Schneider Electric 690 Wiser Underfloor Heating Connection Strip User Guide
- June 1, 2024
- Schneider Electric
Table of Contents
- Schneider Electric 690 Wiser Underfloor Heating Connection Strip
- Product Specifications
- Product Usage Instructions
- Frequently Asked Questions
- Safety Information
- About the device
- Installing the device
- Setting floor sensor limit
- Identifying the device
- Using the device
- Editing an automation
- Settings
- Troubleshooting
- Declaration of Conformity
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Schneider Electric 690 Wiser Underfloor Heating Connection Strip
Product Specifications
- Product Name: Wiser Underfloor Heating Connection Strip
- Brand: Schneider Electric
- Functionality: Underfloor heating connection strip
- Release Date: 04/2024
- Website: www.se.com
Product Usage Instructions
Safety Information:
It is important to read and understand the safety information provided in the user manual before attempting to install, operate, service, or maintain the device. Failure to follow safety instructions may result in personal injury or death.
Installation:
- Ensure the power source is turned off before installation.
- Follow the provided installation guide for proper setup.
- Connect the underfloor heating system to the connection strip as per the instructions.
Operation:
Once installed, ensure the device is properly connected and functioning correctly.
Maintenance:
Regular maintenance checks are recommended to ensure optimal performance of the underfloor heating system.
Troubleshooting:
If you encounter any issues with the device, refer to the troubleshooting section of the user manual for guidance.
Frequently Asked Questions
- Q: What should I do if the device is not heating up?
- A: Check the power supply, connections, and settings to ensure everything is properly configured. If issues persist, contact customer support for further assistance.
- Q: Can I use the connection strip with other brands of underfloor heating systems?
- A: It is recommended to use the connection strip with compatible underfloor heating systems from Schneider Electric for optimal performance and compatibility.
Wiser Underfloor Heating Connection Strip
Device user guide
Information about features and functionality of the device. 04/2024
www.se.com
Legal Information
The information provided in this document contains general descriptions,
technical characteristics and/or recommendations related to
products/solutions.
This document is not intended as a substitute for a detailed study or
operational and site-specific development or schematic plan. It is not to be
used for determining suitability or reliability of the products/solutions for
specific user applications. It is the duty of any such user to perform or have
any professional expert of its choice (integrator, specifier or the like)
perform the appropriate and comprehensive risk analysis, evaluation and
testing of the products/solutions with respect to the relevant specific
application or use thereof.
The Schneider Electric brand and any trademarks of Schneider Electric SE and
its subsidiaries referred to in this document are the property of Schneider
Electric SE or its subsidiaries. All other brands may be trademarks of their
respective owner.
This document and its content are protected under applicable copyright laws
and provided for informative use only. No part of this document may be
reproduced or transmitted in any form or by any means (electronic, mechanical,
photocopying, recording, or otherwise), for any purpose, without the prior
written permission of Schneider Electric.
Schneider Electric does not grant any right or license for commercial use of
the document or its content, except for a non-exclusive and personal license
to consult it on an “as is” basis.
Schneider Electric reserves the right to make changes or updates with respect
to or in the content of this document or the format thereof, at any time
without notice.
To the extent permitted by applicable law, no responsibility or liability is
assumed by Schneider Electric and its subsidiaries for any errors or omissions
in the informational content of this document, as well as any non-intended use
or misuse of the content thereof.
DUG_Underfloor Heating Connection Strip_WH-03
3
Safety Information
Safety Information
Important Information
Read these instructions carefully and look at the equipment to become familiar
with the device before trying to install, operate, service, or maintain it.
The following special messages may appear throughout this manual or on the
equipment to warn of potential hazards or to call attention to information
that clarifies or simplifies a procedure.
The addition of either symbol to a “Danger” or “Warning” safety label
indicates that an electrical hazard exists which will result in personal
injury if the instructions are not followed.
This is the safety alert symbol. It is used to alert you to potential personal
injury hazards. Obey all safety messages that accompany this symbol to avoid
possible injury or death.
DANGER
DANGER indicates a hazardous situation which, if not avoided, will result in
death or serious injury. Failure to follow these instructions will result in
death or serious injury.
WARNING
WARNING indicates a hazardous situation which, if not avoided, could result in
death or serious injury.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided, could result in
minor or moderate injury.
NOTICE
NOTICE is used to address practices not related to physical injury.
4
DUG_Underfloor Heating Connection Strip_WH-03
Wiser Underfloor Heating Connection Strip
Wiser Underfloor Heating Connection Strip
CCTFR6600 (Wiser UFH Connection Strip (Heat/Cool))
For your safety
NOTICE
RISK OF DAMAGE TO DEVICE Always operate the product in compliance with the
specified technical data. Failure to follow these instructions can result in
equipment damage.
About the device
The Wiser Underfloor Heating Connection Strip (hereinafter called Underfloor
Heating (UFH)) is used to control thermal actuator valve heads to regulate the
flow of hot water in the underfloor pipes. The UFH Heat/Cool can also be used
to control a heat pump or a boiler. The UFH should only be used with hydronic
UFH systems. It works in conjunction with the Wiser Hub and Wiser room
thermostats, and it controls the temperature for individual rooms/zones.
TIP: There are total 6 channels available on Underfloor Heating, based on your
rooms/zones requirement select the channel:
· 1/2 channel: you can use it for a large room to control 4 thermal actuators
valve heads to supply hot water.
· 3/4 channel: you can use it for a medium room to control 2 thermal actuators
valve heads to supply hot water.
· 5/6 channel: you can use it for a small room to control a thermal actuator
valve head to supply hot water.
With mixed systems (UFH and radiators) Wiser radiator thermostats can be
added, and in this way a complete hydronic heating system can be controlled.
The system is simple to expand: 2 further Wiser Connection Strips (and
optionally radiator thermostats) can be added. 1x UFH max. 6 rooms/zones 2x
UFH max. 12 rooms/zones 3x UFH max. 16 rooms/zones
Features of the Underfloor Heating: · Remotely control Underfloor Heating
using the Wiser Home app. · Boost the room temperature using the Wiser Room
Thermostat center button.
DUG_Underfloor Heating Connection Strip_WH-03
5
Diagram of operating elements
A. Setup button
B. Setup LED
C. Channel button
D. Cooling LED
E. Room names
F. Channel LEDs 1 to 6
G. LED for pump contact
H. LED for burner or boiler
I. LED for 230 V / 24 V power supply
A BC D
E
F
Wiser Underfloor Heating Connection Strip
GH I
Installing the device
Refer to the installation instruction supplied with this product.
6
DUG_Underfloor Heating Connection Strip_WH-03
Wiser Underfloor Heating Connection Strip
Pairing the device
Using the Wiser Home app, pair your Underfloor Heating with the Wiser Hub to
access and control the Underfloor Heating.
IMPORTANT: Make sure all Underfloor Heating devices are wired and powered
before proceeding.
1. On the Home page, tap .
2. Tap Devices > 3. Tap Next.
and tap Climate (tab) > Underfloor Connection Strip.
Next
4. Press and hold the setup button until the LED flashes green.
NOTE: In the app screen, shows the process of joining the Underfloor Heating.
DUG_Underfloor Heating Connection Strip_WH-03
7
Wiser Underfloor Heating Connection Strip
5. Please wait for a few seconds until Underfloor Heating is successfully
joined. In the app, you can see the Underfloor Heating is successfully joined.
6. Enter the Device name and tap Submit to complete the pairing process if Underfloor Heating system is without cooling input. If the Underfloor Heating system is with cooling input, tap Next and continue below steps.
UFH system without cooling input
UFH system with cooling input
Name
Name Next
8
DUG_Underfloor Heating Connection Strip_WH-03
Wiser Underfloor Heating Connection Strip
7. Turn on the Cooling Input toggle switch to use cooling features in the app, such as the ability to set a cooling schedule. IMPORTANT: Skip Step 8 if you are using Wiser Hub. If you are using Wiser HubR, continue to Step 8.
Wiser Hub
Wiser HubR
?
?
8. Tap Boiler Contact to select the type of relay connected. TIP: If UFH is
directly controlling the boiler, select “UFH Relay” for the Boiler Contact
option. In case the boiler is controlled by a Wiser Hub with relay, then
select Wiser Hub Relay for this option.
9. Tap Submit to complete the pairing process.
You can see the added Underfloor Heating on the Home page under the room tab
or under ALL devices.
DUG_Underfloor Heating Connection Strip_WH-03
9
Configuring the device
Wiser Underfloor Heating Connection Strip
Renaming the device
Using the Wiser Home app, you can rename the Underfloor Heating.
1. On the Home page, tap . 2. Tap Devices > Underfloor Heating > Device Name
(A) to rename the
Underfloor Heating.
A
Delete
Assigning a channel to the room
Using the Wiser Home app, you can assign Underfloor Heating channel to the
room to control the temperature. Select one or several channels based on your
room size or the number of thermal actuators fitted (such as for a small room:
channel 5 or 6, a large room: channel 1 or 2).
· Channels 1 and 2 can be fitted with 4x thermal actuators each. · Channels 3
and 4 can be fitted with 2x thermal actuators each. · Channels 5 and 6 can be
fitted with 1x thermal actuator each. 1. On the Home page, tap . 2. Tap
Devices > Underfloor Heating
10
DUG_Underfloor Heating Connection Strip_WH-03
Wiser Underfloor Heating Connection Strip 3. Tap Channel configuration and select the Channel for which you want to assign a room.
4. Select a existing room from the list or enter New room name then tap
Submit
Setting Floor Sensor Location
Using the Wiser Home app, you can set the floor sensor location. Precondition:
Assign channel to the room, page 10. To set the floor sensor location:
1. On the Home page, tap . 2. Tap Devices > Underfloor Heating > Floor Sensor
Location (A) to select
Unassigned or Z if the floor sensor is connected. TIP: Z is the name of the
room where the Room thermostat is located (you can give any name while
assigning the Room thermostat to the room).
3. Tap Ok
A
Delete
Z
OK
B
Delete
DUG_Underfloor Heating Connection Strip_WH-03
11
Wiser Underfloor Heating Connection Strip
Setting floor sensor limit
Using the Wiser Home app, you can set the floor sensor limit for Underfloor
Heating.
1. On the Home page, tap . 2. Tap Devices > Underfloor Heating 3. Select the
following:
Floor Sensor Upper Limit: to set upper temperature limit of the floor
sensor.
Floor Sensor Lower Limit: to set lower temperature limit of the floor
sensor.
Delete
NOTE: · Floor sensor upper limit temperature should be higher than lower limit
temperature. · Floor sensor lower limit temperature should be lower than upper
limit temperature. · The UFH setpoint temperature ranges from 18°C to 30 °C.
Enabling cooling input
Using the Wiser Home app, you can enable cooling input for Underfloor Heating
to use cooling features in the app, such as the ability to set a cooling
schedule.
1. On the Home page, tap . 2. Tap Devices > Underfloor Heating
12
DUG_Underfloor Heating Connection Strip_WH-03
Wiser Underfloor Heating Connection Strip 3. Turn on the Cooling Input toggle switch.
Delete
IMPORTANT: If UFH channel is assigned to any of the following heating device,
make sure in Room Setting > Excluded From Cooling toggle switch is On. This
can be useful if there are areas in a building that do not require cooling,
such as storage rooms or unoccupied spaces.
· Connected Thermostat 2 A (for Preset P1 and P2) · Connected Thermostat 16 A
(for all Preset)
F
Delete
Identifying the device
Using the Wiser Home app, you can identify the Underfloor Heating from the
other available devices in the room. To identify the Underfloor Heating:
1. On the Home page, tap .
DUG_Underfloor Heating Connection Strip_WH-03
13
Wiser Underfloor Heating Connection Strip 2. Tap Devices > Underfloor Heating
Identify (A) to rename the Underfloor
Heating. NOTE: · This feature flashes the Underfloor Heating LEDs, so you can identify the actual device. · The Underfloor Heating LEDs will continue to flash until you tap OK.
A
Delete
14
DUG_Underfloor Heating Connection Strip_WH-03
Wiser Underfloor Heating Connection Strip
Using the device
Setting the room temperature using the app
Using the Wiser Home app, you can adjust, set or boost the room temperature.
Precondition: Add a Wiser Room Thermostat in the same room where 16A Relay is
located. To adjust, set or boost the room temperature:
1. On the Home screen, select device from the room tab or All tab.
Heating
Back
LiviHnog mReoom
24.0
18
Follow Schedule Edit Schedule Room Settings
Follow schedule Edit schedule Room settings
2. Use the slider control on the right of the screen to adjust the
temperature.
Tap to set the boost time. TIP: You can Boost the room temperature using the
Wiser Room Thermostat center button. Boost can be stopped at any time by
tapping the and selecting it off.
NOTE:
· The indicates that the room temperature is below the desired temperature (set point), so the heating is on.
· The indicates that the room temperature is above the desired temperature (set point), so the heating is off.
· The indicates that the room temperature is higher than the desired temperature (set point), so the cooling is on.
· The indicates that the room temperature is lower than desired temperature (set point), so the cooling is off.
· The / indicates that the floor temperature sensor is configured and when the upper/lower limits are reached the room screen will show the floor limit icons.
DUG_Underfloor Heating Connection Strip_WH-03
15
Wiser Underfloor Heating Connection Strip
Emergency Heating
You can do emergency heating manually by pressing the channel button if the
Hub is not working or when the Wiser Home app is not responding. Follow the
steps below to do an emergency heating.
1. Press and hold the Channel Button for >2 seconds.
2. Press Channel Button again to select further channels. The selected
channel LED will start flashing.
3. When the required channel LED is flashing, press and hold for >2 seconds.
This LED will be solid green and the next channel LED will flash. You can
select and channel combination, e.g., Channels 1, 3 and 5.
4. Pressing on channel 6 activates the selected channels. The relevant LEDs
will flash green and the actuators open to allow water flow. After 4 hours an
emergency heating stops. The emergency heating can also be stopped by pressing
channel button. If multiple Wiser UFH Connection Strips are being used this
test can be carried out on all connection strips.
Channel Button Channel LED
Channel 1
Wiser
1 to 6 Channels
Schneider
Electric
16
DUG_Underfloor Heating Connection Strip_WH-03
Wiser Underfloor Heating Connection Strip
Creating a moment
Moment allows you to group multiple actions that are usually performed
together. By using the Wiser Home app, you can create moments based on your
needs. To create a moment:
1. On the Home page, tap .
2. Go to Moments > to create a moment. 3. Enter the name of the moment (A).
TIP: You can choose the cover image that best represents your moment by
tapping .
4. Tap Add actions (B) to select the list of devices.
Close
Moment creator
Save
Name e.g. Movie Night
A
Actions
Add actions
0 of 60
B
5. In the Add actions menu, you can select the devices (C).
Select devices
All Test
Connected Socket
Three
C
Heater 1
Done
6. Once all the device are selected, tap Done.
DUG_Underfloor Heating Connection Strip_WH-03
17
Wiser Underfloor Heating Connection Strip
7. On the Moment creator page, tap the device to set the condition. For example, select heating. Set the required temperature using sliding bar (D).
Back
Heating
Set
D
When the desired condition is set, tap Set. 8. Once all conditions are set,
tap Save.
Once the moment is saved, it is visible on the Moments tab. You can tap on the
moment to enable it.
18
DUG_Underfloor Heating Connection Strip_WH-03
Wiser Underfloor Heating Connection Strip
Editing a moment
1. On the Home page, tap .
2. Go to Moments, locate the moment you want to edit and tap . 3. On the
Moment editor page, you can perform following changes:
· Change the icon . · Rename the moment. · Tap each action to change the
settings.
To remove an action, slide the action to the left and then tap delete it.
Tap Add actions (B) to add new action.
(A) to
Close
Moment editor
Save
Living Room
Actions
1 of 60
A
Add actions
B
Delete
4. Tap Save, to save the changes.
Deleting a moment
1. On the Home page, tap . 2. Go to Moments, locate the moment you want to delete and tap .
DUG_Underfloor Heating Connection Strip_WH-03
19
Wiser Underfloor Heating Connection Strip
3. On the Moment editor page, tap Delete (A) and then tap Ok (B).
Close
Moment editor
Save
Living Room
Actions
1 of 60
Moments
Are you sure you want to delete this Moment?
CANCEL OK
B
Add actions
Delete
A
Creating an automation
An automation allows you to group multiple actions that are usually done
together, triggered automatically or at scheduled times. By using the Wiser
app, you can create automations based on your needs. To create an automation:
1. On the Home page, tap .
2. Go to Automation > to create an automation. NOTE: Max. 10 automations can
be added.
3. Tap If (A) and select any of the following conditions (B): All
conditions: This triggers an action only when all conditions are met. Any
condition: This triggers an action when at least one condition is met.
Close
New automation
Save
e.g. Good Morning
A
If
When
Then
Conditions are met All conditions
0 of 10
Any condition
B
Start by adding a condition that will trigger your automation.
Add conditions
20
DUG_Underfloor Heating Connection Strip_WH-03
Wiser Underfloor Heating Connection Strip
4. Tap Add conditions and select any of the following (C):
Device status change: Select a device to enable automation. Away Mode:
Enable/Disable away mode to trigger an action.
TIP: Away mode can also be used as a trigger to turn off the lights, dimmer or
closing the shutter etc. For more information refer to Away mode.
Add conditions
Please choose the triggers to activate your automation.
Device status change
E.g. if motion is detected
C
Away Mode
E.g. if away mode is on
5. Tap Device status change > Temperature/Humidity Sensor > Temperature, Set the temperature using sliding bar (D) and select the condition (E) (less than / more than), then tap Set.
Back
Temp bedroom
Set
D °
less than
E
NOTE: · Max. 10 conditions can be added.
· To remove an added condition, swipe left and tap .
DUG_Underfloor Heating Connection Strip_WH-03
21
Wiser Underfloor Heating Connection Strip 6. To set a specific time for your
automation, tap When > Add time and select
any of the following (F): Specific time of the day: Sunrise, Sunset, Custom.
Period of time: Daytime, Night time, Custom.
Add time
F
NOTE: · Max. 10 entries can be added · To remove a specific time, swipe left
and tap .
7. To add an action, tap Then > Add an action and select any of the following
(G): Control a device: Select a devices that you want to trigger. Send
notification: Turn on the notification for the automation. Activate a
moment: Select the moment that you want to trigger.
Add an action
Control a device
G
Activate a moment
22
DUG_Underfloor Heating Connection Strip_WH-03
Wiser Underfloor Heating Connection Strip
8. Tap Control a device > Heating and select any of the following (H):
Boost: Set the duration to increase the temperature by 2° C. Setpoint: Set
the desired temperature.
Select device Please select a device that will activate
All
PleRasaedicahtoorose what you would like
BooBsltind control switch
H
Setpoint
Cancel
9. Tap Setpoint, set the required temperature using vertical sliding bar (I), then tap Set.
Back
Heating
Set
I
NOTE: · Max. 10 actions can be added.
· To remove an action, swipe it left on the action and then tap .
DUG_Underfloor Heating Connection Strip_WH-03
23
Wiser Underfloor Heating Connection Strip
10. Enter the automation name (J). You can choose the cover image that represents your automation by tapping .
Close
New automation
Save
J
If Run this action
When
Then 0 of 10
Add an action
11. Tap Save. Once the automation is saved, it is visible on the Automation tab. Using the (K) you can enable and disable the automation.
Automations
Schedules
Device
K
Example of an automation
This demonstration shows you how to create an automation to turn on the
Heating to 20 °C when the temperature is less than 18 °C.
NOTE: It is mandatory to create two automations. First, switch on the heater
at 22 °C when the room temperature is at 17 °C or lower. Second, switch off
the heater when the room temperature is at 25 °C or above. The room heater
will not turn off automatically until you create another automation.
1. Go to Automation > to create an automation.
2. To add a condition, tap Add Condition > Device status change >
Temperature/Humidity Sensor > Temperature.
24
DUG_Underfloor Heating Connection Strip_WH-03
Wiser Underfloor Heating Connection Strip
3. Set the temperature as 18 °C (A) and the condition as less than (B) and tap Set.
Back
Temp bedroom
Set
A °
B
less than
4. Read the information and tap OK. 5. To add an action, tap Then > Add an
action > Control a device > Heating >
Setpoint. Set the temperature to 20 °C (C), then tap Set.
Back
Heating
Set
C
6. Read the information and tap OK. 7. Enter the name of the automation.
TIP: You can choose the cover image that represents your automation by tapping
.
DUG_Underfloor Heating Connection Strip_WH-03
25
Wiser Underfloor Heating Connection Strip
8. Tap Save. Once the automation is saved, it is visible on the Automation tab.
Automations
Schedules
Device
D
NOTE: You can enable or disable saved automations on the Automations tab by using (D).
26
DUG_Underfloor Heating Connection Strip_WH-03
Wiser Underfloor Heating Connection Strip
Editing an automation
1. On the Home page, tap . 2. Go to Automation, tap the automation you want
to edit. 3. On the Edit automation page, you can perform following changes:
· Change the icon . · Rename the automation. · Tap each condition to change
the settings.
To remove a condition, slide the condition towards left and then tap
(A) to delete it. Tap Add conditions (B) to add new condition.
Close
Edit automation
Save
Living Room
If
When
Conditions are met All conditions
Then 1 of 10 Any condition
A
Add conditions
B
Delete automation
4. Tap Save , to save the changes.
Deleting an automation
1. On the Home page, tap . 2. Go to Automation, tap the automation you want to delete.
DUG_Underfloor Heating Connection Strip_WH-03
27
Wiser Underfloor Heating Connection Strip
3. On the Edit automation page, tap Delete automation (A) and read the confirmation message and then tap OK (B).
Close
Edit automation
Save
Living Room
If
When
Conditions are met All conditions
Then 1 of 10 Any condition
Are you Sure?
Your Living Room automation will be deleted and can not be recovered.
CANCEL OK
B
Add conditions
Delete automation
A
Removing the device from the Wiser system
Using the Wiser home app, you can remove the Underfloor Heating from the Wiser
system. To remove the Underfloor Heating:
1. On the Home page, tap . 2. Tap Devices > Underfloor Heating > Delete (A).
Delete
A
Resetting the device
You can reset the Underfloor Heating to the factory default. To reset the
Underfloor Heating:
28
DUG_Underfloor Heating Connection Strip_WH-03
Wiser Underfloor Heating Connection Strip 1. Press and hold the Setup button
for more than 15 seconds. After 15 seconds, the LED flashes red.
2. When the LED stops flashing red, release the setup button. The LED stops
flashing upon successful reset of the Underfloor Heating.
DUG_Underfloor Heating Connection Strip_WH-03
29
LED indications
Normal use
LED LED
Channel 1-6 LEDs
LED status off
dimmy lit
Wiser Underfloor Heating Connection Strip
Behaviour Power plant under voltage Relay open (no call for heat) closed (call
for heat) Delay in relay activation System test / emergency operation
Configuration LED
Connected to the WiFi gateway Attempting to link with the gateway
LED of a channel
Blinking red
No connection with the WiFi gateway
Floor temperature exceeded Channels activated
Heating / cooling LED
Cooling mode Dew sensor activated
Pump LED Boiler LED
Pump activated Boiler activated
Settings
User action
Connection of the control unit for configuration LED from hydraulic floor to
the Wifi gateway.
Press and hold the configuration button for more than 2 s.
Resetting the control unit for hydraulic floor valves.
Press and hold the configuration button for more than 20 s.
Identification of the control unit for valves All the hydraulic floor LEDs
from the application.
LED valves
Configuration LED
LED status Turn signal
/
Red until that all LEDs are flashing
Behaviour The link is implemented. Follow the instructions of the application.
The control unit for hydraulic floor will be removed from the Wiser platform.
Identification
30
DUG_Underfloor Heating Connection Strip_WH-03
Wiser Underfloor Heating Connection Strip
Troubleshooting
Symptom The orange setup LED is flashing.
The red setup LED is flashing.
Heat/Cool LED flashing blue
Output channel LED (S) flashing Green Unable to control temperature or No
temperature input. Control are disabled for a room with UFH strip.
Possible cause
Solution
· Weak or no signal between the Wiser Hub and the underfloor heating.
· Connection has been lost.
Floor temperature limits exceeded.
· Check Hub is online. · Check signal strength.
· Check floor temperature limits. · Check the temperature sensor connection.
Dew detected on manifold
· Check dew sensor fitting · Wait for moisture to evaporate.
Emergency heat is active on those channels.
Cancel emergency heat.
The room has only an Electrical Heating Switch or UFH.
To control climate in this room you need to add a Room thermostat or Connected thermostat to the room.
The room has a UFH strip, but no channels.
To control climate in this room you need to add a UFH channel from your Room or Device screen. Refer Assign channel to the room, page 10.
DUG_Underfloor Heating Connection Strip_WH-03
31
Technical Data
Versions:
Power supply: Zones and devices per system: Ambient temperature: Ambient
humidity: (non condensing) Remote sensor temperature resolution: Without
power: Wireless: Signal Range: Maximum signal strength: Pollution class:
Energy class: Software class: Fuse rating: Relays: Number of 3 W actuators per
channel:
Number of 3 W actuators per device: Rated surge voltage: Terminals (green):
Protection class: Ingress protection: Antenna: Automatic function: Method of
earthing control basic version:
Method of earthing control full version:
Dimensions:
Wiser Underfloor Heating Connection Strip
UFH Heat/Cool (CCTFR6600) UFH Heat (CCTFR6610) UFH Heat/Cool 24 V (CCTFR6620)
230 V / 24 V AC ± 10% 50 Hz Max 6 per zone, max 16 per system, max 32 devices
per system Operating 0 °C to 50 °C, Storage -10 °C to 55 °C Operating 25 % to
85 %, Storage 15 % to 85 %
1 °C Relays normally open 2.4 GHz (Bi-directional, Mesh) 30 m Free space 14
dBm (25 mW) 2 IV = 2% A 3.15 A Normally open 2(1)A Zones 1 and 2…..4 Actuators
Zones 3 and 4…..2 Actuators Zones 5 and 6…..1 Actuators 14 4 kV Screwless for
type Y 0,08-1,5 mm², AWG 16-28 Class II IP30 External antenna (supplied) Not
applicable: the thermostat controls the temperature Device in not earthed.
Double insulated. The device is not earthed. A terminal is provided for an
external earth cable. Double insulated. 305 x 90 x 65 mm (LxHxD)
32
DUG_Underfloor Heating Connection Strip_WH-03
Compliance
Compliance
Compliance information for Green Premium products
Find and download comprehensive information about Green Premium products,
including RoHS compliance and REACH declarations as well as Product
Environmental Profile (PEP) and End-of-Life instructions (EOLI).
https://checkaproduct.se.com/
General information about Green Premium products
Click the link below to read about Schneider Electric’s Green Premium product
strategy. https://www.schneider-electric.com/en/work/support/green-premium/
DUG_Underfloor Heating Connection Strip_WH-03
33
Declaration of Conformity
Compliance
Hereby, Schneider Electric Industries, declares that this product is in compliance with the essential requirements and other relevant provisions of RADIO DIRECTIVE 2014/53/EU. Declaration of conformity can be downloaded on se. com/docs.
Trademarks
This guide makes reference to system and brand names that are trademarks of
their relevant owners.
· Zigbee® is a registered trademark of the Connectivity Standards Alliance.
· Apple® and App Store® are brand names or registered trademarks of Apple Inc.
· Google PlayTM Store and AndroidTM are brand names or registered trademarks
of Google Inc.
· Wi-Fi® is a registered trademark of Wi-Fi Alliance®.
· WiserTM is a trademark and the property of Schneider Electric, its
subsidiaries and affiliated companies.
· Amazon AlexaTM is a trademark of AMAZON TECHNOLOGIES, INC.
· Google HomeTM is a trademark of Google INC.
· Airzone is a trademark of Equip Outdoor Technologies UK Limited.
· Aidoo is a trademark of CORPORACIÓN EMPRESARIAL ALTRA S.L. company.
Other brands and registered trademarks are the property of their respective
owners.
34
DUG_Underfloor Heating Connection Strip_WH-03
Schneider Electric 35 rue Joseph Monier 92500 Rueil Malmaison France + 33 (0)
1 41 29 70 00 www.se.com
As standards, specifications, and design change from time to time, please ask
for confirmation of the information given in this publication.
© 2021 2024 Schneider Electric. All rights reserved. DUG_Underfloor Heating
Connection Strip_WH-03
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>