1. Remote Sense
    The remote sensing compensates voltage drop on the load wiring up to 0.3VMEAN WELL RSP-500 Series Switching Power Supply Enclosed Single Output -
Remote Sense

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals