Features

  • Global certificates
  • Universal AC input / Full range
  • 3 pole AC inlet IEC320-C14,Class power unit
  • No load power consumption< 0.075W
  • Energy efficiency Level VI
  • Comply with EISA 2007/DoE,NRCan,Korea K-MEPS, AU/NZ MEPS,EU ErP and CoC Version 5
  • Protections: Short circuit / Overload / Over voltage
  • Fully enclosed plastic case
  • Pass LPS
  • -30~+70 ℃ wide range working temperature
  • LED indicator for power on
  • Various DC plug quick adapter accessory available (Plug kit sold sperately, please refer to : https://www.meanwell.com/upload/pdf/DC_plug.pdf )
  • 3 years warranty

Applications

  • Consumer electronic devices
  • Telecommunication devices
  • Office facilities
  • Industrial equipments

■ GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx

Description

GST40A is a highly reliable, 40W desktop style single-output green adaptor series. This product is a classⅠ power unit (with FG), equipped with a standard IEC320-C14 AC inlet and adopting the input range from 90VAC to 264VAC. The entire series supplies different models with output voltages ranging between 5VDC and 48VDC that can satisfy the demands for various types of consumer electronic devices.
With the efficiency up to 92% and the extremely low no-load power consumption below 0.075W,GST40A is compliant with USA EISA 2007/DoE,Canada NRCan,Australia and New Zealand MEPS, Korea K-MEPS,EU ErP and Code of Conduct (CoC) Version 5. The supreme feature allows the adaptor to save the energy when it is either under the operating mode or the standby mode. The entire series utilizes the 94V-0 flame retardant plastic case.GST40A is certified for the international safety regulations.

■ Model Encoding

MEAN WELL GST 40 A 18 GST40A External Desktop Adaptor Switching Power
Supplies - mode

SPECIFICATION

ORDER NO.| GST40A05-P1J| GST40A07-P1J| GST40A09-P1J| GST40A12-P1J| GST40A15-P1J| GST40A18-P1J| GST40A24-P1J| GST40A48-P1J
---|---|---|---|---|---|---|---|---








OUTPUT

| SAFETY MODEL NO.| GST40A05| GST40A07| GST40A09| GST40A12| GST40A15| GST40A18| GST40A24| GST40A48
DC VOLTAGE Note.2| 5V| 7.5V| 9V| 12V| 15V| 18V| 24V| 48V
RATED CURRENT| 5A| 5.34A| 4.45A| 3.34A| 2.67A| 2.22A| 1.67A| 0.84A
CURRENT RANGE| 0 ~ 5A| 0 ~ 5.34A| 0 ~ 4.45A| 0 ~ 3.34A| 0 ~ 2.67A| 0 ~ 2.22A| 0 ~ 1.67A| 0 ~ 0.84A
RATED POWER (max.)| 25W| 40W| 40W| 40W| 40W| 40W| 40W| 40W
RIPPLE & NOISE (max.) **Note.3| 120mVp-p| 120mVp-p| 120mVp-p| 120mVp-p| 120mVp-p| 120mVp-p| 150mVp-p| 200mVp-p
VOLTAGE TOLERANCE Note.4| ±5.0%| ±5.0%| ±5.0%| ±3.0%| ±3.0%| ±3.0%| ±2.5%| ±2.5%
LINE REGULATION Note.5| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LOAD REGULATION| ±5.0%| ±5.0%| ±5.0%| ±3.0%| ±3.0%| ±3.0%| ±2.5%| ±2.5%
SETUP, RISE TIME Note.6| 1000ms, 50ms / 230VAC         1000ms, 50ms / 115VAC at full load
HOLD UP TIME (Typ.)**| 50ms / 230VAC        15ms / 115VAC at full load




INPUT

| VOLTAGE RANGE| 90 ~ 264VAC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 84.5%| 87.5%| 88.5%| 89.5%| 90%| 90%| 91%| 92%
AC CURRENT (Typ.)| 1A / 115VAC        0.5A / 230VAC
INRUSH CURRENT (max.)| Cold start  35A / 115AC       65A / 230VAC
LEAKAGE CURRENT(max.)| 0.75mA / 240VAC



PROTECTION

| ****

OVERLOAD

| 105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed


OVER VOLTAGE

| 5.2 ~ 6.8V| 7.8 ~ 10.2V| 9.4 ~ 12.2V| 12.6 ~ 16.2V| 15.7 ~ 20.3V| 18.9 ~ 24.3V| 25.2 ~ 32.4V| 50.4 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover




ENVIRONMENT

| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03% / ℃ (0~50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes















SAFETY & **EMC (Note. 9)**

| SAFETY STANDARDS Note. 7| UL62368-1, CSA C22.2 No.62368-1, TUV BS EN//EN62368-1, BSMI CNS 14336-1 , CCC GB4943.1, PSE J62368-1, AS/NZS 60950.1,BIS IS13252, KC K60950-1, EAC TP TC 004 approved; SIRIM MS IEC60950-1 (optional) approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH






EMC EMISSION

| Parameter| Standard| Test Level / Note


Conducted emission

| BS EN/EN55032(CISPR32),FCC PART 15 / CISPR22 CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1 EAC TP TC 020,MSIP KN32| ****

Class B


Radiated emission

| BS EN/EN55032(CISPR32),FCC PART 15 / CISPR22 CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1 EAC TP TC 020,MSIP KN32| ****

Class B

Harmonic current| BS EN/EN61000-3-2,GB9254| Class A
Voltage flicker| BS EN/EN61000-3-3| ——-







EMC IMMUNITY

| BS EN/EN55035
Parameter| Standard| Test Level /Note
ESD| BS EN/EN61000-4-2| Level 4, 15KV air; Level 4, 8KV contact
RF field susceptibility| BS EN/EN61000-4-3| Level 2, 3V/m
EFT bursts| BS EN/EN61000-4-4| Level 2, 1KV
Surge susceptibility| BS EN/EN61000-4-5| Level 3, 1KV/Line-Line , 2KV/Line-FG
Conducted susceptibility| BS EN/EN61000-4-6| Level 2, 3V
Magnetic field immunity| BS EN/EN61000-4-8| Level 2, 3A/m
Voltage dips , interruption| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30% dip 25 periods,

>95% interruptions 250 periods

**OTHERS| MTBF| 3493.6K hrs min.     Telcordia SR-332 (Bellcore) ; 728.2K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION| 1255031.5mm (LWH)
PACKING| 0.28Kg; 40pcs/12.02Kg/1.04CUFT
****
CONNECTOR| PLUG| See page 4~5 ; Other type available by customer requested
CABLE| See page 4~5 ; Other type available by customer requested
****
NOTE**| 1. All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient.
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3. Ripple & noise are measured at 20MHz by using a 12″ twisted pair terminated with a 0.1μF & 47μF capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The demand for Malaysia safety is processed with the order no. GST40A -SIRIM by request. Please contact MEAN WELL for details.
8.  The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
9. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

MEAN WELL GST 40 A 18 GST40A External Desktop Adaptor Switching Power
Supplies - echanical Specification

◎ DC plug changeable through:
(1) Customization of the standard part with an optional DC plug according to the table (MOQ applicable)
(2) Quick adapter accessory (sold separately without MOQ) Please refer to below table and online selection guide :
https://www.meanwell.com/upload/pdf/DC_plug.pdf
Example quick adapter accessory:

◎ Optional DC plug: (Available in customized cable or quick adapter)
MEAN WELL GST 40 A 18 GST40A External Desktop Adaptor Switching Power
Supplies - tableMEAN WELL GST 40 A 18 GST40A External Desktop Adaptor Switching
Power Supplies - table1

Installation Manual

Please refer to : http://www.meanwell.com/manual.html

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals