MEAN WELL APC-16 Series 16W Single Output Switching Power Supply
OWNNER’S MANUAL
GTIN CODE
https://www.meanwell.com/serviceGTIN.aspx
FEATURES:
- Constant current mode design
- Universal AC input/ Full range
- Protections :Short circuit/ Over voltage
- Fully isolated plastic case
- Small and compact size
- Cooling by free air convection
- Class II power unit, no FG
- Class 2 power unit
- Pass LPS
- IP42 design
- Suitable for LED related fixture or appliance (such as LED Decoration or Advertisement devices)(Note.6)
- 100% full load burn-in test
- Low cost/ High reliability
- 2 years warranty
SPECIFICATION
MODEL | APC-16-350 | APC-16-700 |
---|---|---|
OUTPUT | RATED CURRENT | 350mA |
DC VOLTAGE RANGE | 12-48V | 9-24V |
RATED POWER | 16.8W | 16.8W |
RIPPLE & NOISE (max.) Note.2 | 300mVp-p | 250mVp-p |
VOLTAGE TOLERANCE Note.3 | ±5.0% | |
CURRENT ACCURACY | ±8.0% | |
LINE REGULATION | ±1.0% | |
LOAD REGULATION | ±3.0% | |
SETUP, RISE TIME | 3000ms, 200ms I 230VAC 3000ms, 200ms I 115VAC atfull |
load
HOLD UP TIME (Typ.)| 20ms/230VAC 12ms/115VAC atfull load
INPUT| VOLTAGE RANGE Note.4| 90 – 264VAC 127- 370VDC
FREQUENCY RANGE| 47 – 63Hz
EFFICIENCY(Typ.)| 84%| 83%
AC CURRENT| 0.3A/230VAC;0.5A/115VAC
INRUSH CURRENT(Typ.)| COLD START 45A(twidth=210µs measured at 50% Ipeak) at
230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 13 units (circuit breaker of type B)
/ 23 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| 0.25mA I 240VAC
PROTECTION| OVER VOLTAGE| 50.4- 60V| 27.6- 33.5V
Protection type: Shut off o/p voltage, clamping by zener diode
ENVIRONMENT| WORKING TEMP.| -30 – 70°C (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 – 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 – +80°C, 10 – 95% RH
TEMP. COEFFICIENT| ±0.2%/°C (0 – 50°C)
VIBRATION| 10 – 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y,
Z axes
SAFETY &
EMC
(Note 5)| SAFETY STANDARDS Note.7| UL8750,CSA C22.2 No.250.0-08, BIS IS15885,
EAC TP TC 004,BS EN/EN 62368-1 approved
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC
ISOLATION RESISTANCE| I/P-O/P:>100M Ohms/ 500VDC / 25°C/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032,BS EN/EN61000-3-2,BS EN/EN61000-3-3,
EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN55035,BS EN/EN61000-4-2,3,4,5,6,8,11;
light industry level(surge 2KV), EAC TP TC 020
OTHERS| MTBF| 6411.4K hrs min. Telcordia SR-332 (Bellcore); 1092.9K
hrs min. MIL-HDBK-217F (25°C)
DIMENSION| 77’40’29(L ‘W’H)
PACKING| 0.1Kg; 120pcs/14Kg/1.06CUFT
NOTE| 1. All parameters NOT specially mentioned are measured at 230VAC input,
rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted
pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load
regulation.
4. Derating may be needed under low input voltage. Please check the static
characteristic for more details.Please connect L line to the positive pole and
N line to the negative pole under DC input.
5. The power supply is considered as a component that will be operated in
combination w[h final equipment. Since EMC performance will be affected by
the complete installation, the final equipment manufacturers must re-qualify
EMC Directive on the complete installation again.
(as available on https://www.meanwell.com//Upload/PDF/EMl_statement_en.pdf)
6. This product is not intended for LED lighting luminaire applications in
the EU.(ln the EU the LPF/NPF/XLG series are recommended.)
7. The model certified for CCC(GB19510.14, GB19510.1, GB17743 and GB17625.1)
is an optional model. Please contact MEAN WELL for details.
8. The ambient temperature derating of 3.5°C/1000m with fanless models and
of S°C/1000m w[h fan models for operating altitude higher than 2000m(6500ft).
9. For any application note and IP water proof function installation caution,
please refer our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
Product Liabil[y Disclaimer : For detailed information, please refer to
https://www.meanwell.com/serviceDisclaimer.aspx
Mechanical Specification
Block Diagram
Derating Curve
Static Characteristics
Product Specifications
-
Model: APC-16-350, APC-16-700
-
Output:
- Rated Current: 350mA
- DC Voltage Range: 12~48V
- Rated Power: 16.8W
- Ripple & Noise (max.): 300mVp-p
- Current Accuracy: 700mA 9~24V 16.8W 250mVp-p
-
Input:
- Voltage Range: 90 ~ 264VAC, 127 ~ 370VDC
- Frequency Range: 47 ~ 63Hz
- Efficiency: 84%, 83%
-
Protection:
- Over Voltage Protection: 50.4~60V
- Working Temperature: -30 ~ 70°C
-
Others:
-
Safety Standards: UL8750, CSA C22.2 No.250.0-08, BIS IS15885,
EAC TP TC 004, BS EN/EN 62368-1 approved -
EMC Compliance: BS EN/EN55032, BS EN/EN61000-3-2, BS
EN/EN61000-3-3, EAC TP TC 020 -
MTBF: 6411.4K hrs min.
-
Product Usage Instructions
Installation
- Ensure input voltage is within the specified range.
- Connect the L line to the positive pole and the N line to the negative pole under DC input.
- Place the power supply in a well-ventilated area with sufficient clearance for heat dissipation.
Operation
- Apply the appropriate load within the rated current and voltage range.
- Monitor for any abnormal behavior such as excessive noise or voltage fluctuations.
Maintenance
- Regularly check for any signs of damage or wear on the power supply unit.
- Keep the unit clean and free from dust accumulation to prevent overheating.
Downloaded from Arrow.com.
Frequently Asked Questions (FAQ)
1. What should I do if the power supply overheats?
If the power supply overheats, immediately disconnect it from the power source and allow it to cool down before attempting to use it again.
2. Can I connect multiple devices to this power supply?
The maximum number of power supplies that can be connected on a 16A circuit breaker varies based on the type of circuit breaker and input voltage. Refer to the manual for specific details.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>